siemens 6es7322 1bl00 0aa0 simatic s7 300 sm 322 digital output module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7322-1BL00-0AA0 SIMATIC S7-300 SM 322 Digital Output Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview

SIEMENS SIMATIC S7-300

6ES7322-1BL00-0AA0 SIMATIC S7-300 SM 322 Digital Output Module

Provide 32 transistor outputs for DC solenoid valves, contactors and signal lamps, with electrically isolated groups and per-channel status indication.

At a Glance

Brand Siemens
Model 6ES7322-1BL00-0AA0
Product Type Digital output module
Core Function Switch DC field actuators
Application S7-300 automation stations

Grouped output circuits

Four groups of eight outputs separate the load circuits.

Front connector wiring

A 40-pin front connector carries the actuator connections.

Load-aware installation

Group-current limits depend on cabinet temperature and mounting position.

Product Overview

6ES7322-1BL00-0AA0 is an SM 322 output module for operating 24 V DC field loads from a SIMATIC S7-300 station. Its 32 channels are electrically isolated in groups of eight and provide a rated output current of 0.5 A per channel.

Electronic short-circuit protection limits output faults, while individual green LEDs show channel status; the module does not provide diagnostic interrupts or readable channel diagnostics.

Ordering focus: Size each output group for its mounting position and ambient temperature, and include the 40-pin front connector in the installation plan.
Key Functions

Drive DC switching loads

The outputs operate solenoid valves, DC contactors and signal lamps within the specified current and lamp-load limits.

Separate field potential groups

Groups of eight channels are isolated from one another and from the backplane bus for grouped load-circuit wiring.

Indicate active channels locally

A green LED per channel provides a direct view of the output state during commissioning and maintenance.

Official Specifications
Output Channel Arrangement 32 channels in 4 electrically isolated groups of 8
Rated Load Voltage 24 V DC
Rated Output Current 0.5 A per channel; permitted ON-state range 5 mA to 0.6 A
Group Current, Horizontal Mounting 4 A up to 40 °C; 3 A up to 60 °C
Group Current, Vertical Mounting 2 A up to 40 °C
Backplane Current Consumption Maximum 110 mA
No-Load Load-Supply Current Maximum 160 mA
Typical Power Dissipation 6.6 W
Output ON-State Voltage At least L+ minus 0.8 V
OFF-State Residual Current Maximum 0.5 mA
Output Switching Delay Maximum 100 µs OFF to ON; maximum 500 µs ON to OFF for resistive loads
Permitted Load Resistance 48 Ω to 4 kΩ
Lamp Load Maximum 5 W per output
Maximum Switching Frequencies 100 Hz resistive; 0.5 Hz inductive DC13; 10 Hz lamp loads
Electronic Short-Circuit Protection Typical response threshold 1 A
Isolation Test Voltage 500 V DC
Actuator Connection 40-pin front connector
Module Dimensions 40 × 125 × 120 mm (W × H × D)
Frequently Asked Questions

How many solenoid-valve outputs does 6ES7322-1BL00-0AA0 provide?

The module provides 32 outputs rated at 24 V DC and 0.5 A per channel.

Does 6ES7322-1BL00-0AA0 support Front connector wiring for mobile equipment?

Use a 40-pin front connector for the output and load-supply connections.

How should I derate 6ES7322-1BL00-0AA0 in a horizontally mounted rack at 60 °C?

Limit the total output current of each group to 3 A at 60 °C.

Can I parallel outputs of 6ES7322-1BL00-0AA0 to obtain a higher current?

No, parallel outputs are allowed only for redundant load control within the same group and cannot be used to increase output capacity.

Will 6ES7322-1BL00-0AA0 send a diagnostic interrupt for a channel fault?

No, the module provides channel-status LEDs but has no diagnostic interrupt or readable diagnostic function.

What lamp load can I connect to an output of 6ES7322-1BL00-0AA0?

Each output can switch a lamp load of up to 5 W.

What should I consider when switching the 24 V supply to 6ES7322-1BL00-0AA0 with a mechanical contact?

The circuit design can produce an ON signal of approximately 50 µs at the outputs when the load supply is switched on.

Compatibility & Ordering Notes
Before ordering 6ES7322-1BL00-0AA0: Choose the connector and load wiring for the four potential groups, then check the per-channel loads and temperature-dependent group current before ordering.

Compatibility Checklist for 6ES7322-1BL00-0AA0

  • Configure the correct module and output addresses in the STEP 7 project.
  • Keep redundant parallel outputs within the same output group.
  • Account for the short switch-on pulse where connected equipment detects fast signals.
  • Use channel LEDs for local status checks and do not expect module diagnostic interrupts.
Hot Selling Models
NJ2F1N
3RH1140-2BB40 3RH1911-2GA04 3RT1916-1EH100
IG5620 IGA2005-FRKG
LV51MP
ABB DSQC 228 2668 165-12/4
41.52.9.024.0010
SAC-6P-M 8MS-M 8FS SH/../.. 1552010
K7004
46B4403S1250108882
LT208052
6NH1804-0AA01-3BB2
Elektronik 23050
I1CH002
DCCQ08M03POLK
750-431

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.