Overview
SIEMENS SIMATIC ET 200S

6ES7132-4BF50-0AB0 ET 200S Eight-Channel Sink Output Module

Eight sinking transistor outputs with 0.5 A rated current per channel, short-circuit protection and a maximum 4 A module load.

At a Glance

Brand Siemens
Model 6ES7132-4BF50-0AB0
Product Type Digital output electronics module
Core Function Sinking control of DC loads
Application Distributed actuator stations

Eight sink channels

Transistor outputs provide 0.5 A rated current per channel.

Protected switching

Short-circuit protection has a typical 1.5 A response threshold.

One-byte allocation

The module uses a maximum of one output byte.

Product Overview

6ES7132-4BF50-0AB0 provides eight sinking transistor outputs for 24 V DC loads in an ET 200S station. Each channel has a rated output current of 0.5 A, while the module total is limited to 4 A.

The output stage includes short-circuit protection and an inductive shutdown-voltage limit. Individual green indicators show commanded output states, and the module takes its load voltage from the associated power module.

Ordering focus: Coordinate sink-output load wiring, power-module polarity and the 4 A module total before assigning the output channels.
Key Functions

Switch eight sinking loads

The eight transistor channels have a 0.5 A rated current, a 5–600 mA permissible signal-1 range and a 4 A maximum total per module.

Limit fault current

Short-circuit protection responds at a typical 1.5 A, while the typical inductive shutdown-voltage limit is 47 V.

Display channel states

Green output indicators show the state of the corresponding channel without providing a separate diagnostic function.

Official Specifications
Output channels 8 transistor sink outputs
Rated load voltage 24 V DC from the power module
Channel current 0.5 A rated; permissible signal-1 range 5–600 mA
Maximum module current 4 A
Maximum signal-0 residual current 5 µA
Short-circuit protection threshold 1.5 A typical
Inductive shutdown-voltage limit 47 V typical
Maximum lamp load 5 W
Load-resistance range 48–3,400 Ω
Maximum resistive-load delay 300 µs from 0 to 1; 600 µs from 1 to 0
Maximum switching frequency Resistive: 100 Hz; inductive: 0.5 Hz; lamp: 10 Hz
Maximum cable length 1,000 m shielded; 600 m unshielded
Maximum internal currents 5 mA from load voltage L+ without load; 10 mA from the 3.3 V backplane
Typical power loss 1.5 W
Maximum output address space 1 byte
Electrical isolation No isolation between channels; isolation from backplane bus
Insulation test voltage 500 V DC
Output indication and diagnostics Green status indicator; no diagnostic function
Dimensions and weight 15 × 81 × 52 mm (W × H × D); approximately 40 g
Frequently Asked Questions

Can I use all eight outputs of 6ES7132-4BF50-0AB0 at their 0.5 A rating?

The eight rated output currents total 4 A, which is the maximum permitted module current.

Does short-circuit protection on 6ES7132-4BF50-0AB0 also provide a diagnostic message?

The outputs have short-circuit protection but the module has no diagnostic function.

Can I join two outputs of 6ES7132-4BF50-0AB0 to obtain a higher load current?

Parallel outputs must not be used to increase the load-current rating.

What minimum load current should I plan for on 6ES7132-4BF50-0AB0?

The permissible signal-1 output-current range starts at 5 mA.

Can 6ES7132-4BF50-0AB0 switch a 10 W indicator lamp?

The maximum lamp load is 5 W.

What delays should a fast resistive load allow for on 6ES7132-4BF50-0AB0?

The maximum output delays are 300 µs for switching on and 600 µs for switching off.

How should I coordinate power-module polarity with 6ES7132-4BF50-0AB0?

Use the same correctly polarized load voltage as the power module for the specified reverse-voltage protection.

Compatibility & Ordering Notes
Before ordering 6ES7132-4BF50-0AB0: Match the sinking output circuit and the associated power-module load supply, then coordinate channel and aggregate load currents.

Compatibility Checklist for 6ES7132-4BF50-0AB0

  • Keep each channel at its 0.5 A rated duty and the total at or below 4 A.
  • Use the same correctly polarized load supply as the power module.
  • Do not parallel outputs to increase current.
  • Keep lamp loads within 5 W.
Hot Selling Models
NJ40+U1+A2 14131S 08272S 015712S
CA3-16C CA3-16-10
VAD-1/8 14015
SDBT-MS-20NL-ZN-E-5-LE-EX6
IA5127 IA-3010-BPKG/US-104-DPS
3RU1900-1C
GSE5/12
6FX1815-1CX03-8BA
3SB3500-3BG01
WN 101943
CPE14-M1BH-3GL-QS-6
CDQ2L40TF50DMZ
VFOF-LE-BAH-G14-Q8
BES00HT BES 516-3007-E2-X-05
7000-40561-0300500

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.