Siemens 6ES7138-4DF01-0AB0 SIMATIC ET 200S 1SI Serial Interface Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Choose one serial electrical interface and match the partner wiring.
- Configure ASCII or 3964R and the same character framing at both ends.
- Use the correct IM 151 generation when allocating cyclic data transfer.
- Respect the separate RS232 and RS485 cable-length limits.
6ES7138-4DF01-0AB0 SIMATIC ET 200S 1SI Serial Interface Module
Single-channel 1SI module with RS232, RS422 or RS485 signaling, ASCII and 3964R drivers and rates up to 115.2 kbit/s.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7138-4DF01-0AB0 |
| Product Type | Serial communication module |
| Core Function | Point-to-point data exchange |
| Application | ET 200S serial-device stations |
Selectable serial signaling
One serial channel supports RS232, RS422 or RS485 field connections.
ASCII and 3964R handling
Integrated protocol drivers exchange telegrams of up to 224 bytes.
Station-dependent data transfer
Compatible newer IM 151 versions transfer 32 bytes per direction in a PLC sampling cycle.
Product Overview
6ES7138-4DF01-0AB0 connects a serial device to an ET 200S station through a configurable single-channel interface.
The 1SI supports ASCII and 3964R communication, selectable character framing and 224-byte telegrams, while the station interface determines the number of bytes exchanged per PLC sampling cycle.
Key Functions
Selectable serial signaling
One serial channel supports RS232, RS422 or RS485 field connections.
ASCII and 3964R handling
Integrated protocol drivers exchange telegrams of up to 224 bytes.
Station-dependent data transfer
Compatible newer IM 151 versions transfer 32 bytes per direction in a PLC sampling cycle.
Official Specifications
| Serial channel | 1 configurable RS232/RS422/RS485 interface |
|---|---|
| Integrated protocol drivers | ASCII and 3964R |
| Maximum telegram length | 224 bytes for either protocol |
| Maximum transmission rate | 115.2 kbit/s |
| Character data bits | 7 or 8 |
| Parity settings | None, odd, even or any |
| Rated supply | 24 V DC with reverse-polarity protection |
| L+ supply current | 120 mA maximum |
| 3.3 V backplane current | 10 mA maximum |
| Typical power loss | 1.2 W |
| Maximum RS232 cable | 15 m |
| Maximum RS485 cable | 1200 m |
| PLC-cycle data transfer | 32 bytes sent and received with IM151-1 Standard from 1AA04 or High Feature from 1BA01; otherwise 8 bytes |
| Interface isolation | RS232 and RS422/485 isolated from the internal supply |
| Status LEDs | RxD, TxD and red SF |
| Operating temperature | 0 to +60°C |
| Dimensions and weight | 15 × 81 × 52 mm (W × H × D); approximately 50 g |
Frequently Asked Questions
Does 6ES7138-4DF01-0AB0 provide three independently usable serial channels?
The module provides one serial channel with a selectable RS232, RS422 or RS485 electrical interface.
How long a telegram can I exchange through 6ES7138-4DF01-0AB0?
Both integrated protocol drivers support telegrams up to 224 bytes.
Which station interfaces allow the 32-byte PLC-cycle transfer of 6ES7138-4DF01-0AB0?
Use IM151-1 Standard from 6ES7151-1AA04-0AB0 or High Feature from 6ES7151-1BA01-0AB0 for thirty-two bytes in each direction per sampling cycle.
What happens to the PLC-cycle transfer size of 6ES7138-4DF01-0AB0 with an older IM 151?
The transfer size is eight bytes in each direction per sampling cycle.
Can I connect a serial partner that sends seven data bits to 6ES7138-4DF01-0AB0?
The character format supports seven or eight data bits.
Can I use the 1200 m cable limit of 6ES7138-4DF01-0AB0 for RS232 wiring?
RS232 cable length is limited to fifteen meters while the 1200 m limit applies to RS485.
Which indicators should I watch when commissioning 6ES7138-4DF01-0AB0?
The RxD and TxD LEDs show serial activity and the red SF LED indicates a group fault.