Siemens 6ES7151-1BA00-0AB0 ET 200S IM151-1 High Feature PROFIBUS Interface
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Keep the station within 63 modules and the independent 244-byte address limits.
- Use a nine-pin Sub-D PROFIBUS connection.
- Select at least 1.5 Mbit/s when using isochronous mode.
- Fit the supplied station terminating module and configure alarms and diagnostics as required.
6ES7151-1BA00-0AB0 ET 200S IM151-1 High Feature PROFIBUS Interface
IM151-1 High Feature connects an ET 200S station to PROFIBUS DP, supporting up to 63 modules, 244 bytes each of input and output data and isochronous operation.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7151-1BA00-0AB0 |
| Product Type | Station interface module |
| Core Function | PROFIBUS coupling of distributed I/O |
| Application | ET 200S modular stations |
High Feature station
The interface supports up to 63 connected ET 200S modules.
Large process-data area
244 input bytes and 244 output bytes are available.
Isochronous operation
Isochronous mode is supported from a PROFIBUS rate of 1.5 Mbit/s.
Product Overview
6ES7151-1BA00-0AB0 is the IM151-1 High Feature interface for modular ET 200S stations on PROFIBUS DP. A nine-pin Sub-D socket connects the station to the bus at rates up to 12 Mbit/s.
The interface supports SYNC, FREEZE and direct slave-to-slave data exchange, together with alarms and diagnostics, and includes the station terminating module.
Key Functions
Extended station capacity
The interface accommodates up to 63 modules and provides independent 244-byte input and output address areas.
Coordinated PROFIBUS operation
Isochronous operation from 1.5 Mbit/s, SYNC, FREEZE and direct data exchange support coordinated station operation.
Station fault indication
BF, SF and ON LEDs provide bus-fault, group-fault and supply indications, while alarm and diagnostic functions communicate station conditions.
Official Specifications
| Maximum station expansion | 63 connected modules |
|---|---|
| Station process-data capacity | 244 input bytes and 244 output bytes |
| Maximum transmission rate | 12 Mbit/s |
| Supported PROFIBUS rates | 9.6, 19.2, 45.45, 93.75, 187.5 and 500 kbit/s; 1.5, 3, 6 and 12 Mbit/s |
| Bus connection | 9-pin Sub-D socket, RS485 |
| Isochronous-mode minimum bus rate | 1.5 Mbit/s |
| Supply interruption buffering | 20 ms |
| Maximum 1L+ current | 200 mA |
| Typical power loss | 3.3 W |
| Maximum interface output current | 80 mA |
| Status indicators | Red BF, red SF and green ON |
| Isolation test voltage | 500 V DC |
| Dimensions (W × H × D) | 45 × 119.5 × 75 mm |
| Approximate weight | 150 g |
Frequently Asked Questions
Can I use 6ES7151-1BA00-0AB0 on a PROFINET IO network?
The interface supports PROFIBUS DP through RS485 and does not support PROFINET IO.
Will isochronous mode work at 500 kbit/s with 6ES7151-1BA00-0AB0?
Isochronous operation requires a PROFIBUS transmission rate of at least 1.5 Mbit/s.
Does the 244-byte capacity of 6ES7151-1BA00-0AB0 have to be shared between inputs and outputs?
The station provides 244 bytes for inputs and a separate 244 bytes for outputs.
Can 6ES7151-1BA00-0AB0 exchange data directly with another PROFIBUS slave?
The interface supports direct slave-to-slave data exchange.
Is a station terminating module supplied with 6ES7151-1BA00-0AB0?
The interface is supplied with the ET 200S terminating module.
What happens during a brief supply interruption to 6ES7151-1BA00-0AB0?
The interface provides a specified mains or voltage-failure buffering time of 20 ms.
Which indications should I inspect when commissioning 6ES7151-1BA00-0AB0?
The red BF and SF LEDs indicate bus and group faults, while the green ON LED monitors the supply.