Siemens 6ES7972-0BB50-0XA0 SIMATIC PROFIBUS FastConnect 90° Bus Connector with PG Socket
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Reserve clearance for both bus and PG cables.
- Use the intended FastConnect cable and exclude process cable.
- Keep current demand within the device-supplied 5 V capability.
- Do not remove a required powered endpoint connector during operation.
6ES7972-0BB50-0XA0 SIMATIC PROFIBUS FastConnect 90° Bus Connector with PG Socket
A 90-degree FastConnect PROFIBUS plug with an additional PG socket, integrated termination and an outgoing-line disconnect function.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7972-0BB50-0XA0 |
| Product Type | FastConnect bus connector |
| Core Function | Bus attachment with local commissioning access |
| Application | PROFIBUS station segments |
PG access at the station
The programming socket permits a service connection beside the permanently terminated bus cable.
Four piercing contacts
FastConnect insulation-displacement contacts terminate the incoming and outgoing bus conductors.
Selectable electrical bus end
The slide switch activates termination while disconnecting the outgoing line.
Product Overview
6ES7972-0BB50-0XA0 combines FastConnect cable termination with a local PG socket for commissioning and service.
The right-angle connector supports PROFIBUS rates up to 12 Mbit/s and requires the connected station to supply the termination circuit.
Key Functions
Provide a service connection without opening cable contacts
The PG socket offers programming-device access at the installed connector.
Terminate the specified FC bus cable
Four insulation-displacement contacts connect the bus wires, with FC process cable excluded.
Maintain endpoint termination
The integrated resistor network and disconnect switch require the correct cable assignment and station-supplied voltage.
Official Specifications
| PROFIBUS transfer-rate range | 9.6 kbit/s–12 Mbit/s |
|---|---|
| Cable outlet angle | 90° |
| Device interface | Nine-pin D-sub male connector |
| Bus-cable termination | Four insulation-displacement contacts for FastConnect cable |
| Terminating-resistor control | Integrated network activated by slide switch |
| Bus disconnect behavior | Outgoing bus disconnected when termination is activated |
| Supply from connected device | 4.75–5.25 V DC |
| Maximum current consumption | 5 mA |
| Connectable cable diameter | 8 ± 0.5 mm |
| Operating ambient temperature | 0 to +60 °C |
| Storage and transport temperature | −25 to +80 °C |
| Maximum relative humidity | 75% at +25 °C |
| Protection rating | IP20 |
| Programming-device socket | Fitted |
| Excluded FastConnect cable construction | FC process cable |
Frequently Asked Questions
Can 6ES7972-0BB50-0XA0 provide a PG connection while the FastConnect bus cable stays terminated?
Yes, the additional PG socket provides a separate programming-device connection at the installed bus plug.
Which switch setting on 6ES7972-0BB50-0XA0 disconnects the outgoing bus cable?
Activating the integrated terminating resistor also disconnects the outgoing cable.
Does 6ES7972-0BB50-0XA0 require a separate external 24 V power supply?
No, the termination circuit uses 4.75–5.25 V DC supplied by the attached device.
May I use FC process cable with the piercing contacts of 6ES7972-0BB50-0XA0?
No, FC process cable is excluded from the permitted FastConnect cable constructions.
Can I remove 6ES7972-0BB50-0XA0 from an end station without affecting segment termination?
No, removing a bus connector with required active termination from a cable end disrupts the segment.
How should I plan the two cable paths around 6ES7972-0BB50-0XA0?
Allow for the 90-degree bus cable outlet and the additional programming-device lead at the PG socket.
Can 6ES7972-0BB50-0XA0 operate at a sub-zero ambient temperature?
No, the specified operating temperature range starts at 0 °C.