Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es7972 0aa01 0xa0 simatic dp rs485 profibus and mpi repeater-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7972-0AA01-0XA0 SIMATIC DP RS485 PROFIBUS and MPI Repeater

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview

SIEMENS SIMATIC DP

6ES7972-0AA01-0XA0 SIMATIC DP RS485 PROFIBUS and MPI Repeater

RS485 repeater for coupling electrically isolated PROFIBUS or MPI bus segments, with automatic baud-rate recognition, termination switches and a PG/OP connection.

At a Glance

Brand Siemens
Model 6ES7972-0AA01-0XA0
Product Type RS485 bus repeater
Core Function Amplification and isolation of bus segments
Application PROFIBUS and MPI networks

Segment coupling

Amplify data signals between two isolated bus segments.

Automatic baud rate

Recognize the supported rates from 9.6 kbit/s to 12 Mbit/s.

Commissioning access

Use the PG/OP socket and segment-isolation switch during service work.

Product Overview

6ES7972-0AA01-0XA0 amplifies RS485 data signals and couples PROFIBUS or MPI bus segments where additional nodes, greater cable distances or ungrounded segment operation are required.

The two bus segments are electrically isolated, while the PG/OP socket is connected internally to segment 1 and its signals are amplified toward segment 2.

Ordering focus: Size each cable segment for its baud rate, count the repeater as a bus node and coordinate segment termination and grounding.
Key Functions

Bus extension

Repeaters allow a network to be divided into additional segments when node counts or cable distances exceed a single segment’s limits.

Electrical separation

Segments 1 and 2 are electrically isolated, allowing the appropriate grounded or ungrounded operating arrangement.

Service and termination

Separate termination switches, segment LEDs, a PG/OP socket and an isolation switch assist commissioning and troubleshooting.

Official Specifications
Automatic baud-rate recognition 9.6, 19.2, 45.45, 93.75, 187.5 and 500 kbit/s; 1.5, 3, 6 and 12 Mbit/s
Maximum connected nodes 31 bus nodes
Nominal supply and permissible range 24 V DC; 20.4–28.8 V DC
Supply current without PG/OP load 200 mA at nominal voltage
Supply current with 5 V PG/OP load 230 mA with a 5 V/90 mA load
Supply current with 24 V PG/OP load 200 mA with a 24 V/100 mA load
Electrical isolation 500 V AC; isolation between bus segments
Maximum repeaters in series 9
Segment length at 9.6–187.5 kbit/s 1000 m
Segment length at 500 kbit/s 400 m
Segment length at 1.5 Mbit/s 200 m
Segment length at 3–12 Mbit/s 100 m
PG/OP interface 9-pin sub-D socket; connected to segment 1
Degree of protection IP20
Dimensions (W × H × D) 45 × 128 × 67 mm
Frequently Asked Questions

When should I add 6ES7972-0AA01-0XA0 to a PROFIBUS network?

A repeater is used when additional bus nodes, longer cable distances or ungrounded segment operation are required.

Does 6ES7972-0AA01-0XA0 support Automatic baud rate for mobile equipment?

The repeater automatically recognizes its supported rates from 9.6 kbit/s to 12 Mbit/s.

How much cable can I use per segment at 12 Mbit/s with 6ES7972-0AA01-0XA0?

The maximum segment length at rates from 3 to 12 Mbit/s is 100 m.

How many units of 6ES7972-0AA01-0XA0 may I connect in series?

No more than nine RS485 repeaters may be connected in series.

Is the PG/OP socket of 6ES7972-0AA01-0XA0 isolated from both segments?

The socket is connected internally to segment 1 and is isolated from segment 2.

How do I configure grounded operation on 6ES7972-0AA01-0XA0?

Grounded operation requires a connection between the M and PE terminals.

Does 6ES7972-0AA01-0XA0 need its own PROFIBUS address?

The repeater must be counted as a bus node regardless of whether it is assigned an MPI or PROFIBUS address.

Compatibility & Ordering Notes
Before ordering 6ES7972-0AA01-0XA0: Match the bus speed, segment lengths, node count and grounding arrangement, and retain the complete repeater revision when ordering a replacement.

Compatibility Checklist for 6ES7972-0AA01-0XA0

  • Apply the cable-length limit for each individual segment at the selected baud rate.
  • Count repeaters in the subnet node budget and keep cascades within nine units.
  • Set termination for the actual segment endpoints and use the isolation switch for the intended service procedure.
  • For ungrounded operation, leave M and PE unconnected and use an ungrounded supply; 6ES7972-0AA02-0XA0 is the listed successor.
Hot Selling Models
P1KL004
VMPA1-M1H-X-PI
DSN-8-80-P
ABB E 261 C 2CDE441000R0311
Allen-Bradley 889N-F4AFC-20F
LA2KT2E 023004
FL-PP-RJ45/RJ45-B
MZT6-03VPS-KRD
VW3A3618
BES 516-377-G-E5-C-S49
VUWS-L20-M52-M-G18
MCR-SL-CVS-24-5-10-NC
ABB S 202 K 1 A 2CDS252001R0217
VUWS-L25-M32C-M-G14
efector100 IGM213 IGK3008BANKG/M/US

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.