Siemens 6ES7193-6BP00-0DA0 SIMATIC ET 200SP BU15-P16+A0+2D BaseUnit

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIEMENS SIMATIC ET 200SP

6ES7193-6BP00-0DA0 SIMATIC ET 200SP BU15-P16+A0+2D BaseUnit

A light-colored A0 BaseUnit with 16 push-in process terminals, two supply-bus connections and an integrated filter for a separately supplied ET 200SP load group.

At a Glance

Brand Siemens
Model 6ES7193-6BP00-0DA0
Product Type A0 BaseUnit
Core Function Starts a new station load group
Application Compatible ET 200SP I/O modules

Separate load-group supply

The light-colored base opens a new potential group.

Direct process wiring

Sixteen push-in process terminals connect the I/O module.

No auxiliary row

This compact version has no AUX or add-on terminals.

Product Overview

6ES7193-6BP00-0DA0 forms a new ET 200SP load group using the BU15-P16+A0+2D terminal arrangement.

Its integrated filter, separate potential-group supply and optional shield connection support a compact 15 mm wiring position without an additional auxiliary terminal row.

Ordering focus: Use the light-colored new-group arrangement where a fresh supply is required, and account for the absence of AUX and add-on terminals.
Key Functions

Separate the next potential group

The BaseUnit starts a new group rather than bridging the supply from the group on its left.

Connect the I/O signals and supply

Sixteen process terminals and two P1/P2 supply connections provide the module wiring points.

Integrate supply filtering

An integrated filter is included, and a system-integrated shield connection can be added as an option.

Official Specifications
Rated Supply Voltage 24 V DC
Process-Terminal Arrangement 16 push-in terminals; no AUX or add-on terminals
Supply-Bus Connections Two terminals connected to P1 and P2
Maximum P1/P2 Bus Current 10 A
Maximum Process-Terminal Current 2 A
Supply-Line Protection 24 V DC, 10 A miniature circuit breaker with B or C characteristic
Insulation Type-Test Voltage 707 V DC
Conductor Cross-Section 0.14–2.5 mm² (AWG 26–14)
Horizontal Operating Temperature −30 to +60 °C
Vertical Operating Temperature −30 to +50 °C
Maximum Installation Altitude 5,000 m; restrictions apply above 2,000 m
Minimum Dew Point −60 °C, for dry-room applications
Process-Terminal Color Labels CC00–CC09
Overall Dimensions 15 × 117 × 35 mm (W × H × D)
Approximate Weight 40 g
Frequently Asked Questions

Should I use 6ES7193-6BP00-0DA0 to continue the load group on the left?

This light-colored BaseUnit starts a new potential group instead of continuing the group on its left.

Can I land additional AUX wires on 6ES7193-6BP00-0DA0?

The base has neither AUX terminals nor add-on terminals.

How do I protect the supply lines feeding 6ES7193-6BP00-0DA0?

Use a 24 V DC, 10 A miniature circuit breaker with a B or C tripping characteristic.

What is the difference between the bus and process limits on 6ES7193-6BP00-0DA0?

The P1/P2 buses carry up to 10 A, while each process terminal is limited to 2 A.

Can I add a shield connection to 6ES7193-6BP00-0DA0?

A system-integrated shield connection is available as an option.

Which conductor range fits the push-in terminals of 6ES7193-6BP00-0DA0?

The terminals accept 0.14–2.5 mm² conductors, corresponding to AWG 26–14.

What temperature limit changes when I mount 6ES7193-6BP00-0DA0 vertically?

The operating range is −30 to +50 °C vertically compared with −30 to +60 °C horizontally.

Compatibility & Ordering Notes
Before ordering 6ES7193-6BP00-0DA0: Select the A0 new-group base with the required 16 process connections, and provide separate supply protection for the new group.

Compatibility Checklist for 6ES7193-6BP00-0DA0

  • Use an ET 200SP I/O module approved for BU type A0.
  • Select the light-colored new-group arrangement in the station configuration.
  • Provide the separate 24 V DC feed and B- or C-characteristic supply protection.
  • Keep the 10 A bus and 2 A process-terminal limits distinct.
  • Add the optional shield connection only where the installation requires it.
  • Apply the temperature and altitude restrictions for the actual mounting location.
Hot Selling Models
7000-12021-2340750
3RT2015-2BB41
3TH4394-0A
3LD2054-1TP51
7700-A3021-U1B0200
3RT1016-1CN25 3RH1911-1HA22 3RT1916-1BD00
OR0009/ORR-V/ORT-V
GV-NX72G512P2
ADN4030IPPSA
C21084502
FAZ-2-D16
DSNU-25-10-PA
TS30-15P-1
ABB ESB 24-04 230-240V
819-FR-60-101-FD