- Appliare protectionem fusibilis externi 6 A pro output.
- Usare maximum 4 A per canallem ad +60 °C.
- Servare separationem SELV/PELV trans utrumque canallem.
- Examinare arrangementum pontis quando mutatur gradus producti.
6ES7132-4HB00-0AB0 SIMATIC ET 200S 2RO NO Modulus outputus rellay
Modulus rellay bi-canalis, apertus normaliter, pro oneribus usque ad 120 V DC aut 230 V AC, cum alimentatione moduli 24 V DC et limitibus currentis dependentibus a temperatura.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7132-4HB00-0AB0 |
| Typus Producti | Modulus Output Relais |
| Functio principalis | Commutatio isolata onerum campestrium |
| Applicatio | ET 200S gruppi potentialis 24 V DC |
Contactus rellay isolati
Duo canales rellay sunt isolati electricamente inter se et ab arcula dorsali.
Currentis dependentia a temperatura
Unusquisque outputus permittit usque ad 5 A ad 50 °C et usque ad 4 A ad 60 °C.
Protectio externa outputus
The relay outputs need external 6 A fuse protection.
Product Overview
6ES7132-4HB00-0AB0 switches two field circuits through normally open relay contacts in an ET 200S station.
Its module electronics require a 24 V DC potential group even when the isolated relay contacts switch an AC load, and the selected load voltage and category determine contact life.
Key Functions
Switch AC or DC field loads
The isolated relay-contact arrangement accepts loads up to 120 V DC or 230 V AC within the permitted switching capacity.
Separate the two output circuits
The relay channels are electrically isolated from one another and from the module supply and backplane.
Indicate output state
A green LED for each channel shows its commanded state without a module diagnostic function.
Official Specifications
| Output contact arrangement | 2 normally open relay outputs |
|---|---|
| Rated module-electronics supply | 24 V DC |
| Maximum switched load voltage | 120 V DC or 230 V AC |
| Maximum channel current by temperature | 5 A up to +50 °C; 4 A up to +60 °C |
| Minimum switching load | 17 V and 8 mA |
| Maxima Currus ab L+ | 30 mA |
| Perdita de Potentia Typical del Modulo | 0,6 W |
| Maximum load-cable length | 600 m non schermati; 1 000 m schermati |
| Isolatio relais | Inter canales et inter output, suppletio moduli et planum dorsale |
| Examinatio isolationis inter output et bus, necnon inter output et suppletionem | 1 500 V AC |
| Examinatio isolationis inter suppletionem et planum dorsale | 500 V DC |
| Frequentias maximas de commutatione | onus resistivum aut lamparum 2 Hz; onus inductivum 0.5 Hz |
| Fusibilis externus output | 6 A requiruntur |
| Limitatio interna tensionis inductivae | Nullus |
| Coniunctio output parallela | Non permittitur pro redundantia aut incremento currentis |
| Indicatio status | LED Viridis per Canal |
| Dimensiones (L × H × D) | 15 × 81 × 52 mm |
| Pondus Moduli Approximatum | 50 g |
Quaestiones Frequenter Rogatae
Possumne ponere 6ES7132-4HB00-0AB0 in gruppus potentiae ET 200S qui 230 V AC supplet?
Non, electronica moduli ex gruppus potentiae 24 V DC suppleri debet.
Potestne unumquodque output 6ES7132-4HB00-0AB0 5 A ad temperaturam ambientem 60 °C ferre?
Non, currentis per canalem permisus ad 60 °C ad 4 A limitatur.
Necesse estne mihi fusibile extra 6ES7132-4HB00-0AB0 pro output relais?
Ita, unumquodque output relais protectione fusibilis externi 6 A indiget.
Possumne duos contactus 6ES7132-4HB00-0AB0 in parallelum coniungere ut currentem oneris augerem?
Non, coniunctio output in parallelum non permittitur ad augmentum currentis vel ad controllem oneris redundans.
Possumne circuitum SELV cum circuitu non-SELV in duobus canalibus 6ES7132-4HB00-0AB0 miscere?
Non, si unus canalis SELV vel PELV tensionem bassam gerit, alter canalis etiam SELV vel PELV tensionem bassam gerere debet.
Quae differentia in connexione observanda est, si productum prius gradus 6ES7132-4HB00-0AB0 substituitur?
A gradu 2 interne pontis inter terminales 2 et 6 non est; igitur, si pontis substitutio necessaria est, externus inter terminales 3 et 7 faciendus est.
Num 6ES7132-4HB00-0AB0 directe signum 5 V parvae currentis commutare potest?
Non, minimum oneris commutandi specificatum est 17 V et 8 mA.