Siemens SIMODRIVE 611 Universal HRS2 6SN1118-1NJ01-0AA2 One-Axis Resolver Control Board
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Confirm the installed converter belongs to the SIMODRIVE 611 universal platform.
- Match the complete HRS2 -0AA2 suffix and software version 14.2 or later.
- Verify the one-axis power module and resolver feedback execution.
- Record the resolver pole-pair count, resolution and motor feedback wiring.
- Restore the validated speed, torque and positioning parameter set.
- Match any TERMINALS or PROFIBUS-DP option module and its connector assignment.
- Check X441 monitoring-output loading and X471 commissioning-interface wiring.
Siemens · SIMODRIVE 611 universal HRS2
6SN1118-1NJ01-0AA2 One-Axis Resolver Positioning Control Board
Siemens 6SN1118-1NJ01-0AA2 is the SIMODRIVE 611 universal HRS2 one-axis control board for resolver feedback and positioning firmware. It supports high-resolution resolver evaluation, parameterizable analog monitoring outputs, serial commissioning and optional terminal or PROFIBUS-DP expansion.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SN1118-1NJ01-0AA2 |
| Product Type | HRS2 Resolver Drive Control Board |
| Core Function | Closes speed, torque and positioning loops for one drive axis |
| Application or Compatible Series | SIMODRIVE 611 universal power-module systems |
HRS2 Identification
Confirm the final hardware digit 2 because the HRS2 board is tied to the later software baseline rather than the HRS or HR execution.
Resolver Match
Record the motor resolver pole-pair count and feedback wiring before transferring the drive parameter set.
Option-Module Check
Identify whether the installed board uses the TERMINALS option or one of the permitted PROFIBUS-DP option modules.
Product Overview
Siemens 6SN1118-1NJ01-0AA2 is the SIMODRIVE 611 universal HRS2 one-axis control board for resolver feedback and positioning firmware. It supports high-resolution resolver evaluation, parameterizable analog monitoring outputs, serial commissioning and optional terminal or PROFIBUS-DP expansion.
Runs the speed, torque and positioning functions for a resolver-equipped drive axis in the modular converter system. Evaluates one-to-six-pole-pair resolvers at selectable 12-bit or 14-bit resolution. Supports SimoCom U through the serial interface and accepts terminal or PROFIBUS-DP option hardware.
Key Functions
Closed-Loop Motion Control
Runs the speed, torque and positioning functions for a resolver-equipped drive axis in the modular converter system.
High-Resolution Feedback
Evaluates one-to-six-pole-pair resolvers at selectable 12-bit or 14-bit resolution.
Expandable Commissioning Interface
Supports SimoCom U through the serial interface and accepts terminal or PROFIBUS-DP option hardware.
Official Specifications
| HRS2 Software Baseline | Control-board software version 14.2 or later |
|---|---|
| Resolver Pole Pairs | 1 to 6 |
| Resolver Resolution | 12-bit or 14-bit selectable evaluation |
| Resolver Limit Frequency at 12 Bit | 957 Hz for HRS2 |
| Resolver Limit Frequency at 14 Bit | 479 Hz for HRS2 |
| Maximum Speed at 12 Bit | 57,420 r/min with a one-pole-pair resolver |
| Maximum Speed at 14 Bit | Approximately 28,740 r/min with a one-pole-pair resolver |
| Analog Monitoring Outputs | Two freely parameterizable outputs for the active drive at X441 |
| Analog Output Range | -10 V to +10 V |
| Analog Output Current | 3 mA maximum |
| Analog Output Resolution | 8 bits |
| Analog Output Update | Updated in the speed-controller clock cycle |
| Analog Output Protection | Short-circuit proof |
| X441 Connection | 5-pin connector strip; 0.5 mm² maximum conductor cross-section |
| Serial Commissioning Port | X471 can operate as RS232 or RS485 |
| Terminal Option | 6SN1114-0NA00-0AA0 |
| PROFIBUS-DP Options | 6SN1114-0NB00-0AA2 or 6SN1114-0NB01-0AA1 |
| PROFIBUS-DP Board Requirement | Control-board software version 3.1 or later |
Frequently Asked Questions
Which feedback device is required by 6SN1118-1NJ01-0AA2?
Use a resolver with one to six pole pairs and configure its pole-pair count and resolution to match the motor.
How do I commission 6SN1118-1NJ01-0AA2 from a PC?
Connect SimoCom U through X471 in the selected RS232 or RS485 operating mode after disabling pulses as required for safe work.
Which software baseline belongs with 6SN1118-1NJ01-0AA2?
Use the HRS2 control-board baseline of version 14.2 or later and restore the proven drive parameter set.
Can 6SN1118-1NJ01-0AA2 use a PROFIBUS-DP option?
Yes, fit an approved option module and verify its hardware, connector, address and bus configuration before startup.
What should I record before replacing 6SN1118-1NJ01-0AA2?
Back up the drive parameters and record resolver data, option-module type, terminal assignments and firmware level.
How should I use the analog outputs on 6SN1118-1NJ01-0AA2?
Assign the required internal quantities in the parameter set and keep each output within the ±10 V and 3 mA limits.
Can 6SN1118-1NJ01-0AA2 replace a two-axis control board?
No, confirm the one-axis power-module arrangement and resolver execution rather than selecting a board only by the wider product family.