Mitsubishi Electric QD75M4 MELSEC-Q Four-Axis SSCNET Positioning Module
Manufacturer: Mitsubishi Electric
Condition: Brand New
Lead Time: In Stock
Origin: Japan
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Use the SSCNET amplifier and cable combinations specified for QD75M.
- Prepare GX Configurator-QP and a suitable PLC engineering connection.
- Allocate 32 intelligent-function I/O points.
- Order A6CON1, A6CON2, A6CON3 or A6CON4 separately.
- Keep SSCNET cabling within the 30 m overall limit.
- Provide external stop and interlock circuits and commission movement at a controlled low speed.
QD75M4 MELSEC-Q Four-Axis SSCNET Positioning Module
A four-axis positioning module using SSCNET, with linear and circular interpolation and flash-backed positioning data.
At a Glance
| Brand | Mitsubishi Electric |
|---|---|
| Model | QD75M4 |
| Product Type | Intelligent positioning module |
| Core Function | Controls coordinated servo positioning |
| Application | MELSEC-Q motion-control stations |
Coordinated motion
Supports linear interpolation across two, three or four axes.
Stored motion data
Provides 600 positioning data items per axis.
Servo network
Connects supported servo amplifiers over SSCNET.
Product Overview
QD75M4 provides four-axis SSCNET positioning for a MELSEC-Q control system.
The module combines point-to-point, path and speed-related control with machine origin return and manual movement functions, while parameters and positioning data can be retained in flash ROM.
Key Functions
Interpolated positioning
Two-, three- and four-axis linear interpolation and two-axis circular interpolation support coordinated machine movement.
Motion profiles and manual operation
Trapezoidal and S-pattern acceleration/deceleration complement speed control, origin return, JOG and manual pulse-generator operation.
Data preparation and backup
GX Configurator-QP and the PLC program can prepare positioning data, and parameters, positioning data and block-start data can be stored in flash ROM.
Official Specifications
| Controlled axes | 4 |
|---|---|
| Interpolation | 2-, 3- and 4-axis linear; 2-axis circular |
| Control modes | PTP, path, speed, speed-position switching and position-speed switching |
| Engineering units | mm, inch, degree or PLS |
| Positioning data capacity | 600 items per axis |
| Linear speed command | 0.01–20,000,000.00 mm/min |
| Pulse-unit speed command | 1–10,000,000 PLS/s |
| Acceleration and deceleration profiles | Trapezoidal or S-pattern |
| Acceleration and deceleration time | 1–8,388,608 ms; 4 patterns for each |
| Sudden-stop deceleration time | 1–8,388,608 ms |
| Data backup medium | Flash ROM for parameters, positioning data and block-start data |
| Maximum flash write count | 100,000 writes |
| External wiring connector | 40-pin |
| Maximum SSCNET overall cable length | 30 m |
| Internal current consumption | 0.40 A at 5 V DC |
| Occupied I/O points | 32 intelligent-function module points |
| Dimensions (W × H × D) | 27.4 × 98 × 90 mm |
| Weight | 0.16 kg |
Frequently Asked Questions
Can QD75M4 interpolate all four axes together?
The module supports four-axis linear interpolation as well as two- and three-axis linear interpolation and two-axis circular interpolation.
Which setup tool should I prepare for QD75M4?
Use GX Configurator-QP to configure and handle the module’s positioning settings and data.
Which connector is required for the external signals of QD75M4?
Use an A6CON1, A6CON2, A6CON3 or A6CON4 external connector, which is sold separately.
Can QD75M4 connect to an MR-J2S-B amplifier?
The SSCNET connection to an MR-J2S-B amplifier uses an MR-J2HBUS cable of the appropriate length.
How much PLC I/O space should I reserve for QD75M4?
Allocate 32 points as an intelligent-function module in the I/O assignment.
How can I retain the motion setup in QD75M4 without a battery?
Save the parameters, positioning data and block-start data to the module’s flash ROM.
How long can the SSCNET cabling connected to QD75M4 be?
Keep the overall SSCNET cable length within 30 m.