Siemens SIMATIC ET 200SP HA AI 16xTC/8xRTD Module 6DL1134-6JH00-0EH1
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Product Overview
- Key Functions
- Official Specifications
- Frequently Asked Questions
- Compatibility & Ordering Notes
- Hot Selling Models
- Recommended Products
Overview
Siemens · SIMATIC ET 200SP HA
6DL1134-6JH00-0EH1 SIMATIC ET 200SP HA AI 16xTC/8xRTD Module
The AI 16xTC/8xRTD 2-/3-/4-wire HA module provides temperature, resistance and voltage measurement for ET 200SP HA process stations and supports I/O redundancy.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6DL1134-6JH00-0EH1 |
| Product Type | High-availability temperature and resistance analog input module |
| Core Function | Measures thermocouple, RTD, resistance and voltage signals in process applications |
| Application or Compatible Series | ET 200SP HA stations using up to 16 thermocouples or eight RTD channels |
Exact Identification
Match 6DL1134-6JH00-0EH1 character by character and confirm the complete SIMATIC ET 200SP HA AI 16xTC/8xRTD Module designation.
Interface Arrangement
Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.
Configuration Check
Preserve the approved engineering project, network parameters and application data used by the installed system.
Product Overview
The AI 16xTC/8xRTD 2-/3-/4-wire HA module provides temperature, resistance and voltage measurement for ET 200SP HA process stations and supports I/O redundancy.
The module accepts up to sixteen thermocouple channels or eight resistance-temperature channels. Two-, three- and four-wire resistance connections are supported for installation flexibility. I/O redundancy and detailed channel diagnostics support process-control availability requirements.
Key Functions
Flexible Temperature Inputs
The module accepts up to sixteen thermocouple channels or eight resistance-temperature channels.
Multiple RTD Wiring Methods
Two-, three- and four-wire resistance connections are supported for installation flexibility.
High-Availability Integration
I/O redundancy and detailed channel diagnostics support process-control availability requirements.
Official Specifications
| Firmware Version | V1.1 |
|---|---|
| Firmware Update | Supported |
| Thermocouple Channels | Up to 16 |
| RTD or Resistance Channels | Up to 8 |
| RTD Connection Methods | 2-, 3- or 4-wire |
| Voltage Measurement | Supported |
| Terminal Block Types | H1 or M1 |
| Thermocouple or Voltage Process Time | 194 ms per channel |
| RTD or Resistance Process Time, 2-Wire | 194 ms per channel |
| RTD or Resistance Process Time, 3-Wire | 378 ms per channel |
| RTD or Resistance Process Time, 4-Wire | 198 ms per channel |
| I/O Redundancy | Supported |
| Redundant Process-Value Cycle | Twice the configured single-module cycle |
| Module Height | 115 mm |
| Module Depth | 138 mm |
Frequently Asked Questions
How many thermocouple channels can 6DL1134-6JH00-0EH1 acquire?
Up to sixteen channels can be configured for thermocouple or voltage measurement.
How many RTD channels can 6DL1134-6JH00-0EH1 use?
Up to eight channels can be configured for resistance-temperature or resistance measurement.
Which RTD wiring methods are supported by 6DL1134-6JH00-0EH1?
Two-, three- and four-wire connections are supported.
Can 6DL1134-6JH00-0EH1 be used in an I/O-redundant station?
Yes; the module supports the documented ET 200SP HA I/O redundancy arrangement.
Which terminal blocks fit 6DL1134-6JH00-0EH1?
Use the specified H1 or M1 terminal-block type for the engineered station.
Why can the process time differ between channels on 6DL1134-6JH00-0EH1?
The selected sensor type and two-, three- or four-wire measurement method determine the channel processing time.
What must be checked after replacing 6DL1134-6JH00-0EH1?
Verify sensor type, wiring method, reference junction, limits, diagnostics, redundancy pairing and channel parameters.
Compatibility & Ordering Notes
Compatibility Checklist
- Use the module only in an ET 200SP HA configuration supported by the installed interface module and engineering release.
- Match every thermocouple, RTD, resistance or voltage range to its field sensor and wiring method.
- For redundant operation, configure and validate both partner modules as one approved I/O pair.