Siemens 6ES7155-6AU00-0DN0 ET 200SP IM 155-6 PN HS Interfasciculus Module
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Modulum serveris in extremo stationis ET 200SP manere debet.
- BusAdapter suum, qui cuprum vel fibras opticas requirit, eligere.
- STEP 7 V14 aut STEP 7 V5.5 SP4 aut posterius pro integratione utere.
- Supplimentum 24 V DC et limitem temperaturae pro positione montandi inspicere.
SIMATIC ET 200SP
6ES7155-6AU00-0DN0 ET 200SP IM 155-6 PN HS Interfacium Modulus
Modulus interfacii PROFINET altissimi celeritatis cum modulo servitoris pro distributis I/O ET 200SP.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7155-6AU00-0DN0 |
| Typus Producti | Modus Interfacialis PROFINET |
| Functio principalis | Connectit I/O ET 200SP ad PROFINET IO controllerem |
| Series Compatible | SIMATIC ET 200SP |
Magnitudo stationis
Usque ad 30 modulos et 125 submodulos per stationem.
Conexión PROFINET
Unus interfacius cum commutatore biiugato per aptum BusAdapter.
Princeps Volo Operatio
Isochronus cyclus bus usque ad 125 µs brevis.
Product Overview
6ES7155-6AU00-0DN0 est IM 155-6 PN HS alti velocitatis PROFINET interfacius modulus pro SIMATIC ET 200SP distributis I/O. Articulus ordinis includit modulum servitorem et stationem ad PROFINET IO controller connectit.
Modulus sustinet usque ad 30 modulos per scapham, operationem isochronam alti velocitatis, configurationes dispositivorum communium, et diagnosticam rete.
Key Functions
Altus velocitatis I/O renovatio
Operatio isochrona sustinet minimum cyclus bus 125 µs et optiones cycli IRT ab 125 µs ad 4 ms.
Topologia Rete Flexibilis
Commutator biiugatus integratus operat cum BusAdapter selectis cupreis aut fibrosis et potest agere ut cliens MRP vel MRPD.
Diagnostics Stationis
LED RUN, ERROR, MAINT et potentiae, una cum diagnosticis canalium, adiuvent ad statum operationis et defectus identificandum.
Official Specifications
| Versio Firmamentalis | V4.0 |
|---|---|
| Tensio nominalis supplicii | 24 V DC |
| Permissum Supplicationis Intervallum | 19,2–28,8 V CC |
| Interruptio potentiae cum tamponatione | 5 ms |
| Maximus Correntis Ingressus | 700 mA |
| Maxima Currus Inrumpens | 3.7 A |
| Perditio potentiæ typica | 2,4 W |
| Maxima spatium adressarum per modulum | 32 octetta pro singulis intratis et extratis |
| Espace d’adressage maximal par station | 968 octetta pro singulis intratis et extratis |
| Maximum modulorum per arcam | 30 |
| Maxima submodulorum numerus per stationem | 125 |
| Interficies PROFINET | Unus interfacies cum duobus portibus commutatis |
| Transmissio PROFINET | 100 Mbit/s duplex plenus, 100BASE-TX |
| Brevissimus isochronus cyclus bus | 125 µs |
| Longissimus isochronus cyclus bus | 4 ms |
| Maximum jitter | 0.25 µs |
| Horizontal installation temperature | 0–60 °C |
| Vertical installation temperature | 0–50 °C |
| Dimensiones | 50 × 117 × 74 mm |
| Module weight without BusAdapter | Approximately 147 g |
Quaestiones Frequenter Rogatae
How many I/O modules can I attach to 6ES7155-6AU00-0DN0?
An ET 200SP station with this interface module supports up to 30 modules.
Which BusAdapter should I use with 6ES7155-6AU00-0DN0?
Elige un adaptador de bus compatible RJ45, FastConnect, SCRJ o LC para que coincida con el cable de red.
¿Puede el 6ES7155-6AU00-0DN0 ejecutar un ciclo isócrono de 125 µs?
Sí, su ciclo de bus más corto especificado es de 125 µs.
¿Pueden varios controladores compartir el 6ES7155-6AU00-0DN0?
Sí, la operación de dispositivo compartido permite un máximo de cuatro controladores de E/S.
¿Qué ocurre si retiro el módulo servidor del 6ES7155-6AU00-0DN0?
Su retirada provoca una configuración de estación no válida y detiene la estación ET 200SP.
¿Qué versión de STEP 7 puede configurar el 6ES7155-6AU00-0DN0?
El módulo se puede integrar desde STEP 7 V14 en TIA Portal o desde STEP 7 V5.5 SP4.
¿Cómo puedo diagnosticar una falla en el 6ES7155-6AU00-0DN0?
Utege RUN, ERROR, MAINT et LED de potencia cum diagnosticis canalium disponibilibus.