Siemens 6XV1875-5AH10 SIMATIC NET N-Connect Antenna Cable 1 m
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Match N-Connect male ends to compatible female equipment connections.
- Use within the 0–6 GHz frequency range and include the cable loss in the RF budget.
- Keep bends at or above the single-bend or repeated-bend limit.
- Do not exceed the 80 N tensile-load limit.
- Respect the separate installation and operating temperature ranges.
- Maintain properly plugged-in connectors where IP68 protection is required.
6XV1875-5AH10 SIMATIC NET N-Connect Antenna Cable 1 m
A one-metre flexible 50 Ω coaxial cable with N-Connect male connectors at both ends, rated up to 6 GHz and IP68 when plugged in.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6XV1875-5AH10 |
| Product Type | Preassembled flexible coaxial antenna cable |
| Core Function | Connects an antenna or RCoax link to compatible radio equipment |
| Application | SCALANCE M/W industrial wireless and mobile-radio installations |
N-Connect at both ends
Two preassembled N-type male connectors form the RF connection.
Defined RF losses
Typical attenuation is 0.53 dB/m at 2.4 GHz and 0.83 dB/m at 5.2 GHz.
Flexible installation
Minimum bend radius is 32 mm for a single bend or 45 mm for repeated bends.
Product Overview
6XV1875-5AH10 provides a preassembled flexible RF connection between SIMATIC NET antennas, RCoax components and compatible SCALANCE M/W equipment.
The one-metre cable uses a copper inner conductor, polyethylene-foam dielectric and a tin-plated copper braided shield beneath an FRNC sheath, with N-Connect male connectors at both ends.
Key Functions
RF interconnection
The 50 Ω cable carries frequencies from 0 to 6000 MHz for compatible industrial wireless and mobile-radio connections.
Controlled cable routing
The flexible cable supports a single-bend radius of 32 mm or a repeated-bend radius of 45 mm, with a maximum tensile load of 80 N.
Environmental connection protection
IP68 protection applies when the connectors are plugged in, while the UV-resistant FRNC sheath supports the stated environmental range.
Official Specifications
| Cable length | 1 m |
|---|---|
| Connector arrangement | Two N-Connect male connectors |
| Frequency range | 0–6000 MHz |
| Characteristic impedance | 50 Ω |
| Typical attenuation at 2.4 GHz | 0.53 dB/m |
| Typical attenuation at 5.2 GHz | 0.83 dB/m |
| Typical attenuation at 5.85 GHz | 0.89 dB/m |
| Minimum return loss | 23 dB |
| Capacitance per unit length | 82 pF/m at 1 kHz |
| Relative propagation velocity | 82% |
| Inner conductor | Copper, 1.4 mm diameter |
| Dielectric | Polyethylene foam, 3.8 mm diameter |
| Shield | Tin-plated copper wire braid |
| Cable sheath | FRNC; pastel turquoise; halogen-free and silicone-free |
| Sheath outside diameter | 6.3 ±0.2 mm |
| Minimum bend radius | 32 mm for a single bend; 45 mm for repeated bends |
| Maximum tensile load | 80 N |
| Operating, storage and transport temperature | −40 to +80 °C |
| Installation temperature | −25 to +80 °C |
| Connector protection | IP68 when plugged in |
Frequently Asked Questions
Can 6XV1875-5AH10 connect directly to an R-SMA socket?
Both cable ends are N-Connect male, so an R-SMA socket requires a matching adapter or a different cable arrangement.
How much cable attenuation should be allowed for 6XV1875-5AH10 at 5.85 GHz?
The typical attenuation is 0.89 dB per metre at 5.85 GHz.
What routing radius applies when 6XV1875-5AH10 is bent repeatedly?
The minimum permissible radius for repeated bends is 45 mm.
Is the IP68 rating of 6XV1875-5AH10 valid with an unplugged connector?
The IP68 rating applies when the connector is plugged in.
Can 6XV1875-5AH10 be installed at the same minimum temperature at which it operates?
Operation is permitted down to −40 °C, but installation is specified only down to −25 °C.
How much pulling force is permitted on 6XV1875-5AH10?
The maximum specified tensile load is 80 N.
Which radio-frequency impedance must match 6XV1875-5AH10?
The cable has a nominal characteristic impedance of 50 Ω.