Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es5941 7ua12 s5 115u cpu 941-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIMATIC S5-115U 6ES5941-7UA12 CPU 941

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

Siemens · SIMATIC S5-115U

6ES5941-7UA12 CPU 941 Central Processing Unit

Siemens 6ES5941-7UA12 is the SIMATIC S5-115U CPU 941 central processing unit with internal RAM, expandable program memory, digital and analog address areas, timers and counters for legacy STEP 5 control systems.

At a Glance

Brand Siemens
Model 6ES5941-7UA12
Product Type SIMATIC S5-115U central processing unit
Core Function Executes cyclic, interrupt-driven and time-controlled STEP 5 programs
Application or Compatible Series SIMATIC S5-115U automation systems

Revision Check

Match the complete order number and operating-system release before using existing data-handling blocks.

Memory Retention

Preserve the installed memory submodule and record the configured retentive flags, timers and counters.

Project Backup

Create a complete STEP 5 backup before removing the CPU from the S5-115U rack.

Product Overview

Siemens 6ES5941-7UA12 is the SIMATIC S5-115U CPU 941 central processing unit with internal RAM, expandable program memory, digital and analog address areas, timers and counters for legacy STEP 5 control systems.

Cyclic, interrupt-driven and time-controlled scan modes support S5-115U machine sequences. Internal RAM can be combined with a memory submodule for a larger total program. Dedicated digital and analog address areas, flags, timers and counters support compact control tasks.

Ordering focus: match the complete CPU revision, STEP 5 project, operating-system release, memory submodule, retentive resource setup and S5-115U rack configuration.
Key Functions

STEP 5 Program Control

Cyclic, interrupt-driven and time-controlled scan modes support S5-115U machine sequences.

Expandable Program Storage

Internal RAM can be combined with a memory submodule for a larger total program.

Integrated Control Resources

Dedicated digital and analog address areas, flags, timers and counters support compact control tasks.

Official Specifications
Execution Time for 1000 Statements Approximately 10 ms
Internal Program RAM 2 KB
Maximum Total Program Memory 18 KB including memory submodule
Default Cycle Monitoring Time Approximately 500 ms; programmable
Maximum Digital Input Address Range 1024 inputs, I 0.0 to I 127.7
Maximum Digital Output Address Range 1024 outputs, Q 0.0 to Q 127.7
Maximum Analog Input Address Range 64 words, PW 128 to PW 254
Maximum Analog Output Address Range 64 words, PW 128 to PW 254
Available Flags 1024
Available Timers 128
Available Counters 128
Retentive Resource Selection All, half or none for flags, timers and counters
Timer Range 0.01 to 9990 s
Counter Range 0 to 999
Instruction Set Approximately 170 operations
Data-Handling Block Requirement for IP 252 Operating-system release Z10 or later
Frequently Asked Questions

What should I back up before removing 6ES5941-7UA12 from an S5-115U rack?

Back up the complete STEP 5 program, block directory and CPU parameter settings.

How much internal program memory is available in 6ES5941-7UA12?

The CPU provides two kilobytes of internal RAM for the control program.

Can 6ES5941-7UA12 retain timers and counters after a power interruption?

The project can configure all, half or none of the timer and counter resources as retentive.

Which memory detail matters when replacing 6ES5941-7UA12?

Keep the compatible memory submodule and verify that the total program does not exceed the replacement capacity.

Why must the operating-system release of 6ES5941-7UA12 be checked with an IP 252?

Data exchange with that intelligent module requires the specified CPU and data-handling block revision level.

What cycle supervision is available on 6ES5941-7UA12?

The CPU provides a programmable cycle monitor with a default value of about five hundred milliseconds.

How should the address map be compared before commissioning 6ES5941-7UA12?

Compare the digital and analog process-image ranges with every installed I/O module and the saved STEP 5 project.

Compatibility & Ordering Notes
Before ordering 6ES5941-7UA12: match the complete CPU revision, STEP 5 project, operating-system release, memory submodule, retentive resource setup and S5-115U rack configuration.

Compatibility Checklist

  • Confirm the target installation is a SIMATIC S5-115U rack configured for CPU 941.
  • Retain the original memory submodule only after checking its capacity and compatibility.
  • Compare intelligent-module function blocks and required operating-system revisions before restart.
Hot Selling Models
S41-5-DP SV2187
E20052 FT-00-PA-E3 FT00PAE3
VUVG-L10-B52-T-M5-1P3 L10B52TM51P3
9650000000B EQB96
5SY7204-7
20DIL
3RV1901-1A
ZB4BVB5 089241
3RH1911-1MA20
FAZ-B20/1 278536
3RV2925-5EB
5SX41 C16
5SX22C6
PKZM0-4-T
280-374 280374

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.