Siemens 6ES7134-6HD01-0BA1 SIMATIC ET 200SP AI 4xU/I 2-wire ST Module
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Select the correct voltage or current range and wire the compatible A0/A1 BaseUnit accordingly.
- Use the CC03 identification and account for the additional quality-information byte in the controller project.
- For the FS22/V3.0.0 data-sheet configuration, engineering support starts with TIA Portal V21.1 or the listed STEP 7 V5.7 updates and HSP0348 V3.0.
- Enable wire-break diagnosis for 4–20 mA loops and select suppression and smoothing to suit the process response time.
6ES7134-6HD01-0BA1 SIMATIC ET 200SP AI 4xU/I 2-wire ST Module
Four differential voltage/current inputs with up to 16-bit conversion, configurable smoothing and module diagnostics.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7134-6HD01-0BA1 |
| Typus Producti | Modulus Ingressus Analogicus |
| Functio principalis | Acquisition of voltage and two-wire current transmitter signals |
| Applicatio | Distributed process value acquisition in ET 200SP stations |
Voltage and current channels
Four differential channels accept 0–10 V, 1–5 V, ±10 V, ±5 V, 0–20 mA or 4–20 mA according to parameterization.
Filtratio mensurae configurabilis
Selectable 16.6, 50 or 60 Hz suppression and four smoothing levels balance interference rejection and response time.
Module-level diagnostics
Supervisio supply, detectio interruptio fili 4–20 mA et diagnosi ambitus adiuva commissionem et manutenentiam circuituum analogorum.
Product Overview
6ES7134-6HD01-0BA1 Acquirit quattuor signa analogica differentialis in statione ET 200SP utendo conversione Sigma-Delta.
Ambitus tensionis includunt signa bipolaria et unipolaria, dum operatio transmittentis currentis bi-filarii permittit mensuras in circuitu cum suppeditatione transmittentis protecta contra curtum circuitum.
Key Functions
Voltage and current channels
Four differential channels accept 0–10 V, 1–5 V, ±10 V, ±5 V, 0–20 mA or 4–20 mA according to parameterization.
Filtratio mensurae configurabilis
Selectable 16.6, 50 or 60 Hz suppression and four smoothing levels balance interference rejection and response time.
Module-level diagnostics
Supervisio supply, detectio interruptio fili 4–20 mA et diagnosi ambitus adiuva commissionem et manutenentiam circuituum analogorum.
Official Specifications
| Canali Analogici Input | quattuor ingressus differentiales |
|---|---|
| Intervalla Voltaminis | 0–10 V, 1–5 V, -10 usque +10 V et -5 usque +5 V |
| Intervalla Curris | 0–20 mA et 4–20 mA |
| Resolutio | 15 bit pro ambitibus unipolaribus; 16 bit incluso signo pro ambitibus bipolaribus |
| Résistance d'entrée en tension | 120 kΩ |
| Résistance d'entrée en courant | 100 Ω plus approximative 0.7 V tensio directa diodi |
| Modus mensurationis | Sigma-Delta |
| Tempus Conversionis per Canal | 180, 60 aut 50 ms |
| Suppressio Interferentiae | 16.6, 50 aut 60 Hz |
| Factores lenificationis | Tempus conversionis 1, 4, 8 aut 16 vicibus |
| Valoratus Supplicium et Intervalum | 24 V DC; 19,2–28,8 V DC |
| Consumptio currentis | Nominalis 30 mA; maximum 117 mA |
| Perditio potentiæ typica | 0,85 W |
| Capacitas suppeditationis transmittentis | 20 mA per canal; usque ad 50 mA pro minus quam 10 s |
| Data processus | 8 octeta plus 1 octetum informationis de qualitate |
| Error basicus ad 25 °C | ±0.3% pro voltatione et currente |
| Error operativus super temperaturam | ±0.5% pro voltatione et currente |
| Maxima Longitudo Cavi Scutati | 1 000 m pro currente; 200 m pro tensione |
| Dimensiones (L × H × D) | 15 × 73 × 58 mm |
| Pondus | Circa 31 g |
Quaestiones Frequenter Rogatae
Num 6ES7134-6HD01-0BA1 potest legere signum bipolaris ±10 V?
Intervallo -10 ad +10 V suffragatur cum resolutione 16-bit, signo inclusa.
Num 6ES7134-6HD01-0BA1 detegit circuitum interruptum 0–20 mA?
Diagnostica interrupti fili ad intervallum 4–20 mA magis quam ad intervallum 0–20 mA applicatur.
Quam BaseUnit cum 6ES7134-6HD01-0BA1 coniungere debeat?
Ute un BaseUnit compatibilis de typo A0 aut A1 et identificationem terminalis CC03 pro connexionis duarum filorum electae.
Cur fortior levigatio tardat responsionem 6ES7134-6HD01-0BA1?
Summa levigationis positio usque ad sedecim vicibus tempus conversionis occupat, quod tempus stabilisationis valoris intrantis mutati augent.
Quantum spatii adressionis requirit 6ES7134-6HD01-0BA1?
Reserva octo bytes pro valoribus analogicis et unum byte additivum ubi informationes qualitatis utuntur.
Potestne 6ES7134-6HD01-0BA1 generare allarmum limitis processus?
Modulus allarmos diagnosticos praebet, sed non habet functionem allarmi limitis.
Possuntne canales tensionis et currentis in 6ES7134-6HD01-0BA1 aequalem longitudinem cableorum campestrium habere?
Circuli currentis scutati usque ad 1 000 m extendi possunt, dum cables scutati pro mensura tensionis ad 200 m limitantur.