siemens 7mh4601 1aa01 siwarex u weighing module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIWAREX U 7MH4601-1AA01 Single-Channel Weighing Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview

Siemens · SIWAREX U

7MH4601-1AA01 Single-Channel Weighing Module

Siemens 7MH4601-1AA01 is the SIWAREX U single-channel weighing module for integrating one strain-gauge scale directly into SIMATIC S7-300 or through an ET 200M distributed I/O station.

At a Glance

Brand Siemens
Model 7MH4601-1AA01
Product Type Single-Channel Weighing Module
Core Function Integrates one strain-gauge scale into SIMATIC control
Application or Compatible Series SIMATIC S7-300 and ET 200M systems

Exact Channel Identification

Use the one-channel hardware for one weighing scale.

Sensor and Serial Interfaces

Plan the load-cell input together with the SIMATIC backplane, RS232 and TTY interfaces.

Integration Route

Install directly in S7-300 or distribute through ET 200M with an IM 153-1 interface module.

Product Overview

Siemens 7MH4601-1AA01 is the SIWAREX U single-channel weighing module for integrating one strain-gauge scale directly into SIMATIC S7-300 or through an ET 200M distributed I/O station.

Sixteen-bit A/D conversion supports selectable 1, 2 and 4 mV/V measuring ranges. The 10.3 V DC excitation circuit supports approved sensor wiring up to 1,000 m. SIWATOOL commissioning through RS232 is combined with battery-free EEPROM parameter storage.

Ordering focus: confirm the one-scale requirement, S7-300 or ET 200M integration, 24 V DC supply, load-cell sensitivity and bridge resistance, four- or six-wire connection, serial interfaces, hazardous-area interface and calibration backup.

Key Functions

Configurable Weight Conversion

Sixteen-bit A/D conversion supports selectable 1, 2 and 4 mV/V measuring ranges.

Long-Distance Load-Cell Connection

The 10.3 V DC excitation circuit supports approved sensor wiring up to 1,000 m.

Service and Data Retention

SIWATOOL commissioning through RS232 is combined with battery-free EEPROM parameter storage.

Official Specifications

Auxiliary Supply 24 V DC; static 20.4 to 28.8 V; dynamic 18.5 to 30.2 V
Module Current and Power Loss 220 mA maximum; 4.8 W typical
Backplane Current 100 mA typical at 5 V
Accuracy Class 0.05% at 20 °C ±10 K
Minimum Signal per Division 1.5 µV
Update Rate 20 ms; 100 ms up to release status 4
ADC Resolution 16 bit; 65,535 parts
Measuring Ranges 0 to 1, 0 to 2 and 0 to 4 mV/V
Permissible Signal Range −1.5 to 42.5 mV
Maximum Load-Cell Distance 1,000 m
Load-Cell Excitation 10.3 V DC typical; 240 mA maximum
Load Resistance without Ex-i Greater than 41 Ω and less than 4,010 Ω
RS232 Interface 9,600 baud; 15 m maximum
TTY Interface 9,600 baud; 1,000 m maximum with external supply
EEPROM Endurance 100-year retention; 100,000 write cycles
Degree of Protection IP20 in an S7 rack; IP10 as a standalone module
Operating Temperature 0 to +60 °C horizontal; 0 to +40 °C vertical
Dimensions and Weight 40 × 125 × 130 mm; approximately 325 g

Frequently Asked Questions

Can 7MH4601-1AA01 connect two weighing channels?

No, the single-channel module is intended for one scale.

Where can I install 7MH4601-1AA01 in a SIMATIC system?

Install it directly in an S7-300 station or use ET 200M for distributed integration.

Which load cells can I connect to 7MH4601-1AA01?

Use strain-gauge Wheatstone-bridge load cells with a characteristic value up to 4 mV/V and a suitable four- or six-wire connection.

How should I commission 7MH4601-1AA01 from a PC?

Connect SIWATOOL through the RS232 interface at 9,600 baud and keep the cable within 15 m.

Can 7MH4601-1AA01 drive a remote weight display?

Yes, the TTY interface can transmit to a remote display over a loop up to 1,000 m with an external supply.

What supply should I provide for 7MH4601-1AA01?

Provide a safely isolated 24 V DC supply within the specified static or dynamic tolerance range.

What should I check before replacing 7MH4601-1AA01 with the newer module?

Confirm load-cell compatibility with the successor 6 V excitation and restore saved calibration data or recalibrate the scale.

Compatibility & Ordering Notes

Before ordering 7MH4601-1AA01: confirm the one-scale requirement, S7-300 or ET 200M integration, 24 V DC supply, load-cell sensitivity and bridge resistance, four- or six-wire connection, serial interfaces, hazardous-area interface and calibration backup.

Compatibility Checklist

  • Confirm the application requires one weighing channel for one scale.
  • Verify the S7-300 slot or ET 200M and IM 153-1 integration route.
  • Provide 24 V DC auxiliary power and the required S7 backplane supply.
  • Check load-cell sensitivity, bridge resistance and four- or six-wire wiring.
  • For the successor 7MH4950-1AA01, verify its 6 V excitation and restore calibration or recalibrate.
Hot Selling Models
022-00-7
5SY4160-7
3LD2504-0TK53 3LD9250-3B
ADNM-25-APA-15Z1-25Z2
ER12
1608620000 ZDU6
S230T250
E20720
EC96
3NY7121
PT78740 PT570024
GV2ME04
S82K-05024
RM1E48AA25
BA9043 0044769

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.