Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es7134 6hd01 0ba1 simatic et 200sp ai 4xu i 2 wire st module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7134-6HD01-0BA1 SIMATIC ET 200SP AI 4xU/I 2-wire ST Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIMATIC ET 200SP • Standard Analog Inputs

6ES7134-6HD01-0BA1 SIMATIC ET 200SP AI 4xU/I 2-wire ST Module

Four differential voltage/current inputs with up to 16-bit conversion, configurable smoothing and module diagnostics.

At a Glance

Brand Siemens
Model 6ES7134-6HD01-0BA1
Product Type Analog input module
Core Function Acquisition of voltage and two-wire current transmitter signals
Application Distributed process value acquisition in ET 200SP stations

Voltage and current channels

Four differential channels accept 0–10 V, 1–5 V, ±10 V, ±5 V, 0–20 mA or 4–20 mA according to parameterization.

Configurable measurement filtering

Selectable 16.6, 50 or 60 Hz suppression and four smoothing levels balance interference rejection and response time.

Module-level diagnostics

Supply monitoring, 4–20 mA wire-break detection and range diagnostics support commissioning and maintenance of analog loops.

Product Overview

6ES7134-6HD01-0BA1 acquires four differential analog signals in an ET 200SP station using Sigma-Delta conversion.

Voltage ranges include bipolar and unipolar signals, while two-wire current transmitter operation supports loop measurements with a short-circuit-protected transmitter supply.

Ordering focus: Match BaseUnit A0 or A1, CC03 terminal identification, the selected voltage/current range and the engineering support for the installed firmware.
Key Functions

Voltage and current channels

Four differential channels accept 0–10 V, 1–5 V, ±10 V, ±5 V, 0–20 mA or 4–20 mA according to parameterization.

Configurable measurement filtering

Selectable 16.6, 50 or 60 Hz suppression and four smoothing levels balance interference rejection and response time.

Module-level diagnostics

Supply monitoring, 4–20 mA wire-break detection and range diagnostics support commissioning and maintenance of analog loops.

Official Specifications
Analog input channels 4 differential inputs
Voltage ranges 0–10 V, 1–5 V, -10 to +10 V and -5 to +5 V
Current ranges 0–20 mA and 4–20 mA
Resolution 15 bits for unipolar ranges; 16 bits including sign for bipolar ranges
Voltage input resistance 120 kΩ
Current input resistance 100 Ω plus approximately 0.7 V diode forward voltage
Measurement method Sigma-Delta
Conversion time per channel 180, 60 or 50 ms
Interference suppression 16.6, 50 or 60 Hz
Smoothing factors 1, 4, 8 or 16 times conversion time
Rated supply and range 24 V DC; 19.2–28.8 V DC
Current consumption Rated 30 mA; maximum 117 mA
Typical power loss 0.85 W
Transmitter supply capacity 20 mA per channel; up to 50 mA for less than 10 s
Process data 8 bytes plus 1 byte of quality information
Basic error at 25 °C ±0.3% for voltage and current
Operating error over temperature ±0.5% for voltage and current
Maximum shielded cable length 1,000 m for current; 200 m for voltage
Dimensions (W × H × D) 15 × 73 × 58 mm
Weight Approximately 31 g
Frequently Asked Questions

Can 6ES7134-6HD01-0BA1 read a bipolar ±10 V signal?

The -10 to +10 V range is supported with 16-bit resolution including the sign.

Will 6ES7134-6HD01-0BA1 detect a broken 0–20 mA loop?

Wire-break diagnostics apply to the 4–20 mA range rather than the 0–20 mA range.

Which BaseUnit should I pair with 6ES7134-6HD01-0BA1?

Use a compatible type A0 or A1 BaseUnit and the CC03 terminal identification for the selected two-wire connection.

Why does stronger smoothing slow the response of 6ES7134-6HD01-0BA1?

The highest smoothing setting uses sixteen times the conversion time, increasing the settling time of a changed input value.

How much address space is required by 6ES7134-6HD01-0BA1?

Reserve eight bytes for analog values and one additional byte when quality information is used.

Can 6ES7134-6HD01-0BA1 generate a process limit-value alarm?

The module provides diagnostic alarms but does not provide a limit-value alarm function.

Can voltage and current channels on 6ES7134-6HD01-0BA1 use equally long field cables?

Shielded current loops may reach 1,000 m while shielded voltage measurement cables are limited to 200 m.

Compatibility & Ordering Notes
Before ordering 6ES7134-6HD01-0BA1: Match BaseUnit A0 or A1, CC03 terminal identification, the selected voltage/current range and the engineering support for the installed firmware.

Before installation

  • Select the correct voltage or current range and wire the compatible A0/A1 BaseUnit accordingly.
  • Use the CC03 identification and account for the additional quality-information byte in the controller project.
  • For the FS22/V3.0.0 data-sheet configuration, engineering support starts with TIA Portal V21.1 or the listed STEP 7 V5.7 updates and HSP0348 V3.0.
  • Enable wire-break diagnosis for 4–20 mA loops and select suppression and smoothing to suit the process response time.
Hot Selling Models
WAGO 285-635
FU-83C
3RA2316-8XB30-1AP0
Finder varitec 9073.0
3RT2015-1AP04-3MA0
KM3712
816-B04-PA-16-602-11 BNS039N
LCR060-24 3041097007TP
4AM3441-4TN00-0B
47.040.038
DAGDV100000
PP-H 2.5/1-M 3210091
FS401M C62CCL562010E0064
iC60N