  • Conspectus
  • Hot Selling Models
  • Producta commendata
Conspectus

SIEMENS · SIMATIC ET 200iSP

6ES7132-7GD00-0AB0 4 DO 23.1 V DC/20 mA L-Shutdown Electronic Module

Siemens 6ES7132-7GD00-0AB0 is a SIMATIC ET 200iSP electronic module for intrinsically safe digital-output applications. It provides the 23.1 V DC/20 mA L-shutdown execution for hazardous-area actuator circuits and combines field diagnostics with certified Ex entity limits.

Ad Primum Aspectum

Nota Siemens
Modellum 6ES7132-7GD00-0AB0
Typus Producti Intrinsically Safe Digital Output Electronic Module
Functio principalis Controls four Ex(i) actuator circuits with L-shutdown
Applicatio vel series compatibiles SIMATIC ET 200iSP distributed I/O

Exact Output Variant

Match the 23.1 V DC/20 mA L-shutdown execution because adjacent RD and GD variants use different shutdown logic or electrical ratings.

Calculatio de Securitate Intrinsic

Valida circuitum actuaturis et cavi contra limites entitatis Uo, Io, Po, Co et Lo ante installationem.

Station integration

Ute arrangementem terminalis ET 200iSP correctam, allocationem adressionis stationis et parametrizationem diagnosticam.

Product Overview

Siemens 6ES7132-7GD00-0AB0 is a SIMATIC ET 200iSP electronic module for intrinsically safe digital-output applications. It provides the 23.1 V DC/20 mA L-shutdown execution for hazardous-area actuator circuits and combines field diagnostics with certified Ex entity limits.

Agit circuitus Ex(i) campi per outputes transistorum cum input L-shutdown securi intrinsic separate. Detectat interruptionem fili et circuitum curtum et notificat alarmas diagnosticas, statum rubrum erroris gruppi et statum viridis outputis. Separat circuitus outputis ab omnibus planis dorsalis et a voltatione oneris dum limites certificati interface Ex retinentur.

Focus ordinandi: Confirma numerum articuli completum, requisitum L-shutdown, arrangementem terminalis ET 200iSP et omnem calculationem loopis securis intrinsic ante substitutionem variantis 7RD vel 7GD adjacentis.

Key Functions

Commutatio Actuatoris Securi Intrinsic

Agit circuitus Ex(i) campi per outputes transistorum cum input L-shutdown securi intrinsic separate.

Diagnostics Canalium et Grupporum

Detegit interruptio fili et circuitum curtum et nuntiat alarmas diagnosticas, statum rubrum erroris gruppi et statum viridem output.

Separatio Electrica in Area Periculosa

Separat circuitus output ab omnibus bus dorsalis et a voltatione oneris, dum manent limites certificati interfacii Ex.

Official Specifications

Emissio Hardware et Firmware Status functionalis HW 7; firmware V3.0.0
Consumptio Electrica Typica 290 mA
Maxima Currus Bus Potestatis 340 mA cum supply actuatoris
Perditio potentiæ typica 2.5 W
Maxima Spatium Adressarum 2 bytes per modulo
Elementum Switching Output Transistor
Voltatio sine Onere Uao 23.1 V DC
Resistentia Interna Ri 275 Ω
Punctus Operationis E 17.6 V DC ad 20 mA
Morae Ēgressūs 2 ms maximum ab 0 ad 1; 1.5 ms maximum ab 1 ad 0
Frequentia Maxima Commutandi 100 Hz cum onere resistivo; 2 Hz cum onere inductivo
Longitudo Cavi Campi 500 m maximum, scutatum aut non scutatum
Limis Diagnosticus Rupturae Filii R > 10 kΩ et I < 100 µA
Limis Diagnosticus Curti Circuitus R < 80 Ω pro unum outputum; R < 40 Ω pro outputis parallelis
Ex Limites Entitatis Output pro IIC Uo 25.6 V; Io 96 mA; Po 0.61 W
Valores Externi Permissi pro IIC Co 98 nF; Lo 3 mH
Isolatio Circuitus Output Nulla isolatio inter canales; isolatum a bus dorsali et a tensione oneris L+
Gradus praesidium IP30
Dimensiones 30 × 129 × 136.5 mm (latus × altitudo × profunditas)
Pondus Approximatum 255 g

Quaestiones Frequenter Rogatae

Num 6ES7132-7GD00-0AB0 potest actuatores intrinsece securas directe commutare?

