Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens simatic et 200isp 6es7132 7gd00 0ab0 4 do 23 1 v dc 20 ma l shutdown module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIMATIC ET 200iSP 6ES7132-7GD00-0AB0 4 DO 23.1 V DC/20 mA L-Shutdown Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview

Siemens · SIMATIC ET 200iSP

6ES7132-7GD00-0AB0 4 DO 23.1 V DC/20 mA L-Shutdown Electronic Module

Siemens 6ES7132-7GD00-0AB0 is a SIMATIC ET 200iSP electronic module for intrinsically safe digital-output applications. It provides the 23.1 V DC/20 mA L-shutdown execution for hazardous-area actuator circuits and combines field diagnostics with certified Ex entity limits.

At a Glance

Brand Siemens
Model 6ES7132-7GD00-0AB0
Product Type Intrinsically Safe Digital Output Electronic Module
Core Function Controls four Ex(i) actuator circuits with L-shutdown
Application or Compatible Series SIMATIC ET 200iSP distributed I/O

Exact Output Variant

Match the 23.1 V DC/20 mA L-shutdown execution because adjacent RD and GD variants use different shutdown logic or electrical ratings.

Intrinsic-Safety Calculation

Validate the actuator and cable circuit against the stated Uo, Io, Po, Co and Lo entity limits before installation.

Station Integration

Use the correct ET 200iSP terminal arrangement, station address allocation and diagnostic parameterization.

Product Overview

Siemens 6ES7132-7GD00-0AB0 is a SIMATIC ET 200iSP electronic module for intrinsically safe digital-output applications. It provides the 23.1 V DC/20 mA L-shutdown execution for hazardous-area actuator circuits and combines field diagnostics with certified Ex entity limits.

Drives Ex(i) field circuits through transistor outputs with a separate intrinsically safe L-shutdown input. Detects wire break and short circuit and reports diagnostic alarms, red group-error status and green output status. Separates the output circuits from the backplane bus and load voltage while retaining the certified Ex interface limits.

Ordering focus: Confirm the complete article number, L-shutdown requirement, ET 200iSP terminal arrangement and every intrinsically safe loop calculation before replacing an adjacent 7RD or 7GD variant..

Key Functions

Intrinsically Safe Actuator Switching

Drives Ex(i) field circuits through transistor outputs with a separate intrinsically safe L-shutdown input.

Channel and Group Diagnostics

Detects wire break and short circuit and reports diagnostic alarms, red group-error status and green output status.

Hazardous-Area Electrical Separation

Separates the output circuits from the backplane bus and load voltage while retaining the certified Ex interface limits.

Official Specifications

Hardware and Firmware Release HW functional status 7; firmware V3.0.0
Typical Current Consumption 290 mA
Maximum Power-Bus Current 340 mA with actuator supply
Typical Power Loss 2.5 W
Maximum Address Space 2 bytes per module
Output Switching Element Transistor
No-Load Voltage Uao 23.1 V DC
Internal Resistance Ri 275 Ω
Operating Point E 17.6 V DC at 20 mA
Output Delay 2 ms maximum from 0 to 1; 1.5 ms maximum from 1 to 0
Maximum Switching Frequency 100 Hz with resistive load; 2 Hz with inductive load
Field Cable Length 500 m maximum, shielded or unshielded
Wire-Break Diagnostic Threshold R > 10 kΩ and I < 100 µA
Short-Circuit Diagnostic Threshold R < 80 Ω for one output; R < 40 Ω for paralleled outputs
Ex Output Entity Limits for IIC Uo 25.6 V; Io 96 mA; Po 0.61 W
Permissible External Entity Values for IIC Co 98 nF; Lo 3 mH
Output-Circuit Isolation No isolation channel-to-channel; isolated from the backplane bus and load voltage L+
Degree of Protection IP30
Dimensions 30 × 129 × 136.5 mm (W × H × D)
Approximate Weight 255 g

Frequently Asked Questions

Can 6ES7132-7GD00-0AB0 switch intrinsically safe actuators directly?

The module provides four transistor outputs for 23.1 V DC/20 mA Ex(i) circuits plus a separate intrinsically safe L-shutdown input.

Which terminal arrangement should I use with 6ES7132-7GD00-0AB0?

Use the ET 200iSP terminal module selected for the station’s screw- or spring-terminal scheme and approved hazardous-area configuration.

How should I calculate cable energy limits for 6ES7132-7GD00-0AB0?

For gas group IIC, keep the connected circuit within Uo 25.6 V, Io 96 mA, Po 0.61 W, Co 98 nF and Lo 3 mH.

What faults can 6ES7132-7GD00-0AB0 diagnose during commissioning?

The module can report wire break and short circuit through a parameterizable diagnostic alarm, a red group-error LED and green output-status LEDs.

What switching rates can I use with 6ES7132-7GD00-0AB0?

Keep switching at or below 100 Hz for resistive loads and 2 Hz for inductive loads.

Can I parallel outputs on 6ES7132-7GD00-0AB0 to increase current?

Do not parallel outputs for uprating because Siemens excludes this arrangement for explosion-protection reasons.

What enclosure check is required for 6ES7132-7GD00-0AB0 in a dust area?

The IP30 module must be installed in the corresponding approved enclosure for ATEX Zone 21 dust applications.

Compatibility & Ordering Notes

Before ordering 6ES7132-7GD00-0AB0: Confirm the complete article number, L-shutdown requirement, ET 200iSP terminal arrangement and every intrinsically safe loop calculation before replacing an adjacent 7RD or 7GD variant..

Compatibility Checklist

  • Confirm that the exact article suffix and L-shutdown execution match the installed project.
  • Match the ET 200iSP station, interface module and selected terminal module.
  • Keep actuator and cable entity parameters within the Uo, Io, Po, Co and Lo limits.
  • Match the L-shutdown circuit logic and wiring to the plant safety design.
  • Reserve the two-byte address allocation and configure the required diagnostic parameters.
  • Verify the zone, gas or dust group, certificates and enclosure against the site approval basis.
  • Keep field wiring within the 500 m limit and account for the diagnostic thresholds.
Hot Selling Models
VS-M12MSD-RJ45-931/3.0
XB4 BVB1
IVE4020BCPKG
5SX2 5SX23
10-UKH
3RH2122-1BB40 3RT2916-1CB00
TKHM-W-10/4
LR2K0307
DILM17-10 A-XHI22
3RT1016-1BB42 3RT1916-1LM00
3RT1016-1BB42
RB50 10K 5216
ALT-SS450
5SU1354-6KK06
PXL-C4/1 236051

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.