Siemens · SIMATIC S7-1500 / ET 200MP

6ES7526-2BF00-0AB0 F-DQ 8x24VDC/2A PPM Fail-Safe Digital Output Module

Siemens 6ES7526-2BF00-0AB0 is the SIMATIC F-DQ 8x24VDC/2A PPM fail-safe digital output module for S7-1500 and ET 200MP systems. It provides eight PPM transistor outputs and supports safety applications up to PL e and SIL 3. The module is engineered with the applicable STEP 7 Safety environment and PROFIsafe parameters. Load current, switching frequency, wiring length, installation orientation, F-parameters and the safety validation record must be checked before commissioning.

Ad Primum Aspectum

Nota Siemens
Modellum 6ES7526-2BF00-0AB0
Typus Producti Modulus digitalis outputus tutus
Functio principalis Switches eight safety-related 24 V DC actuator circuits with PPM outputs
Applicatio vel series compatibiles SIMATIC S7-1500 F-CPU central racks and ET 200MP distributed I/O

Architectura Securitatis

Usare soltanto con un F-CPU approvato e un progetto PROFIsafe convalidato che soddisfi il PL o SIL richiesto.

Carico e cablaggio

Abbinare ogni attuatore al principio di uscita PPM, alla corrente ammessa, alla lunghezza del cavo e ai limiti di frequenza di commutazione.

Registro di messa in servizio

Conservare l'indirizzo F, i parametri di sicurezza, la firma, il piano di prova funzionale e la documentazione di accettazione.

Product Overview

Siemens 6ES7526-2BF00-0AB0 is the SIMATIC F-DQ 8x24VDC/2A PPM fail-safe digital output module for S7-1500 and ET 200MP systems. It provides eight PPM transistor outputs and supports safety applications up to PL e and SIL 3. The module is engineered with the applicable STEP 7 Safety environment and PROFIsafe parameters. Load current, switching frequency, wiring length, installation orientation, F-parameters and the safety validation record must be checked before commissioning.

Otto canali transistor a 24 V DC PPM commutano attuatori connessi alla sicurezza, con diagnosi per canale. Il modulo è certificato per applicazioni fino al Livello di Prestazione e e al Livello di Integrità di Sicurezza 3. Può operare centralmente con un F-CPU S7-1500 o in una stazione ET 200MP controllata da un F-CPU S7.

Focus ordinandi: confermare prima dell'ordine il numero articolo BF00 completo, l'F-CPU o la stazione ET 200MP compatibile, l'ambiente TIA Portal Safety, l'indirizzo PROFIsafe e i parametri, la corrente dell'attuatore e il cablaggio PPM, la lunghezza del cavo, l'orientamento di montaggio e la funzione di sicurezza convalidata PL e o SIL 3.

Key Functions

Otto uscite fail-safe

Octo canales transistorum PPM directa corrente 24 V commutant actores ad securitatem pertinentes cum diagnosticis canalium.

High Safety Capability

Modulus ad applicationes usque ad Nivellem Performantiae e et Nivellem Integritatis Securitatis 3 probatus est.

Usus centralis vel distributus

Potest operari centraliter cum S7-1500 F-CPU aut in statione ET 200MP a S7 F-CPU regenda.

Official Specifications

Engineering Baseline TIA Portal V13 SP1 cum HSP 0086 aut ulteriore editione supportata
Supple voltage 24 V DC; intervallo permisso 19.2 ad 28.8 V
Currus sine onere 110 mA nominale; 130 mA maximum
Consumptio energiae per dorsalem omnibus 0,8 W
Perditio potentiæ typica 11 W
Spatium Adressarum Datarum Processus 6 octeta intrantium et 6 octeta extrantium; 5 octeta utriusque cum S7-300/400 F-CPU
Digital Output Count 8
Principium Exsulationis Commutatio PPM fontis currentis et sumptus currentis
Maxima currens oneris resistivi 2 A per canalium
Maxima onus lampadis 10 W
Permitted Load Resistance 12 ad 2 000 ohmia
Frequentia Maxima Commutandi 30 Hz resistivus; 0.1 Hz inductivus; 10 Hz lampae onus
Maxima currentis modulus 16 A horizontalis ad 40 °C; 8 A horizontalis ad 60 °C aut verticalis ad 40 °C
Maxima longitudo cavi campi 1 000 m scutatus; 500 m non scutatus
Tensio Probae Isolationis 707 V DC
Rating de Securitas Functionalis PL e secundum ISO 13849-1; SIL 3 secundum IEC 61508
Temperatura operativa 0 ad 60 °C horizontaliter; 0 ad 40 °C verticaliter
Dimensiones 35 x 147 x 129 mm
Pondus Approximatum 300 g
Diagnostics Canalium Interruptio fili, circuitus brevis, absentia tensionis suppeditationis et error gruppi

