Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es7142 6bf50 0ab0 et 200eco pn 8 do 24 v dc 0 5 a-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7142-6BF50-0AB0 ET 200eco PN 8 DO 24 V DC 0.5 A

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIMATIC ET 200eco PN compact I/O

6ES7142-6BF50-0AB0 ET 200eco PN 8 DO 24 V DC 0.5 A

Eight 0.5 A digital outputs through four double-assigned M12 connections in a compact IP65/IP67 field device.

At a Glance

Brand Siemens
Model 6ES7142-6BF50-0AB0
Product Type Field-mounted output unit
Core Function Switch distributed DC actuators
Application PROFINET machine I/O

Field-level actuator wiring

Four M12 connections provide eight digital output channels with a 0.5 A rated current per output.

Integrated network switching

The 100BASE-TX PROFINET interface supports autonegotiation, autocrossing and MRP ring integration.

Load diagnostics

Readable diagnostics and diagnostic alarms identify wire breaks, short circuits and group errors.

Product Overview

6ES7142-6BF50-0AB0 places eight digital outputs directly in the machine environment through four double-assigned M12 actuator connections.

Its integrated Ethernet switch supports PROFINET IO, prioritized startup and MRP media redundancy, while diagnostics cover actuator wire breaks and short circuits.

Ordering focus: Match the four double-assigned M12 connections, 24 V supply arrangement and 0.5 A actuator-channel requirement.
Key Functions

Field-level actuator wiring

Four M12 connections provide eight digital output channels with a 0.5 A rated current per output.

Integrated network switching

The 100BASE-TX PROFINET interface supports autonegotiation, autocrossing and MRP ring integration.

Load diagnostics

Readable diagnostics and diagnostic alarms identify wire breaks, short circuits and group errors.

Official Specifications
Supply rating and range 24 V DC; 20.4–28.8 V DC
Required power-source class NEC Class 2
Digital output arrangement 8 channels in one group; 4 double-assigned M12 connections
Rated output current 0.5 A per channel
Maximum combined output current 4 A up to 60 °C in all mounting positions
Typical short-circuit threshold 0.7 A
Maximum off-state residual current 1.5 mA
Maximum lamp load 5 W
Maximum switching frequency 100 Hz resistive; 0.5 Hz inductive; 1 Hz lamp
Parallel output connection Redundant load control permitted; current increase not permitted
Maximum unshielded actuator cable 30 m
Ethernet transmission 100BASE-TX, up to 100 Mbit/s
Network services MRP, prioritized startup and IRT high flexibility
Typical power loss 3 W
Ingress protection IP65/IP67
Connection construction 4/5-pin M12 circular connectors
Channel isolation No isolation between output channels
Reverse polarity protection Provided
Dimensions 30 × 200 × 49 mm
Approximate mass 550 g
Frequently Asked Questions

Can I mount 6ES7142-6BF50-0AB0 outside a control cabinet?

Its IP65/IP67 construction is designed for field installation with appropriately completed M12 connections.

How are the eight outputs of 6ES7142-6BF50-0AB0 distributed across connectors?

Four M12 actuator connections each carry a double assignment.

Can I combine two outputs of 6ES7142-6BF50-0AB0 for a load above 0.5 A?

Parallel connection for current increase is not permitted.

Does 6ES7142-6BF50-0AB0 support a redundant connection to the same load?

Parallel outputs may be used for redundant load control.

Can 6ES7142-6BF50-0AB0 report a broken actuator wire?

Wire-break and short-circuit diagnostics are available as readable diagnostic information.

Can I include 6ES7142-6BF50-0AB0 in an MRP ring?

The integrated PROFINET switch supports MRP media redundancy.

Which power-source requirement applies to 6ES7142-6BF50-0AB0?

The device requires a 24 V DC power supply meeting NEC Class 2 requirements.

Compatibility & Ordering Notes
Before ordering 6ES7142-6BF50-0AB0: Match the four double-assigned M12 connections, 24 V supply arrangement and 0.5 A actuator-channel requirement.

Before installation

  • Use M12 actuator cables suited to the double-assigned pin configuration.
  • Keep each output at or below 0.5 A and the group total at or below 4 A.
  • Provide a NEC Class 2 supply within the permitted 20.4–28.8 V DC range.
  • Do not treat this standard output unit as a PROFIsafe device.
Hot Selling Models
D5033 ID-3050-BPKG
ecomat300 AC5224
NECA-S1G9-P9-MP3
MS6-LR-1/2-D6-AS
GTB10-P4211
ABB MS132-16 1SAM350000R1011
174820 21119
590 FA11KG1/4
2.5/2P-PE
PZ-G101CP
6ES7221-3BD30-0XB0
SAC-4P-10.0-PUR/FST
PI4111SMX25
41521-10-8 018.1504.190
700-377-0AA32

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop