- Conspectus
- Specificationes
- Descriptio
- Usus
- Installatio
- Guadium pro Solvendis Problematis
- FAQ
- Producta Commendata
Conspectus
Locus originis: |
USA |
Nomen marcae: |
WOODWARD |
Numerus exemplaris: |
9905-021 |
Particularia impaquetandi: |
Originales nova Officina Sigillata |
Tempus solutionis: |
5-7 dies |
Conditiones solutionis: |
T/T |
Vis Supplicandi: |
In stirpe |
Specificationes
|
Formam |
9905-021 |
|
Nomen Producti |
Regulatio Velocitatis pro Distributione Onus |
|
SERIES |
2301A |
|
Fabricator |
WOODWARD |
|
Genus clausurae |
Lamina Metallica |
|
Ingressus Distributionis Onus |
0–6 VDC |
|
Dimensiones |
38,7 × 18,2 × 6 cm |
|
Pondus |
1.86 kg |
|
Current operativa actuantis |
0–200 mA |
|
Operatio directa/conversa |
Inversus |
|
Actuator in serie/unicus |
Unicus |
|
Tempus decelerationis regulabile |
No |
|
Intervalum frequentialis signi velocitatis |
500–1500 Hz, 1000–3000 Hz, 2000–6000 Hz, 4000–12000 Hz |
|
Controller |
Typus tensionis infimae |
|
Operari Potestas Suppedito |
CC: 20–40 Vcc |
Descriptio
Controllus Velocitatis pro Distributione Onus 9905-021 est controllus inversus, ad tensionem infimam pertinens, qui ad seriem 9905 controlli Woodward 2301A pertinet. Series 9905 controlli Woodward 2301A ad distributionem velocitatis et onus generatorum a motoribus primis, ut diesel, benzina, turbinibus vaporis, aut turbinibus gaseis, impulsis, utitur. Huiusmodi motores in hoc manuale collecte motores primi appellantur.
Usus
Plantae Generatorum Diesel Parallelarum: Onus aequilibratum pro pluribus generatoribus durante subitis mutationibus onus certificat.
Plantae Navium Marinarum: Robustum controlum velocitatis et parallelum pro systematibus generatorum auxiliarium et principalium navium praebet.
Plantae Turbinum Gas: Controlum velocitatis isochroni clausi circuitus altissimae praecisionis pro motoribus turbinibus permittit.
Plantae Mobiles Potestatis Emergentis: Stabilem controlum motoris sub fluctuationibus tensionis batteriae in initiis frigidis servat.
Systemata Potestatis Perforationis Petrolei: Velocitatem motoris sub subitis mutationibus onus in asperis ambiantibus perforationis stabilizant
Installatio
Guadium pro Solvendis Problematis
Symptōma defectūs: Motor prīmārius incipere nōn potest, et actuator nōn est in locō incipiendī. (Nota: Si actuator iam in locō incipiendī est, causa fortasse in systemāte ōleī motoris prīmāriī est.)
Causae possibiles et solūtiōnēs
1. Polāritās alimentī inversa aut absēnsia alimentī: Mētīre pinnās intrāns 16(+) et 17(−) contrōllātōris ad vērificandam voltāgem et polāritātem alimentī.
2. Actuator non respondet signo introducto: Mensurae voltagium ex pinis 20(+) et 21(−) controlleris; si signum est sed actuator non movetur, inspiciatur connexio electrica actuatoris. In genere, resistentia interna actuatoris est <50 Ω. Si actuator est plene electricus, causa fortasse in driver est.
FAQ
Q: Quae est currentis operativa actuatoris? 9905-021?
A: Intervalum currentis operativae actuatoris est 0–200 mA.
Q: Quae est modus operativus directus/retrogradus? 9905-021?
A: Modus operativus est retrogradus.
Q: Num 9905-021supportatne tempus decelerationis adiustare?
A: Non, hoc modello non datur adiustatio temporis decelerationis.
Q: Quod genus controlleris est? 9905-021?
A: Hoc instrumentum est controller humilis voltatis.
Q: Quae est voltatio alimentaria operativa? 9905-021?
A: Tensio operativa permittenda est 20–40 Vcc.