Modulus praebet quattuor transistorum outputus pro circuitibus Ex(i) 23.1 V DC/20 mA, plus separatam intrinsece securam L-shutdown inputum.

Quam dispositionem terminalium uti debeo cum 6ES7132-7GD00-0AB0?

Utere ET 200iSP terminalis modulo, qui ad stationis schemata vitarum aut mollarum terminalium est electus et ad periculosas zonas approbatus.

Quomodo limites energiae cableorum pro 6ES7132-7GD00-0AB0 calculare debeo?

Pro gas group IIC, serva circuitum connectum intra Uo 25.6 V, Io 96 mA, Po 0.61 W, Co 98 nF et Lo 3 mH.

Quae defectus 6ES7132-7GD00-0AB0 in tempore commissionis diagnosticare potest?

Modulus interrupturam fili et curtum circuitum per parametrabilem diagnosticam alarmam, rubram LED gruppi-erroris et virides LED status-outputiis indicare potest.

Quas velocitates commutandi cum 6ES7132-7GD00-0AB0 uti possum?

Serva commutationem ad vel infra 100 Hz pro oneribus resistivis et ad vel infra 2 Hz pro oneribus inductivis.

Possumne outputs in parallelum ponere in 6ES7132-7GD00-0AB0 ut currentem augere possim?

Non parallelizare le uscite per potenziamento perché Siemens esclude tale configurazione per motivi di protezione contro le esplosioni.

Quale verifica dell'involucro è richiesta per il modulo 6ES7132-7GD00-0AB0 in un'area polverosa?

Il modulo IP30 deve essere installato nell'involucro approvato corrispondente per applicazioni con polvere nella zona ATEX 21.

Compatibility & Ordering Notes

Prima di ordinare il modulo 6ES7132-7GD00-0AB0: Confirma numerum articuli completum, requisitum L-shutdown, arrangementem terminalis ET 200iSP et omnem calculationem loopis securis intrinsic ante substitutionem variantis 7RD vel 7GD adjacentis.

Index Compatibilitatis

  • Confermare che il suffisso esatto dell'articolo e l'esecuzione dello spegnimento L corrispondano al progetto installato.
  • Far coincidere la stazione ET 200iSP, il modulo interfaccia e il modulo terminale selezionato.
  • Mantenere i parametri dell'attuatore e del cavo entro i limiti di Uo, Io, Po, Co e Lo.
  • Far coincidere la logica e il cablaggio del circuito di spegnimento L con la progettazione della sicurezza dell'impianto.
  • Riservare l'allocazione dell'indirizzo a due byte e configurare i parametri diagnostici richiesti.
  • Verificare la zona, il gruppo di gas o polvere, i certificati e l'involucro sulla base dell'approvazione del sito.
  • Keep field wiring within the 500 m limit and account for the diagnostic thresholds.
Hot Selling Models
VS-M12MSD-RJ45-931/3.0
XB4 BVB1
IVE4020BCPKG
5SX2 5SX23
10-UKH
3RH2122-1BB40 3RT2916-1CB00
TKHM-W-10/4
LR2K0307
DILM17-10 A-XHI22
3RT1016-1BB42 3RT1916-1LM00
3RT1016-1BB42
RB50 10K 5216
ALT-SS450
5SU1354-6KK06
PXL-C4/1 236051

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000
epistula electronica ad Summum ire

Evolo Automation non est distributor autorizatus nisi aliter specificatum, nec representans, nec affinis fabricantis huius producti. Omnia signa propria et documenta sunt proprietatis suorum dominorum respective et data sunt ad identificationem et informationem.