Specifications
|
Parameter |
Value |
|
Model |
S200-IE8 S200IE8 |
|
Product Type |
Analog Input Unit |
|
Number of Inputs |
8 (single-ended) |
|
Galvanic Isolation |
Yes (via optocouplers) |
|
Status Indicator |
1 x Green LED (PWR) |
|
Resolution |
12-bit |
|
Input Current Range |
4–20 mA / 0–20 mA |
|
Input Voltage Range |
2–10 V DC / ±10 V DC / 0–10 V DC |
|
Input Resistance (Voltage) |
200 kΩ |
|
Input Resistance (Current) |
238 Ω |
|
Filter |
First-order low-pass, 100 ms time constant |
|
Non-linearity (Current) |
≤0.10% |
|
Non-linearity (Voltage) |
≤0.05% |
|
Accuracy (Voltage) |
±0.2% FS @ 25°C |
|
Accuracy (Current) |
±0.2% FS @ 25°C |
|
Temp Drift (Voltage) |
±0.0043% FS/°C |
|
Temp Drift (Current) |
±0.0041% FS/°C |
|
Repeatability |
±0.05% FS |
|
Overload (Voltage) |
30 V DC continuous |
|
Overload (Current) |
32 mA continuous (one channel max) |
|
Isolation Voltage |
850 V DC (1 s, plant to system) |
|
Internal Bus Current Consumption |
≤20 mA |
|
Power Dissipation |
3 W @ 31.2 V DC max |
|
External Power Supply |
24 V DC nominal (19.2–31.2 V DC) |
|
Supply Current |
60 mA @ 24 V DC (typ.) |
|
Operating Temperature |
0 °C to +55 °C |
|
Storage Temperature |
-40 °C to +85 °C |
|
Humidity (Operating) |
5–95% non-condensing |
|
Humidity (Storage) |
5–80% non-condensing |
|
Certifications |
CSA Class I Div 2 (Groups A–D, T6), European Ex Zone 2 Group IIC |
|
Unit Identity Code |
1924 (hex) |
|
Backplane Key Code |
3 |
|
Weight |
0.085 kg (net), 0.180 kg (gross) |
|
Dimensions |
94 x 46 x 53 mm |
Description
The ABB S200-IE8 S200IE8 is an 8-channel analog input module designed for industrial automation. Belonging to the classic S200 I/O system, it can process 0-20mA, 4-20mA, or 0-10V current/voltage signals with high precision. This module features 12-bit high resolution, electrical isolation, and a compact, hot-swappable design. It is widely used in Advant OCS and AC800M control systems, ensuring real-time data acquisition and interference immunity in environments such as power and chemical industries.
Applications
Fine chemical plants: Monitoring reactor pressure, liquid level, and feed flow rate.
Wastewater treatment plants: Collecting water quality monitoring data (pH, turbidity) and pump station outlet pressure signals.
Paper and packaging plants: Monitoring pulp concentration, drying roller temperature, and conveyor line speed.
Food processing plants: Used for temperature compensation in aseptic filling lines and tank weighing systems.
Coal power plants: Acquiring operational data for auxiliary systems (such as desulfurization and water treatment).
Features
Replacement under system power
CE and UL approvement
Software configurable function
Mechanical coding for safe replacement
Safety function on outputs in remote configuration
Variety of termination options
The same I/O units in central andremote configurations
Compatible with I/O 200C
Troubleshooting
PWR LED is not lit
1. Check 24 V DC
2. Check wiring for 24 V DC
3. Replace the unit.
A break in a 4–20 mA loop is detected by the system
1. Check cabling and connections.
2. Check the sensor.
3. Check the value at the terminal base unit.(1)
4. Check that the correct type of input is selected in
the hardware configuration editor.
5. Replace the unit.
FAQ
Q1: Does the S200-IE8 S200IE8 module require an independent power supply?
Yes, it typically requires an external 24V DC power supply via a terminal block to power its internal circuitry and some sensors.
Q2: How do I configure the signal type for each channel (e.g., 4–20mA) on the S200-IE8 S200IE8?
Configure it parametrically through the software of the connected controller (e.g., AC800M). No hardware jumper adjustments are needed.
Q3: What should I do if a channel on the S200-IE8 S200IE8 displays the maximum range and doesn't change?
First, measure the current at the terminal. If the current is normal but the data is abnormal, try changing the slot or module; if there is no current, check the sensor and circuitry.
Q4: On which sockets can the S200-IE8 S200IE8 module be installed?
It is typically installed on S200 series dedicated terminal blocks such as B12, B24, or B24T.
Q5: What does the 12-bit resolution of the S200-IE8 S200IE8 mean?
This means it can divide the input range (such as 0–20mA) into 4096 parts and identify minute changes of about 0.005mA.