- Configure either the ±20 mA or 4–20 mA range to match each transmitter.
- Account for the 50 Ω input resistance when designing the signal loop.
- Allow for the active-channel count and conversion time when evaluating the station measurement cycle.
- Use the SF indication together with group, range and wire-break diagnostics during fault finding.
6ES7134-4GB11-0AB0 SIMATIC ET 200S 2AI Standard Current Input Module
A 15 mm two-channel current input module for four-wire transmitters, with ±20 mA and 4–20 mA ranges and configurable digital smoothing.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7134-4GB11-0AB0 |
| Product Type | Analog current input electronics module |
| Core Function | Converting transmitter currents into digital process values |
| Application | ET 200S analog signal acquisition |
Acquire current transmitter signals
Two inputs accept ±20 mA or 4–20 mA with a nominal 50 Ω input resistance.
Filter changing measurements
Digital smoothing is selectable in four stages, from one cycle to 64 cycles.
Identify measurement faults
The module provides group fault and overflow/underflow diagnostics, with wire-break detection for the 4–20 mA range.
Product Overview
6ES7134-4GB11-0AB0 acquires two analog current signals in an ET 200S station. The Standard electronics module accepts bipolar ±20 mA signals and unipolar 4–20 mA transmitter loops.
Integrating conversion and selectable digital filtering adapt the acquired values to the signal dynamics. A group-fault LED and measurement diagnostics help distinguish loop faults from valid process values.
Key Functions
Acquire current transmitter signals
Two inputs accept ±20 mA or 4–20 mA with a nominal 50 Ω input resistance.
Filter changing measurements
Digital smoothing is selectable in four stages, from one cycle to 64 cycles.
Identify measurement faults
The module provides group fault and overflow/underflow diagnostics, with wire-break detection for the 4–20 mA range.
Official Specifications
| Number of current inputs | 2 |
|---|---|
| Power-module supply | 24 V DC from L+ |
| Maximum L+ current without load | 30 mA |
| Maximum backplane current | 10 mA at 3.3 V DC |
| Typical dissipation | 0.6 W |
| Process address allocation | 4 bytes |
| Current ranges and input resistance | ±20 mA and 4–20 mA; 50 Ω |
| Maximum permissible input current | 40 mA destruction limit |
| Shielded signal cable length | Maximum 200 m |
| Measurement principle | Integrating |
| Resolution including sign and overrange | 14 bits at ±20 mA; 13 bits at 4–20 mA |
| Integration times and rejection frequencies | 16.7/20 ms; 60/50 Hz |
| Per-channel conversion time | 55/65 ms |
| Digital smoothing factors | 1, 4, 32 or 64 times the cycle time |
| Operational current error limit | ±0.6% of input range over the full temperature range |
| Basic current error at 25 °C | ±0.4% of input range |
| Wire-break detection range | 4–20 mA only |
| Channel isolation arrangement | Inputs isolated from the backplane; no isolation between channels or from L+ |
| Insulation test voltage | 500 V DC |
| Module dimensions and approximate weight | 15 × 81 × 52 mm; 40 g |
Frequently Asked Questions
Can 6ES7134-4GB11-0AB0 measure a bipolar current signal?
The module accepts currents from −20 mA to +20 mA.
Which transmitter arrangement is intended for 6ES7134-4GB11-0AB0?
The module is intended for four-wire transmitters.
Will 6ES7134-4GB11-0AB0 detect a broken wire on the ±20 mA range?
Wire-break detection is available only on the 4–20 mA range.
How can I reduce measurement fluctuations with 6ES7134-4GB11-0AB0?
Select one of the four digital smoothing stages corresponding to 1, 4, 32 or 64 cycle times.
How much process data should I reserve for 6ES7134-4GB11-0AB0?
The module occupies four bytes of process address space.
Are the two input channels of 6ES7134-4GB11-0AB0 isolated from one another?
The channels are not isolated from one another, although they are isolated from the backplane bus.
How far can shielded current wiring run from 6ES7134-4GB11-0AB0?
Shielded signal cables can be up to 200 m long.