siemens 6sl3244 0sa00 1aa0 et 200s fc icu24 frequency converter control unit-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6SL3244-0SA00-1AA0 ET 200S FC ICU24 Frequency Converter Control Unit

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIMATIC ET 200S FC

6SL3244-0SA00-1AA0 ET 200S FC ICU24 Frequency Converter Control Unit

Standard ICU24 control unit for ET 200S FC, supporting V/f and vector control, motor temperature sensing and encoder feedback.

At a Glance

Brand Siemens
Model 6SL3244-0SA00-1AA0
Product Type Frequency converter control unit
Core Function Motor control and station communication
Application ET 200S FC with IPM25 power modules

Motor control modes

Linear, parabolic and multi-point V/f control are complemented by vector speed and torque control with or without an encoder.

Station integration

Communication to the higher-level controller passes through the ET 200S IM 151 interface.

Motor and converter monitoring

Temperature, overload, current and voltage monitoring protect the motor and converter system.

Product Overview

6SL3244-0SA00-1AA0 provides closed-loop motor control and the communication interface for an ET 200S FC frequency converter.

The ICU24 works with an IPM25 power module and the TM-ICU15 terminal module, while its service, temperature-sensor and encoder connections support commissioning and motor supervision.

Ordering focus: Select the standard ICU24 configuration, TM-ICU15 terminal module and matching IPM25 power stage for the ET 200S station.
Key Functions

Motor control modes

Linear, parabolic and multi-point V/f control are complemented by vector speed and torque control with or without an encoder.

Station integration

Communication to the higher-level controller passes through the ET 200S IM 151 interface.

Motor and converter monitoring

Temperature, overload, current and voltage monitoring protect the motor and converter system.

Official Specifications
Required terminal module TM-ICU15, 3RK1903-3EA10
Power-stage interface PM-IF connection to IPM25
Control modes Linear/parabolic/multi-point V/f; FCC; vector speed and torque control with or without encoder
Motor temperature connection PTC/KTY84 interface
Service connection RS232 diagnostic interface
Parameter medium MMC-PS slot
Setpoint resolution 0.01 Hz digital and serial
Output-frequency resolution 0.01 Hz digital and serial
Current consumption 0.4 A typical; 0.8 A maximum
Mounting ambient −10 to +60°C horizontal; −10 to +40°C vertical
Enclosure protection IP20
Status indicators SF, RY and OL
Mounting dimensions including terminal module 15 × 220 × 156 mm (W × H × D)
Approximate weight 220 g
Frequently Asked Questions

Which terminal module is needed beneath 6SL3244-0SA00-1AA0?

Use the TM-ICU15 terminal module with order number 3RK1903-3EA10.

Does 6SL3244-0SA00-1AA0 replace an ICU24F in a safety configuration?

The standard ICU24 cannot replace the fail-safe ICU24F.

How does 6SL3244-0SA00-1AA0 communicate with the higher-level controller?

Communication passes through the ET 200S IM 151 interface module.

Can 6SL3244-0SA00-1AA0 run vector speed control with an encoder?

The control unit supports vector speed and torque control with or without encoder feedback.

Which temperature sensors connect to 6SL3244-0SA00-1AA0?

The motor temperature connection supports PTC and KTY84 sensors.

What current should I include when sizing the supply group for 6SL3244-0SA00-1AA0?

Allow for a maximum control-unit current of 0.8 A and add the current of the other group components.

Do the SH and G1–G6 LEDs indicate safety functions on 6SL3244-0SA00-1AA0?

Those LED positions have no significance on the standard ICU24.

Compatibility & Ordering Notes
Before ordering 6SL3244-0SA00-1AA0: Select the standard ICU24 configuration, TM-ICU15 terminal module and matching IPM25 power stage for the ET 200S station.

Before installation

  • Use the standard ICU24 hardware configuration and matching TM-ICU15 base.
  • Select the IPM25 power rating and station power-group components separately.
  • Connect motor temperature and encoder signals according to the selected control mode.
  • Keep supply-group current and mounting-dependent ambient temperature within their limits.
Hot Selling Models
283-601
100x260-001
6ES5373-1AA21
LC1D40A
3RV2011-1FA15
CPE10-M1CH-5L-M7
3RV2011-1GA15
3RV2011-1FA25
252-PVKG 252-PVK-400V
0822084203
3RV2411-1GA20 3RV2901-2E
6FX1120-3BB00 E:D01
3RV2011-1JA25 E:03
MZM100-B1.1 101204290
3NJ6930-3DC00

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.