Overview
Place of Origin: |
USA |
Brand Name: |
GE |
Model Number: |
IC695CMM004 |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
5-7 days |
Payment Terms: |
T/T |
Supply Ability: |
In stock |
Specifications
|
Model: |
IC695CMM004 |
|
Dimensions (HxWxD): |
3.5 x 13 x 13.6 cm |
|
Weight: |
0.2 kg |
|
Module Type: |
RX3i Serial Communication Module |
|
Number of Serial Ports: |
4 independent serial ports |
|
Connector Type: |
RJ-45 |
|
Max Modules per CPU: |
6 in main CPU backplane |
|
Power Consumption @ 3.3Vdc: |
0.7 Amps maximum |
|
Power Consumption @ 5.0Vdc: |
0.150 Amps maximum |
|
LED Indicators: |
Module OK, Port Fault, Port Status (2 or 4) |
|
Port Type: |
RS-232 or RS-485/422 (4-wire full duplex / 2-wire half-duplex) |
|
Flow Control (RS-232): |
Hardware (RTS/CTS, RFR/CTS) or None |
|
Baud Rates: |
1200, 2400, 4800, 9600, 19.2K, 38.4K, 57.6K, 115.2K |
|
Parity: |
Even, Odd, None |
|
Data Bits: |
7, 8 |
|
Stop Bits: |
1, 2 |
|
Operating Temperature: |
0°C to +60°C |
|
Input Impedance RS-485/422: |
Zin > 96 kΩ |
|
Input Impedance RS-232: |
3 kΩ < Zin < 7 kΩ |
|
Maximum Overvoltage: |
±25V |
|
Channel-to-Channel Crosstalk: |
–55dB minimum |
|
Isolation Port to Backplane / Frame Ground: |
250Vac continuous; 1500Vac 1 min; 2550Vdc 1 sec |
|
Isolation Port-to-Port: |
500Vdc continuous; 710Vdc 1 min |
Description
The IC695CMM004 is a serial communication module from the PACsystem RX3i product family that is manufactured by Automation, formerly by GE. This provides Four (4) individually operating and isolated Serial ports using RJ45 connector. Each port of the module supports MODBUS Master, MODBUS Slave, CCM Slave, DNP3 Master, DNP3 Slave, or Serial I/O protocol. The IC695CMM004 has selectable baud rates such as 1200, 2400, 4800, 9600, 19.2K, 38.4K, 57.6K, 115.2K and hardware handshaking for RS232 setting such as RTS/CTS, RFR/CTS. The serial interfaces may be set to RS232 for point to point communication and RS422 / RS485 for daisy-chain, multi-drop communication topology. Up to Six (6) serial communication modules may be hosted by a single RX3i CPU. With this, up to a maximum of 24 Serial ports may be enabled and operated simultaneously by a single controller. This module can be used to communicate with Power metering devices, substation devices, Variable Frequency Drives (VFD), gateways, protocol converters and other devices. The IC695CMM004 is capable of reporting module error locally and to the CPU. For local indication, the Module OK LED may blink Once to depict watchdog expired; Two (2) for RAM error; Six (6) for invalid CPU configuration; Seven (7) for CPU heartbeat failure and Eight (8) for failure to get semaphore. Port isolation is rated at 500Vdc continuous and 710Vdc for one minute while the module’s Port to backplane and frame ground isolation rating is 250 VAC continuous and 1500 VAC for 1 minute and 2550 VDC for 1 second.
Applications
Automated Manufacturing Plants (Automotive/Electronics): Connects multiple barcode scanners, printers, or weighing instruments, uploading production data to the PLC in real time.
Water Treatment/Environmental Protection Plants: Acts as a Modbus master station, collecting data from distributed electromagnetic flow meters, turbidity meters, and frequency converters.
Food Processing Plants: Controls third-party serial devices such as inkjet printers and metal detectors on the packaging line.
Installation
Installation in Hazardous Locations:
Equipment labeled with reference to Class I, Groups A, B, C & D, Div. 2 hazardous locations is suitable for use in Class I, Division 2, Groups A, B, C, D or non-hazardous locations only.
Warning – Explosion hazard – Substitution of components may impair suitability for Class I, Division 2.
Warning – Explosion hazard – When in hazardous locations, turn off power before replacing or wiring modules.
Warning – Explosion hazard – Do not connect or disconnect equipment unless power has been switched off or the area is known to be nonhazardous.
FAQ
Q: Does the IC695CMM004 come with a warranty?
A: Yes, the IC695CMM004 includes a 1-year warranty.
Q: What is the difference between IC695CMM002 and IC695CMM004?
A: The IC695CMM002 has two (2) serial ports while the IC695CMM004 has four (4) serial ports.
Q: What is the backplane power requirement of the IC695CMM004?
A: The IC695CMM004 has backplane current consumption of 0.7 Amps maximum @ 3.3Vdc and 0.150 Amps maximum @ 5.0Vdc.
Q: How many ports does the IC695CMM004 have?
A: The IC695CMM004 has four (4) serial ports.