Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es5460 4ua13 s5 460 analog input module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIMATIC S5 6ES5460-4UA13 460 Analog Input Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

Siemens · SIMATIC S5-135U/155U

6ES5460-4UA13 460 Floating Eight-Channel Analog Input Module

Siemens 6ES5460-4UA13 is a SIMATIC S5-135U/155U floating eight-channel analog input module that uses plug-in measuring-range submodules for voltage, current and resistance-sensor applications.

At a Glance

Brand Siemens
Model 6ES5460-4UA13
Product Type Floating eight-channel analog input module
Core Function Acquires analog process signals through selectable measuring-range submodules
Application or Compatible Series SIMATIC S5-135U and S5-155U systems

Range Submodules

Identify every installed measuring-range submodule and reproduce its channel position.

Acquisition Settings

Record line-frequency selection, scan mode, gain, compensation and wire-break settings.

Migration Planning

Compare signal type and wiring with the approved Siemens adapter or replacement module before conversion.

Product Overview

Siemens 6ES5460-4UA13 is a SIMATIC S5-135U/155U floating eight-channel analog input module that uses plug-in measuring-range submodules for voltage, current and resistance-sensor applications.

Plug-in range submodules adapt the inputs for voltage, current, two-wire or four-wire transmitters and resistance sensors. The analog input design supports isolated process-signal acquisition in S5-135U and S5-155U racks. Line-frequency integration, single or cyclic scanning, gain and wire-break monitoring can be set for the application.

Ordering focus: confirm the full article number, S5 rack type, every measuring-range submodule, channel wiring, line frequency, scan mode, gain, compensation, wire-break monitoring and migration adapter if used.
Key Functions

Selectable Measurement Types

Plug-in range submodules adapt the inputs for voltage, current, two-wire or four-wire transmitters and resistance sensors.

Floating Channel Design

The analog input design supports isolated process-signal acquisition in S5-135U and S5-155U racks.

Configurable Conversion

Line-frequency integration, single or cyclic scanning, gain and wire-break monitoring can be set for the application.

Official Specifications
Scanning Hardware Relay multiplexer
Cycle Time for Eight Inputs at 50 Hz 0.48 s
Integration Time at 50 Hz 20 ms
Integration Time at 60 Hz 16.67 ms
Maximum Shielded Cable Length Less than 200 m
Rack Space Requirement 1 slot
Maximum Input Voltage 18 V
Selectable Scan Modes Single or cyclic scanning
Selectable Line-Frequency Rejection 50 Hz or 60 Hz
Selectable Gain Modes Normal x1 or special x4
Data Representation Two’s complement
Wire-Break Monitoring Configurable for channel groups 0 to 3 and 4 to 7
Current Measuring Range 0 to 20 mA or 4 to 20 mA with the applicable range submodule
Current Overload Range 0 to 40 mA or 4 to 40 mA
Current-Range Scaling 0 mA = 0 units; 4 mA = 512 units; 20 mA = 2,048 units
S7-1500 Voltage/Resistance Adapter 6EZ2041-8UG11-0AE0
S7-1500 Two-Wire Current Adapter 6EZ2041-8UG11-2AE0
S7-1500 Four-Wire Current Adapter 6EZ2041-8UG11-3AE0
Frequently Asked Questions

Which measuring ranges can I use with 6ES5460-4UA13?

The available voltage, current and resistance ranges depend on the plug-in measuring-range submodule fitted to each channel.

What should I record before replacing 6ES5460-4UA13?

Record every range submodule, channel wire, polarity, shield, gain, scan and monitoring setting.

Can 6ES5460-4UA13 scan all eight inputs cyclically?

Yes, the module can be set for cyclic scanning and completes an eight-input cycle in 0.48 seconds at 50 hertz.

How should I set line-frequency rejection on 6ES5460-4UA13?

Select 50 or 60 hertz to match the local mains frequency and required integration time.

What should I check if 6ES5460-4UA13 reports a broken wire?

Inspect the affected channel group, field cable, transmitter supply, terminals and the configured monitoring switch.

Can 6ES5460-4UA13 be migrated to newer Siemens I/O?

Yes, Siemens lists signal-specific adapters and S7-1500 or ET 200SP modules, but the exact range submodule and wiring must be matched.

Which data format should my program expect from 6ES5460-4UA13?

Interpret converted values in the configured two’s-complement representation and apply the selected range scaling.

Compatibility & Ordering Notes
Before ordering 6ES5460-4UA13: confirm the full article number, S5 rack type, every measuring-range submodule, channel wiring, line frequency, scan mode, gain, compensation, wire-break monitoring and migration adapter if used.

Compatibility Checklist

  • Inventory the fitted measuring-range submodule in each channel position before ordering a replacement.
  • Preserve the S5 rack slot, shield routing, transmitter supplies and acquisition switch settings.
  • For migration, select the Siemens adapter and successor I/O according to the actual voltage, current or resistance signal type.
Hot Selling Models
VS-PNRJ45-PNRJ45-93B-0.5
L7A6-AN
1957620000 PT6
OP-87775
475650
PSSuES4DID
3RT2017-1AP01 3RH2911-1HA22 3RT2916-1BD00
3RV1011-1KA10
CPV14-M1H-5JS-1/8
51540
ABB S202P-K1 2CDS282001R0217
3VA9221-0WF30
ABB CRM4LS 1SVR405651R3100
NRB4-12GS40-E2-V1
3RT1024-1BB40 3RH1921-1FA22