Siemens 6ES7155-6AU00-0DN0 ET 200SP IM 155-6 PN HS Interface Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Keep the server module fitted at the end of the ET 200SP station.
- Choose a supported BusAdapter with the required copper or fiber media.
- Use STEP 7 V14 or STEP 7 V5.5 SP4 or later for integration.
- Check the 24 V DC supply and the temperature limit for the mounting orientation.
SIMATIC ET 200SP
6ES7155-6AU00-0DN0 ET 200SP IM 155-6 PN HS Interface Module
High-speed PROFINET interface module with server module for ET 200SP distributed I/O.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7155-6AU00-0DN0 |
| Product Type | PROFINET interface module |
| Core Function | Connects ET 200SP I/O to a PROFINET IO controller |
| Compatible Series | SIMATIC ET 200SP |
Station size
Up to 30 modules and 125 submodules per station.
PROFINET connection
One interface with a two-port switch via a suitable BusAdapter.
High-speed operation
Isochronous bus cycle as short as 125 µs.
Product Overview
6ES7155-6AU00-0DN0 is the IM 155-6 PN HS high-speed PROFINET interface module for SIMATIC ET 200SP distributed I/O. The order item includes a server module and connects the station to a PROFINET IO controller.
The module supports up to 30 modules per rack, high-speed isochronous operation, shared-device configurations, and network diagnostics.
Key Functions
High-speed I/O update
Isochronous operation supports a minimum 125 µs bus cycle and IRT cycle choices from 125 µs to 4 ms.
Flexible network topology
The integrated two-port switch works with selectable copper or fiber BusAdapters and can act as an MRP or MRPD client.
Station diagnostics
RUN, ERROR, MAINT and power LEDs, together with channel diagnostics, help identify operating and fault states.
Official Specifications
| Firmware version | V4.0 |
|---|---|
| Rated supply voltage | 24 V DC |
| Permitted supply range | 19.2–28.8 V DC |
| Power interruption buffering | 5 ms |
| Maximum input current | 700 mA |
| Maximum inrush current | 3.7 A |
| Typical power loss | 2.4 W |
| Maximum address space per module | 32 bytes each for inputs and outputs |
| Maximum address space per station | 968 bytes each for inputs and outputs |
| Maximum modules per rack | 30 |
| Maximum submodules per station | 125 |
| PROFINET interface | One interface with two switched ports |
| PROFINET transmission | 100 Mbit/s full duplex, 100BASE-TX |
| Shortest isochronous bus cycle | 125 µs |
| Longest isochronous bus cycle | 4 ms |
| Maximum jitter | 0.25 µs |
| Horizontal installation temperature | 0–60 °C |
| Vertical installation temperature | 0–50 °C |
| Dimensions | 50 × 117 × 74 mm |
| Module weight without BusAdapter | Approximately 147 g |
Frequently Asked Questions
How many I/O modules can I attach to 6ES7155-6AU00-0DN0?
An ET 200SP station with this interface module supports up to 30 modules.
Which BusAdapter should I use with 6ES7155-6AU00-0DN0?
Choose a supported RJ45, FastConnect, SCRJ or LC BusAdapter to match the network cable.
Can 6ES7155-6AU00-0DN0 run a 125 µs isochronous cycle?
Yes, its shortest specified bus cycle is 125 µs.
Can multiple controllers share 6ES7155-6AU00-0DN0?
Yes, shared-device operation allows a maximum of four IO controllers.
What happens if I remove the server module from 6ES7155-6AU00-0DN0?
Removing it causes an invalid station configuration and stops the ET 200SP station.
Which STEP 7 version can configure 6ES7155-6AU00-0DN0?
The module can be integrated from STEP 7 V14 in TIA Portal or STEP 7 V5.5 SP4.
How can I diagnose a fault on 6ES7155-6AU00-0DN0?
Use the RUN, ERROR, MAINT and power LEDs together with the available channel diagnostics.