Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens simatic 6es7526 2bf00 0ab0 f dq 8x24vdc 2a ppm safety module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIMATIC 6ES7526-2BF00-0AB0 F-DQ 8x24VDC/2A PPM Safety Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview

Siemens · SIMATIC S7-1500 / ET 200MP

6ES7526-2BF00-0AB0 F-DQ 8x24VDC/2A PPM Fail-Safe Digital Output Module

Siemens 6ES7526-2BF00-0AB0 is the SIMATIC F-DQ 8x24VDC/2A PPM fail-safe digital output module for S7-1500 and ET 200MP systems. It provides eight PPM transistor outputs and supports safety applications up to PL e and SIL 3. The module is engineered with the applicable STEP 7 Safety environment and PROFIsafe parameters. Load current, switching frequency, wiring length, installation orientation, F-parameters and the safety validation record must be checked before commissioning.

At a Glance

Brand Siemens
Model 6ES7526-2BF00-0AB0
Product Type Fail-Safe Digital Output Module
Core Function Switches eight safety-related 24 V DC actuator circuits with PPM outputs
Application or Compatible Series SIMATIC S7-1500 F-CPU central racks and ET 200MP distributed I/O

Safety Architecture

Use only with an approved F-CPU and validated PROFIsafe project that meets the required PL or SIL target.

Load and Wiring

Match every actuator to the PPM output principle, permitted current, cable length and switching-frequency limits.

Commissioning Record

Preserve the F-address, safety parameters, signature, proof-test plan and acceptance documentation.

Product Overview

Siemens 6ES7526-2BF00-0AB0 is the SIMATIC F-DQ 8x24VDC/2A PPM fail-safe digital output module for S7-1500 and ET 200MP systems. It provides eight PPM transistor outputs and supports safety applications up to PL e and SIL 3. The module is engineered with the applicable STEP 7 Safety environment and PROFIsafe parameters. Load current, switching frequency, wiring length, installation orientation, F-parameters and the safety validation record must be checked before commissioning.

Eight 24 V DC PPM transistor channels switch safety-related actuators with channel diagnostics. The module is rated for applications up to Performance Level e and Safety Integrity Level 3. It can operate centrally with an S7-1500 F-CPU or in an ET 200MP station controlled by an S7 F-CPU.

Ordering focus: confirm the complete BF00 article number, compatible F-CPU or ET 200MP station, TIA Portal Safety environment, PROFIsafe address and parameters, actuator current and PPM wiring, cable length, mounting orientation and validated PL e or SIL 3 safety function before ordering.

Key Functions

Eight Fail-Safe Outputs

Eight 24 V DC PPM transistor channels switch safety-related actuators with channel diagnostics.

High Safety Capability

The module is rated for applications up to Performance Level e and Safety Integrity Level 3.

Central or Distributed Use

It can operate centrally with an S7-1500 F-CPU or in an ET 200MP station controlled by an S7 F-CPU.

Official Specifications

Engineering Baseline TIA Portal V13 SP1 with HSP 0086 or a later supported release
Supply Voltage 24 V DC; permissible range 19.2 to 28.8 V
No-Load Current 110 mA rated; 130 mA maximum
Backplane-Bus Power Consumption 0.8 W
Typical Power Loss 11 W
Process Data Address Space 6 bytes inputs and 6 bytes outputs; 5 bytes each with S7-300/400 F-CPU
Digital Output Count 8
Output Principle PPM current-source and current-sink switching
Maximum Resistive Load Current 2 A per channel
Maximum Lamp Load 10 W
Permitted Load Resistance 12 to 2,000 ohms
Maximum Switching Frequency 30 Hz resistive; 0.1 Hz inductive; 10 Hz lamp load
Maximum Module Current 16 A horizontal to 40 °C; 8 A horizontal to 60 °C or vertical to 40 °C
Maximum Field Cable Length 1,000 m shielded; 500 m unshielded
Isolation Test Voltage 707 V DC
Functional Safety Rating PL e according to ISO 13849-1; SIL 3 according to IEC 61508
Operating Temperature 0 to 60 °C horizontal; 0 to 40 °C vertical
Dimensions 35 x 147 x 129 mm
Approximate Weight 300 g
Channel Diagnostics Wire break, short circuit, missing supply voltage and group error

Frequently Asked Questions

Which controllers can operate 6ES7526-2BF00-0AB0?

Use a compatible S7 F-CPU in a central S7-1500 rack or through an ET 200MP distributed station.

What safety level can 6ES7526-2BF00-0AB0 support?

A correctly engineered and validated application can reach PL e and SIL 3.

How much current may one 6ES7526-2BF00-0AB0 output switch?

Each channel is rated for up to 2 A with a resistive load within the total module-current limit.

Which cable lengths are permitted for 6ES7526-2BF00-0AB0?

Use no more than 1,000 m of shielded cable or 500 m of unshielded cable.

Does the mounting orientation affect 6ES7526-2BF00-0AB0?

Horizontal installation permits operation to 60 °C, while vertical installation is limited to 40 °C.

Which faults can 6ES7526-2BF00-0AB0 diagnose?

Available channel and module diagnostics include wire break, short circuit, missing supply voltage and group error.

What should be retained before replacing 6ES7526-2BF00-0AB0?

Save the safety project, F-address, PROFIsafe parameters, safety signature, wiring record and validation evidence before removal.

Compatibility & Ordering Notes

Before ordering 6ES7526-2BF00-0AB0: confirm the complete BF00 article number, compatible F-CPU or ET 200MP station, TIA Portal Safety environment, PROFIsafe address and parameters, actuator current and PPM wiring, cable length, mounting orientation and validated PL e or SIL 3 safety function before ordering.

Compatibility Checklist

  • Use only with a compatible Siemens F-CPU and approved safety engineering environment.
  • Confirm whether the module is installed centrally or in an ET 200MP distributed station.
  • Restore the exact F-address, PROFIsafe parameters and verified safety-program signature.
  • Match every field load to the PPM switching principle, 24 V DC supply and 2 A channel limit.
  • Keep total module current within the orientation- and temperature-dependent limit.
  • Maintain the shielded or unshielded field-cable length limit and the approved wiring layout.
  • Repeat the required safety validation and document the result before returning the machine to service.
Hot Selling Models
MEF10464
3SB3201-0AA31
17-REL/KSR 24/21-21-LC
7A412.3 7A 4123 400/1A
350 VF ST 2856595
TM1 6A SFB P 2800841
C11 084599
7000-08041-2101000
AX81
Murr Electronics 67320
EB 2-36/UKH
XB5AD33
0822 406 016
DX3 C10
8WD4408-0AE

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.