Overview
Place of Origin: |
USA |
Brand Name: |
Bently Nevada |
Model Number: |
9200-06-05-05-00 |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
5-7 days |
Payment Terms: |
T/T |
Supply Ability: |
In stock |
Quick Detail
|
Transducer Mounting Angle/Minimum Operating Frequency Option |
0 ±100, 10 Hz (600 cpm) |
|
Connector/Cable Option |
Terminal block top mount (no cable) |
|
Mounting Base Option |
No base; 1/2-20 UNF-3A stud |
|
Agency Approval Option |
No Approvals |
|
Dimension: |
4x4x9.2cm |
|
Weight: |
0.3 kg |
Description
The 9200-06-05-05-00 Two-wire Transducer from Bently Nevada™ is a moving-coil Seismoprobe velocity sensor designed for absolute vibration measurement of bearing housings, casings, and structural equipment in industrial automation systems. The 9200-06-05-05-00 Two-wire Transducer delivers 20 mV/mm/s (500 mV/in/s) sensitivity ±5% with a 10 kΩ calibration load, ensuring accurate velocity output directly proportional to vibration level. With a frequency response from 10 Hz (600 cpm) to 1 kHz (60,000 cpm) and amplitude linearity within ±5% from 0.01 to 5.0 in/s at 100 Hz, the 9200-06-05-05-00 Two-wire Transducer supports precise machine condition monitoring.
The 9200-06-05-05-00 Two-wire Transducer operates from -29°C to +121°C and withstands 50 g peak shock along the non-sensitive axis, making it suitable for demanding industrial environments up to 2000 m altitude and 95% non-condensing humidity. Coil resistance is 1.25 kΩ ±5%, and sensitivity temperature coefficient is 0.2%/°C. Featuring a 1/2-20 UNF-3A stud mount and terminal block top connection, the 9200-06-05-05-00 Two-wire Transducer requires no external power, enabling direct integration with monitoring and diagnostic instruments for continuous or periodic vibration measurement in automation applications.
Applications
Hydroelectric Power: Low-Speed Rotation Equipment Monitoring: Hydro turbines typically operate at low speeds, making the 9200 series (frequency range down to 4.5Hz or 10Hz) ideal for monitoring oscillation and bearing vibration in large hydro turbine generator sets.
Oil & Gas: Reciprocating Compressors: Used to monitor vibrations in compressor cylinders, bodies, or crossheads. Their robust internal structure withstands the continuous impacts of reciprocating motion.
Centrifugal Pumps and Condensate Pumps: In refineries and gas processing plants, to capture vibration signals in real time caused by bearing failure, misalignment, or loosening.
Steel & Heavy Industry: Large Fans and Blowers: Monitor large fan systems in steel plant blast furnace blowers or sintering machines to prevent catastrophic failures caused by uneven blade ash accumulation.
Crushers and Mills: Used in mines or cement plants to monitor the mechanical health of heavy-duty crushing equipment.
Specifications
|
Sensitivity |
20 mV/mm/s (500 mV/in/s), ±5% when properly terminated and oriented at the angle of calibration. |
|
Calibration Load |
10 kΩ Terminal "A" to "B" Output taken across pins "A" and "B |
|
Sensitivity Temperature Coefficient |
0.2%/°C |
|
Frequency response |
From minimum operating frequency (see Ordering Information) to 1 kHz (60,000 cpm); +0, -3dB typical. |
|
Velocity Range |
25 mm/s (1 in/s) (at +22 °C of casing vibration at 100 Hz with a 10 kΩ load. |
|
Coil Resistance |
1.25 kΩ ±5% |
|
Amplitude Linearity |
±5% from 0.01 to 5.0 in/s (0.254 to 127 mm/s) at 100Hz (6000CPM) |
|
Shock resistance |
Withstands 50 g peak maximum acceleration along non-sensitive axis. |
|
Transverse sensitivity |
±10% maximum of the sensitive axis sensitivity at 100 Hz and 1.0 in/s (2.54 cm/s) |
|
Operating and Storage Temperature |
-29°C to +121°C (-20°F to +250°F). |
|
Environment |
Dust and moisture resistant. |
|
Relative Humidity |
To 95%, noncondensing. 100%, non-submerged, when ordered with integral cable. |
|
Maximum Use Altitude |
2000 m (6,561 ft) above sea level. |
|
Case and Adapter Material |
Anodized aluminum A204 |
|
Gasket Material |
Neoprene |
|
Connector Material(Top and Side Mount Options) |
Cadmium-plated aluminum, neoprene, and silver-plated copper |
|
Connector Material(Terminal Block Option) |
Polyphenylene Sulfide with nickel-plated copper contacts. |
Competitive Advantage
High Accuracy Velocity Measurement
The 9200-06-05-05-00 Two-wire Transducer provides precise velocity output with ±5% linearity and frequency response up to 1 kHz, enabling automation systems to detect early-stage vibration anomalies.
Easy Integration with Automation Systems
No external power is required for the 9200-06-05-05-00 Two-wire Transducer, allowing direct connection to monitoring or diagnostic instruments, including portable or continuous measurement setups.
Withstands Harsh Industrial Conditions
The 9200-06-05-05-00 Two-wire Transducer operates across -29°C to +121°C, handles 95% non-condensing humidity, and resists shock up to 50 g, allowing reliable deployment in industrial vibration monitoring applications.
Flexible Mounting Options
With a 1/2-20 UNF-3A stud mount and terminal block top connector, the 9200-06-05-05-00 Two-wire Transducer can be securely mounted on machinery or structural components, supporting both permanent and temporary installations.