Overview
SIEMENS SIMATIC ET 200S

6ES7132-4HB00-0AB0 SIMATIC ET 200S 2RO NO Relay Output Module

A two-channel normally open relay module for loads up to 120 V DC or 230 V AC, with a 24 V DC module supply and temperature-dependent current limits.

At a Glance

Brand Siemens
Model 6ES7132-4HB00-0AB0
Product Type Relay output module
Core Function Isolated switching of field loads
Application ET 200S 24 V DC potential groups

Isolated relay contacts

The two relay channels are electrically isolated from each other and from the backplane.

Temperature-dependent current

Each output permits up to 5 A at 50 °C and up to 4 A at 60 °C.

External output protection

The relay outputs need external 6 A fuse protection.

Product Overview

6ES7132-4HB00-0AB0 switches two field circuits through normally open relay contacts in an ET 200S station.

Its module electronics require a 24 V DC potential group even when the isolated relay contacts switch an AC load, and the selected load voltage and category determine contact life.

Ordering focus: Keep the relay module in a 24 V DC supply group, retain the product-level-dependent bridging arrangement and provide the required external output fuses.
Key Functions

Switch AC or DC field loads

The isolated relay-contact arrangement accepts loads up to 120 V DC or 230 V AC within the permitted switching capacity.

Separate the two output circuits

The relay channels are electrically isolated from one another and from the module supply and backplane.

Indicate output state

A green LED for each channel shows its commanded state without a module diagnostic function.

Official Specifications
Output contact arrangement 2 normally open relay outputs
Rated module-electronics supply 24 V DC
Maximum switched load voltage 120 V DC or 230 V AC
Maximum channel current by temperature 5 A up to +50 °C; 4 A up to +60 °C
Minimum switching load 17 V and 8 mA
Maximum current from L+ 30 mA
Typical module power loss 0.6 W
Maximum load-cable length 600 m unshielded; 1,000 m shielded
Relay isolation Between channels and between outputs, module supply and backplane
Output-to-bus and output-to-supply isolation test 1,500 V AC
Supply-to-backplane isolation test 500 V DC
Maximum switching frequencies 2 Hz resistive or lamp loads; 0.5 Hz inductive loads
External output fuse 6 A required
Internal inductive-voltage limitation None
Parallel output connection Not permitted for redundancy or current increase
Status indication Green LED per channel
Dimensions (W × H × D) 15 × 81 × 52 mm
Approximate module weight 50 g
Frequently Asked Questions

May I put 6ES7132-4HB00-0AB0 in an ET 200S power group supplied with 230 V AC?

No, the module electronics must be supplied from a 24 V DC potential group.

Can each output of 6ES7132-4HB00-0AB0 carry 5 A at an ambient temperature of 60 °C?

No, the permitted channel current at 60 °C is limited to 4 A.

Do I need a fuse outside 6ES7132-4HB00-0AB0 for the relay outputs?

Yes, each relay output requires external 6 A fuse protection.

Can I parallel the two contacts of 6ES7132-4HB00-0AB0 to increase load current?

No, parallel output connection is not permitted for current increase or redundant load control.

Can I mix an SELV circuit with a non-SELV circuit on the two channels of 6ES7132-4HB00-0AB0?

No, when one channel carries SELV or PELV low voltage, the other channel must also carry SELV or PELV low voltage.

What wiring difference should I account for when replacing an earlier product level of 6ES7132-4HB00-0AB0?

From product level 2 the internal bridge between terminals 2 and 6 is absent and any required replacement bridge is made externally between terminals 3 and 7.

Can 6ES7132-4HB00-0AB0 switch a 5 V low-current signal directly?

No, the specified minimum switching load is 17 V and 8 mA.

Compatibility & Ordering Notes
Before ordering 6ES7132-4HB00-0AB0: Retain the 24 V DC supply group, external fuses and correct product-level bridging, and select the relay load from its voltage, utilization category and temperature limit.

Compatibility Checklist for 6ES7132-4HB00-0AB0

  • Apply external 6 A output fuse protection.
  • Use a maximum 4 A per channel at +60 °C.
  • Preserve SELV/PELV separation across both channels.
  • Review the bridge arrangement when changing product level.
Hot Selling Models
8000-84070-0000000
6ES54604UA13
A9D32606
BOS-74K-UU-1FR-BO-Z-S49
50-466
6ES7648-2AG20-0GA0
6ES7132-6BF01-0AA0
XS1M12DA210D
LR2K0308 023044
3RV1021-4BA15
ISE30-T1-65
284684 51126490
M08EE-PSC20B-S49G-003
NBC-R4AC-R4AC-IE8A
8MBM8-3P2-5/S1117

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.