siemens 6es7136 6ra00 0bf0 simatic et 200sp f rq relay output module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7136-6RA00-0BF0 SIMATIC ET 200SP F-RQ Relay Output Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIMATIC ET 200SP

6ES7136-6RA00-0BF0 SIMATIC ET 200SP F-RQ Relay Output Module

F-RQ module with one relay output containing two normally open contacts, a 24 V DC coil and a temperature-dependent five-ampere load rating.

At a Glance

Brand Siemens
Model 6ES7136-6RA00-0BF0
Product Type Safety relay output module
Core Function Relay contact expansion for fail-safe output control
Application ET 200SP safety circuits with suitable F-DQ control

Fail-safe controlled relay stage

Suitable F-DQ control allows the module to serve safety-related relay switching applications.

Two normally open contacts

One relay output provides two normally open contacts for the connected circuit arrangement.

Diagnostic integration

A status byte and local DIAG and channel indicators support station diagnostics.

Product Overview

6ES7136-6RA00-0BF0 provides a relay-output stage for ET 200SP safety circuits controlled by an appropriate fail-safe digital output.

The module has two normally open contacts in one relay output, uses a type F0 BaseUnit and requires load-current derating, external contact protection and the specified control-cable limit.

Ordering focus: Match the F0 BaseUnit, fail-safe controlling output, contact-load duty and required safety application design.
Key Functions

Fail-safe controlled relay stage

Suitable F-DQ control allows the module to serve safety-related relay switching applications.

Two normally open contacts

One relay output provides two normally open contacts for the connected circuit arrangement.

Diagnostic integration

A status byte and local DIAG and channel indicators support station diagnostics.

Official Specifications
BaseUnit and color code BU type F0; CC42
Relay output arrangement 1 output with 2 normally open contacts
Coil supply 24 V DC rated; 20.4–28.8 V DC permitted
Maximum relay coil current 70 mA
Typical power loss 1 W
Backplane power consumption 100 mW
Input address space 1 byte
Rated contact switching voltage 24 V DC / 230 V AC
Maximum thermal continuous current 5 A
Horizontal total-current limits 5 A at up to 40°C; 4 A at up to 50°C; 3 A at up to 60°C
Vertical total-current limit 3 A at up to 50°C
Minimum contact current 1 mA; 10 mA after previously exceeding 300 mA
Maximum lamp load 25 W
External contact protection Required; 6 A
Switching-frequency limits 2 Hz resistive; 0.1 Hz DC13 inductive; 2 Hz AC15 inductive
Cable-length limits Load contacts: 500 m shielded or 300 m unshielded; control input: 10 m
Achievable safety classification Up to PL e / Category 4 / SIL 3 with suitable F-DQ control and the required safety application
Operating ambient 0 to +60°C horizontal; 0 to +50°C vertical
Diagnostic indication Green/red DIAG LED and green channel-status LED
Dimensions and approximate weight 20 × 73 × 58 mm (W × H × D); 56 g
Frequently Asked Questions

Does 6ES7136-6RA00-0BF0 contain two independently controlled relay outputs?

The module provides one relay output with two normally open contacts.

Can I claim SIL 3 from 6ES7136-6RA00-0BF0 without a suitable fail-safe controlling output?

The stated achievable safety class requires control by an appropriate F-DQ within the safety application.

Which BaseUnit must I use with 6ES7136-6RA00-0BF0?

Use a type F0 BaseUnit with the CC42 module identification.

Can 6ES7136-6RA00-0BF0 carry five amperes at a horizontal ambient temperature of sixty degrees Celsius?

The horizontal total-current limit at sixty degrees Celsius is three amperes.

What external protection is specified for the contacts of 6ES7136-6RA00-0BF0?

External relay-output protection of six amperes is required.

How long may the control-input cable to 6ES7136-6RA00-0BF0 be?

The maximum control-input cable length is ten metres.

Can a previously heavily loaded contact of 6ES7136-6RA00-0BF0 later switch a one-milliampere signal?

After a contact has exceeded three hundred milliamperes, its stated minimum switching current becomes ten milliamperes.

Compatibility & Ordering Notes
Before ordering 6ES7136-6RA00-0BF0: Match the F0 BaseUnit, fail-safe controlling output, contact-load duty and required safety application design.

Before installation

  • Select the type F0 BaseUnit and an appropriate fail-safe controlling output.
  • Design and validate the complete safety circuit for the required performance level.
  • Apply contact-load, temperature derating and external protection requirements together.
  • Keep the control cable within ten metres and observe the separate load-contact cable limits.
Hot Selling Models
MR-J3ENCBL2M-A1-L
ABB S202MB6UC 2CDS272061R0065
3SE2120-7C
7700-A5A01-U1D0100
IB300006 02351-93650
N2R231H-06QE4
SV9344.020
6EP1332-2BA00
Allen-Bradley 1492-SP2C100
9494/A1-E0
EMGQL20-50
2320157
8TX 2832632
10N3003923
Allen-Bradley 25-RF7P5-AL

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.