Overview
SIMATIC ET 200S fail-safe I/O

6ES7138-4FB03-0AB0 ET 200S 4 F-DO 24 V DC 2 A Module

Four protected transistor outputs with a 2 A channel rating, safety capability up to SIL 3 and a 30 mm module width.

At a Glance

Brand Siemens
Model 6ES7138-4FB03-0AB0
Product Type Safety output electronics
Core Function Switch fail-safe DC loads
Application ET 200S PROFIsafe actuator circuits

Protected actuator outputs

Four short-circuit-protected transistor outputs provide a rated current of 2 A per channel.

Temperature-dependent load capacity

The maximum combined output current is 6 A at up to 40 °C in horizontal installation, reducing at higher ambient temperatures.

Fault visibility

Short-circuit and wire-break diagnostics are accompanied by a red group-fault LED and green output-status LEDs.

Product Overview

6ES7138-4FB03-0AB0 switches fail-safe 24 V DC loads through four transistor output channels in an ET 200S station.

Load selection must account for the minimum switched current, the total-current limit and ambient-temperature derating, rather than using the channel rating alone.

Ordering focus: Check actuator current, minimum load, mounting temperature and the required safety function before ordering.
Key Functions

Protected actuator outputs

Four short-circuit-protected transistor outputs provide a rated current of 2 A per channel.

Temperature-dependent load capacity

The maximum combined output current is 6 A at up to 40 °C in horizontal installation, reducing at higher ambient temperatures.

Fault visibility

Short-circuit and wire-break diagnostics are accompanied by a red group-fault LED and green output-status LEDs.

Official Specifications
Rated load supply 24 V DC
Typical supply current 100 mA from L+ without load
Maximum backplane current 28 mA at 3.3 V
Typical power loss 3.5 W
Output construction 4 short-circuit-protected transistor outputs
Rated output current 2 A per channel
Permitted signal 1 current 20 mA–2.4 A
Signal 1 output voltage At least L+ minus 2 V
Maximum off-state leakage P switch: 0.5 mA; M switch: 4 mA
Maximum lamp load 10 W
Permitted load resistance 12 Ω–1 kΩ
Switching frequency Resistive: 30 Hz; inductive: 0.1 Hz; lamp: 10 Hz
Combined output current, horizontal 6 A up to 40 °C; 5 A up to 55 °C; 4 A up to 60 °C
Combined output current, vertical 4 A up to 40 °C
Maximum actuator cable length 200 m, shielded or unshielded
Parallel output operation Not permitted for current increase or redundant load control
Safety capability Up to SIL 3, Category 4 and PL e
Isolation test voltage 500 V DC
Reverse polarity protection Not provided
Dimensions and approximate mass 30 × 81 × 52 mm; 85 g
Frequently Asked Questions

Can I use 6ES7138-4FB03-0AB0 to drive a PLC digital input?

Controlling a digital input is not supported by this output module.

Can I parallel two channels of 6ES7138-4FB03-0AB0 to increase current?

Parallel operation is not permitted for either higher current or redundant load control.

Will 6ES7138-4FB03-0AB0 work with an actuator drawing less than 20 mA?

The permitted signal 1 load current starts at 20 mA.

How much current can 6ES7138-4FB03-0AB0 switch at 60 °C in a horizontal station?

The combined output current is limited to 4 A at an ambient temperature of 60 °C.

Can I connect a 15 W lamp directly to 6ES7138-4FB03-0AB0?

The maximum permitted lamp load is 10 W.

Does an off output of 6ES7138-4FB03-0AB0 have zero leakage current?

The maximum off-state leakage is 0.5 mA for the P switch and 4 mA for the M switch.

Which ET 200S interface allows 6ES7138-4FB03-0AB0 to use PROFINET?

An IM151-3 HF interface module enables the PROFINET station connection.

Compatibility & Ordering Notes
Before ordering 6ES7138-4FB03-0AB0: Check actuator current, minimum load, mounting temperature and the required safety function before ordering.

Before installation

  • Size each actuator for the 20 mA minimum load and 2 A rated channel current.
  • Apply the total-current limits for the actual installation direction and ambient temperature.
  • Do not connect outputs in parallel or use them to control digital inputs.
  • Use the suitable PROFIsafe station interface and maintain correct 24 V DC supply polarity.
Hot Selling Models
8TX 2891929
6ES7194-4CA50-0AA0
4-2/3AN 1770360000
V53AARA1100A
ADN-32-50-IPA
29854S 08272S 15712S
ET3-0910
X4V8
6ES7132-6GD51-0BA0
1300621013 113030K20M040E
000N38027/1
Allen-Bradley 1492-SP1C050
3SF5814-0AZ
CD3000M-DRIVE
ZCKJ1121 077491

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.