Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
output module -0

For GE

Home >  Products >  For GE

IC693ALG442 Analog Current/Voltage Input/Output module

  • Overview
  • Specifications
  • Description
  • Applications
  • Features
  • Installation in Hazardous Areas
  • FAQ
  • Recommended Products
Overview

Place of Origin:

USA

Brand Name:

GE

Model Number:

IC693ALG442

Packaging Details:

Original new Factory Sealed

Delivery Time:

5-7 days

Payment Terms:

T/T

Supply Ability:

In stock

Specifications

Parameter

Value

Module Name

IC693ALG442 Analog Current/Voltage Input/Output Module

Module Type

Analog Current/Voltage I/O Module

External Supply Voltage Range

20–30 VDC (24 VDC typical)

Power Supply Rejection Ratio

Current: 5 μA/V typical, 10 μA/V maximum; Voltage: 25 mV/V typical, 50 mV/V maximum

Voltage Ripple

10%

Power Consumption

95 mA from internal +5 VDC; 150 mA from external +24 VDC

Update Rate

3 ms

Isolation (Field to Backplane / Frame Ground)

250 VAC continuous; 1500 VAC for 1 minute

Analog Outputs

Two, Single-Ended

Analog Current Output Ranges

0–20 mA, 4–20 mA

Analog Current Output Resolution

0–20 mA: 0.6 μA; 4–20 mA: 0.5 μA

Analog Current Output Absolute Accuracy

±0.1% FS typical @25°C; ±0.25% FS max @25°C; ±0.5% FS over operating temperature

Maximum Compliance Voltage

VUSER –3 V min to VUSER max

User Load

USER = 20 V, max 1350 Ω at VUSER = 30 V

Output Load Capacitance

2000 pF max

Output Load Inductance

1 H max

Analog Current Input Ranges

0–20 mA, 4–20 mA, 4–20 mA Enhanced

Analog Current Input Resolution

5 μA

Analog Current Input Absolute Accuracy

±0.25% FS @25°C; ±0.5% FS over operating temperature

Linearity

<1 LSB

Common Mode Voltage

200 VDC max

Common Mode Rejection

>70 dB at DC; >70 dB at 60 Hz

Cross Channel Rejection

>70 dB from DC to 1 kHz

Input Impedance

250 Ω

Input Filter Response

38 Hz

Description

Analog Current/Voltage Input/Output module, IC693ALG442 provides four differential input channels and two single-ended output channels. Each channel can be configured with the Machine Edition software for one of the following ranges:

▪ 0 to +10 volts (unipolar), default.

▪ -10 to +10 volts (bipolar)

▪ 0 to 20 mA

▪ 4 to 20 mA

Input channels can also be configured for 4 - 20 mA Enhanced mode. This module may be installed in any I/O slot that has a serial connector in an RX3i or Series 90-30 system.

Applications

HVAC and Building Automation: Collects indoor and outdoor temperature and humidity signals, and outputs signals to control fan frequency converters or proportional control valves.

Water Treatment and Environmental Protection Plants: Monitors water tank levels and pH levels, and outputs control signals to regulate the flow rate of dosing pumps based on PID algorithms.

Packaging Machinery and Conveying Systems: Receives displacement sensor signals and outputs commands to adjust the speed of servo motors.

Boiler and Thermal Control: Monitors steam pressure and adjusts the opening of gas butterfly valves.

Features

Outputs can be configured to either Hold Last State or to reset to the low end of their range if system power is interrupted. Outputs can also be configured to operate in ramp mode on command from the application program. In ramp mode, the output channel transitions to a new value over a period of time, rather than taking the new value immediately. High and low alarm limits can be set for all input channels and an open-wire fault (current output modes) can be reported to the CPU for each output channel. ALG442 modules in RX3i racks support firmware upgrades in the field.

Installation in Hazardous Areas

The following information is for products bearing the UL marking for Hazardous Areas or ATEX marking

for explosive atmospheres:

1 EQUIPMENT LABELED WITH REFERENCE TO CLASS I, GROUPS A, B, C & D, DIV. 2 HAZARDOUS AREAS IS SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C, D OR NON-HAZARDOUS LOCATIONS ONLY

2 WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2;

3 WARNING - EXPLOSION HAZARD - WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES; AND

4 WARNING - EXPLOSION HAZARD - DO NOT CONNECT OR DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS.

FAQ

Q: Does the IC693ALG442 come with a warranty?

A: Yes, the IC693ALG442 includes a 1-year .

Q: What is the supported number of input and output channels of the IC693ALG442?

A: The IC693ALG442 has four (4) differential inputs and two (2) single-ended outputs.

Q: What are the supported input signals of the IC693ALG442?

A: Compatible input signals are 0 to +10 volts (unipolar), –10 to +10 volts (bipolar), 0 to 20 mA, 4 to 20 mA, and 4 to 20 mA Enhanced input signals.

Q: Does this module require an external power supply to operate?

A: Yes, a 24 VDC external power supply is needed to operate this module.

Get a Free Quote