Quaestiones Frequenter Rogatae

Quae controlleres 6ES7526-2BF00-0AB0 operare possunt?

Usa compatibilem S7 F-CPU in centrali S7-1500 rack aut per stationem distributam ET 200MP.

Qualem gradum securitatis 6ES7526-2BF00-0AB0 supportare potest?

Applicatio recte ingeniosa et convalidata PL e et SIL 3 attingere potest.

Quam multum currentis unus interruptor 6ES7526-2BF00-0AB0 effluere potest?

Singulae canales ad usum usque ad 2 A cum onere resistivo intra totalem limitem currentis moduli sunt certificatae.

Quae longitudines cavi permittuntur pro 6ES7526-2BF00-0AB0?

Non plus quam 1 000 m cavi scutati aut 500 m cavi non scutati uti licet.

An positio montandi 6ES7526-2BF00-0AB0 afficit?

Installatio horizontalis operationem ad 60 °C permittit, dum installatio verticalis ad 40 °C limitatur.

Quae vitia 6ES7526-2BF00-0AB0 diagnosticare potest?

Diagnostics canalis et moduli disponibiles includunt interruptionem fili, cortocircuitum, absentiam tensionis alimentariae et errorem gruppi.

Quid retinendum est antequam 6ES7526-2BF00-0AB0 substituitur?

Antequam removitur, salva projectum securitatis, F-adressam, parametres PROFIsafe, signaturam securitatis, registrum connexionis et probationem validationis.

Compatibility & Ordering Notes

Ante ordinandum 6ES7526-2BF00-0AB0: confermare prima dell'ordine il numero articolo BF00 completo, l'F-CPU o la stazione ET 200MP compatibile, l'ambiente TIA Portal Safety, l'indirizzo PROFIsafe e i parametri, la corrente dell'attuatore e il cablaggio PPM, la lunghezza del cavo, l'orientamento di montaggio e la funzione di sicurezza convalidata PL e o SIL 3.

Index Compatibilitatis

  • Utere tantum cum compatibili Siemens F-CPU et approbato ambiente ingenieriae salutis.
  • Confirma utrum modulus centraliter an in statione distributa ET 200MP installatus sit.
  • Restitue exactam F-adressam, parametres PROFIsafe et signaturam verificatam programmatum salutis.
  • Adaptare omnem onus campi ad principium commutationis PPM, suppetitio 24 V DC et limitatio canalium 2 A.
  • Serva currentem totalem moduli intra limites dependentes ab orientatione et temperatura.
  • Serva limites longitudinis cableorum campi scutatorum aut non scutatorum et schemata connexorum approbata.
  • Repete validationem salutis requisitam et documenta resultatum antequam machinam in servitium restituas.
Hot Selling Models
MEF10464
3SB3201-0AA31
17-REL/KSR 24/21-21-LC
7A412.3 7A 4123 400/1A
350 VF ST 2856595
TM1 6A SFB P 2800841
C11 084599
7000-08041-2101000
AX81
Murr Electronics 67320
EB 2-36/UKH
XB5AD33
0822 406 016
DX3 C10
8WD4408-0AE

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000
epistula electronica ad Summum ire

Evolo Automation non est distributor autorizatus nisi aliter specificatum, nec representans, nec affinis fabricantis huius producti. Omnia signa propria et documenta sunt proprietatis suorum dominorum respective et data sunt ad identificationem et informationem.