Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
ao801 3bse020514r1analog output module-0

For ABB

Home >  Products >  For ABB

AO801 3BSE020514R1 Analog Output Module

  • Overview
  • Specifications
  • Description
  • Environment and certification
  • Applications
  • Features and benefits
  • Diagnostics
  • FAQ
  • Recommended Products
Overview

Place of Origin:

Sweden

Brand Name:

ABB

Model Number:

AO801 3BSE020514R1

Packaging Details:

Original new Factory Sealed

Delivery Time:

5-7 days

Payment Terms:

T/T

Supply Ability:

In stock

Specifications

Model:

AO801 3BSE020514R1

Dimensions:

9.3 x 13.5 x 6 cm

Weight:

0.24 kg

Signal Specification:

0...20 mA, 4...20 mA

Number of Channels:

8

Signal Type:

Unipolar single ended

HART Support:

No

SOE:

No

Redundancy:

No

High Integrity:

No

Intrinsic Safety:

No

Mechanics:

S800L

Resolution:

12 bit

Isolation:

Groupwise isolated from ground

Under/Over Range:

- / +15%

Output Load:

Max 850 Ω

Error:

0.1 %

Temperature Drift:

Typ 30 ppm/°C, Max 50 ppm/°C

Rise Time:

10 µs

Update Cycle Time:

1 ms

Current Limiting:

Short circuit proof current limited output

Maximum Field Cable Length:

600 meters (656 yards)

Rated Insulation Voltage:

50 V

Dielectric Test Voltage:

500 V a.c.

Power Dissipation:

3.8 W

Current Consumption +5 V Modulebus:

70 mA

Current Consumption +24 V Modulebus:

-

Current Consumption +24 V External:

200 mA

Supported Wire Size:

Solid: 0.05-2.5 mm², 30-12 AWG; Stranded: 0.05-1.5 mm², 30-12 AWG

Recommended Torque:

0.5-0.6 Nm

Stripping Length:

6-7.5 mm, 0.24-0.30 inch

Description

The AO801 3BSE020514R1 Analog Output Module has 8 unipolar analog output channels. The module performs selfdiagnostic cyclically. A low internal power supply sets the module in INIT state (no signal from the module).

Environment and certification

CE Mark:

Yes

Electrical Safety:

EN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201

Hazardous Location:

C1 Div 2 cULus, C1 Zone 2 cULus, ATEX Zone 2

Marine Certification:

ABS, BV, DNV, LR

Operating Temperature:

0 to +55 °C (+32 to +131 °F), approvals issued for +5 to +55 °C

Storage Temperature:

-40 to +70 °C (-40 to +158 °F)

Pollution Degree:

Degree 2, IEC 60664-1

Corrosion Protection:

ISA-S71.04: G3

Relative Humidity:

5 to 95 %, non-condensing

Max Ambient Temperature:

55 °C (131 °F), for vertical mounting 40 °C (104 °F)

Protection Class:

IP20 according to IEC 60529

Mechanical Operating Conditions:

IEC/EN 61131-2

EMC:

EN 61000-6-4 and EN 61000-6-2

Overvoltage Categories:

IEC/EN 60664-1, EN 50178

Equipment Class:

Class I according to IEC 61140 (earth protected)

RoHS Compliance:

EU RoHS, UAE RoHS, CN RoHS

WEEE Compliance:

DIRECTIVE/2012/19/EU

Applications

Power plants/electric power stations: Used to regulate boiler feedwater pump frequency converters and damper actuators.

Petrochemical plants: Drive various field control valves (4...20 mA signal) from within the safety control cabinet.

Paper mills: Precisely control the headbox pressure of paper machines and the steam control valves of each drying cylinder.

Fertilizer plants/fine chemical plants: Used to control the speed of dosing pumps and the cooling water flow rate of reactors.

Metallurgical plants/steel mills: Regulate the opening of gaseous fuel valves in the continuous casting or heating furnace control system.

Features and benefits

8 channels of 0...20 mA, 4...20 mA outputs

OSP sets outputs to predetermined state upon error detection

Analog Output is to be short circuit secured to ZP or +24 V

Process and power connection via detachable connectors

Diagnostics

Front LED’s: S(tatus) (run or fault)

Status indication of supervision: Module Error, Module Warning, Channel error

FAQ

Q: What is the AO801 3BSE020514R1?
A: It is a Analog Output Module.

Q: What are the differences between AO801 and AO810?
A: AO810 (3BSE008516R1) supports both 0–20 mA and 4–20 mA current outputs and features enhanced self-diagnostic capabilities, whereas AO801 only supports 4–20 mA output.

Q: Does AO801 3BSE020514R1 support 0–10 V voltage output?
A: No. AO801 3BSE020514R1 is analog output modules only. To obtain a voltage output, an external 500 Ω precision resistor or an AO820 voltage output module is required.

Q: Does AO801 3BSE020514R1 support HART protocol?
A: No. If HART communication is needed, AO845 or AO845A modules should be used instead.

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.