Siemens WF 721 6FM1721-3AA20 Positioning Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Product Overview
- Key Functions
- Official Specifications
- Frequently Asked Questions
- Compatibility & Ordering Notes
- Hot Selling Models
- Recommended Products
Overview
Siemens · WF 721
6FM1721-3AA20 Positioning Module
Siemens 6FM1721-3AA20 is a WF 721 positioning module for closed-loop machine-axis control with command-value output, incremental or serial encoder feedback and fast digital I/O.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6FM1721-3AA20 |
| Product Type | Closed-loop positioning module |
| Core Function | Processes command and actual values for one controlled machine axis |
| Application or Compatible Series | Documented SIMATIC S5 and SIMATIC S7-400 rack configurations |
Rack Integration
Confirm the permitted CPU, rack and adapter-casing arrangement for the installed PLC.
Encoder Interface
Match the incremental or supported serial encoder format, wiring and supply.
Drive Signals
Preserve command-value, controller-enable and feedback connections to the servo drive.
Product Overview
Siemens 6FM1721-3AA20 is a WF 721 positioning module for closed-loop machine-axis control with command-value output, incremental or serial encoder feedback and fast digital I/O.
The module evaluates position feedback and supplies command values for a controlled drive axis. Incremental encoders or supported serial encoders can provide actual-position feedback. Dedicated digital inputs and outputs handle drive-ready, enable and machine-control signals.
Key Functions
Closed-Loop Axis Control
The module evaluates position feedback and supplies command values for a controlled drive axis.
Encoder Flexibility
Incremental encoders or supported serial encoders can provide actual-position feedback.
Fast Machine I/O
Dedicated digital inputs and outputs handle drive-ready, enable and machine-control signals.
Official Specifications
| Internal Bus Supply | 5 V DC nominal |
|---|---|
| Internal Supply Static Limits | 4.85 to 5.25 V DC |
| Module Current Consumption | 1.0 A without encoder |
| Maximum Encoder Supply Current | 0.3 A |
| External Output Supply | 24 V DC nominal; 20 to 30 V DC static range |
| Dynamic Undervoltage Limit | 14.25 V for 5 ms with 10 s recovery time |
| Dynamic Overvoltage Limit | 35 V for 500 ms with 50 s recovery time |
| Analog Command-Value Range | -10 to +10 V DC |
| Permitted Analog Load Current | 0 to 2 mA |
| Binary Input High Range | 13 to 33 V DC |
| Binary Output High Range | 15 to 33 V DC |
| Binary Input Current Range | 0 to 5 mA |
| Binary Output Current Range | 0 to 500 mA |
| Binary Input Low Range | -2 to +4.5 V DC |
| Binary Output Low Range | 0 to +2.5 V DC |
| Incremental Encoder Frequency Limit | 250 kHz |
| Serial Encoder Data Rate | 125 kbit/s |
| Reliability at 25 °C | MTBF 6.65 years |
| Approximate Weight | 0.6 kg |
| Operating Temperature | 0 to 55 °C |
Frequently Asked Questions
Which feedback devices can I connect to 6FM1721-3AA20?
The axis can use an incremental encoder or a supported serial encoder with the required data format and supply.
How fast may the incremental encoder signal be for 6FM1721-3AA20?
The specified incremental encoder input limit is 250 kHz.
What command signal does 6FM1721-3AA20 send to the drive?
The analog command-value interface operates across a -10 to +10 V DC range.
Can 6FM1721-3AA20 be installed in an S7-400 rack?
The positioning module can operate in documented S7-400 arrangements that use the required adapter casing and interface configuration.
How should encoder wiring be routed for 6FM1721-3AA20?
Use shielded twisted-pair conductors and maintain the documented grounding and potential-equalization scheme.
Which external supply is required by 6FM1721-3AA20 outputs?
The digital-output circuitry requires a nominal 24 V DC source within the 20 to 30 V static range.
What should I retain before exchanging 6FM1721-3AA20?
Record the rack address, machine data, encoder settings, drive interface and axis commissioning values before removal.
Compatibility & Ordering Notes
Compatibility Checklist
- Verify the permitted SIMATIC CPU, rack and interface-module arrangement for the installed project.
- Preserve axis machine data, address settings and drive-ready or controller-enable logic.
- Reconnect the encoder with the same signal format, shielding and potential-equalization layout.