Overview
SIMATIC ET 200S

6ES7134-4GB11-0AB0 SIMATIC ET 200S 2AI Standard Current Input Module

A 15 mm two-channel current input module for four-wire transmitters, with ±20 mA and 4–20 mA ranges and configurable digital smoothing.

At a Glance

Brand Siemens
Model 6ES7134-4GB11-0AB0
Product Type Analog current input electronics module
Core Function Converting transmitter currents into digital process values
Application ET 200S analog signal acquisition

Acquire current transmitter signals

Two inputs accept ±20 mA or 4–20 mA with a nominal 50 Ω input resistance.

Filter changing measurements

Digital smoothing is selectable in four stages, from one cycle to 64 cycles.

Identify measurement faults

The module provides group fault and overflow/underflow diagnostics, with wire-break detection for the 4–20 mA range.

Product Overview

6ES7134-4GB11-0AB0 acquires two analog current signals in an ET 200S station. The Standard electronics module accepts bipolar ±20 mA signals and unipolar 4–20 mA transmitter loops.

Integrating conversion and selectable digital filtering adapt the acquired values to the signal dynamics. A group-fault LED and measurement diagnostics help distinguish loop faults from valid process values.

Ordering focus: Match the four-wire transmitter wiring, selected current range and ET 200S terminal arrangement before ordering.
Key Functions

Acquire current transmitter signals

Two inputs accept ±20 mA or 4–20 mA with a nominal 50 Ω input resistance.

Filter changing measurements

Digital smoothing is selectable in four stages, from one cycle to 64 cycles.

Identify measurement faults

The module provides group fault and overflow/underflow diagnostics, with wire-break detection for the 4–20 mA range.

Official Specifications
Number of current inputs 2
Power-module supply 24 V DC from L+
Maximum L+ current without load 30 mA
Maximum backplane current 10 mA at 3.3 V DC
Typical dissipation 0.6 W
Process address allocation 4 bytes
Current ranges and input resistance ±20 mA and 4–20 mA; 50 Ω
Maximum permissible input current 40 mA destruction limit
Shielded signal cable length Maximum 200 m
Measurement principle Integrating
Resolution including sign and overrange 14 bits at ±20 mA; 13 bits at 4–20 mA
Integration times and rejection frequencies 16.7/20 ms; 60/50 Hz
Per-channel conversion time 55/65 ms
Digital smoothing factors 1, 4, 32 or 64 times the cycle time
Operational current error limit ±0.6% of input range over the full temperature range
Basic current error at 25 °C ±0.4% of input range
Wire-break detection range 4–20 mA only
Channel isolation arrangement Inputs isolated from the backplane; no isolation between channels or from L+
Insulation test voltage 500 V DC
Module dimensions and approximate weight 15 × 81 × 52 mm; 40 g
Frequently Asked Questions

Can 6ES7134-4GB11-0AB0 measure a bipolar current signal?

The module accepts currents from −20 mA to +20 mA.

Which transmitter arrangement is intended for 6ES7134-4GB11-0AB0?

The module is intended for four-wire transmitters.

Will 6ES7134-4GB11-0AB0 detect a broken wire on the ±20 mA range?

Wire-break detection is available only on the 4–20 mA range.

How can I reduce measurement fluctuations with 6ES7134-4GB11-0AB0?

Select one of the four digital smoothing stages corresponding to 1, 4, 32 or 64 cycle times.

How much process data should I reserve for 6ES7134-4GB11-0AB0?

The module occupies four bytes of process address space.

Are the two input channels of 6ES7134-4GB11-0AB0 isolated from one another?

The channels are not isolated from one another, although they are isolated from the backplane bus.

How far can shielded current wiring run from 6ES7134-4GB11-0AB0?

Shielded signal cables can be up to 200 m long.

Compatibility & Ordering Notes
Before ordering 6ES7134-4GB11-0AB0: Match the four-wire transmitter wiring, selected current range and ET 200S terminal arrangement before ordering.

Before installation

  • Configure either the ±20 mA or 4–20 mA range to match each transmitter.
  • Account for the 50 Ω input resistance when designing the signal loop.
  • Allow for the active-channel count and conversion time when evaluating the station measurement cycle.
  • Use the SF indication together with group, range and wire-break diagnostics during fault finding.
Hot Selling Models
32.21.004
4315.520
M200-PB1
3RP2535-1AW30
KFD2-CR-Ex1.30-300
3NA3244
33115
3SE7120-2DD01
MGPM16-20
90-2SD-D/LA
8000-88049-3570300
46B/44.31-S12 50109375
3SU1801-0NA00-2AC2
M9F42306
3SU1801-0NB00-2AA2

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.