Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
tu846 3bse022460r1module termination unit-0

For ABB

Home >  Products >  For ABB

TU846 3BSE022460R1 Module Termination Unit

  • Overview
  • Specifications
  • Description
  • Environment and certification
  • Applications
  • Features and benefits
  • FAQ
  • Recommended Products
Overview

Place of Origin:

Sweden

Brand Name:

ABB

Model Number:

TU846 3BSE022460R1

Packaging Details:

Original new Factory Sealed

Delivery Time:

5-7 days

Payment Terms:

T/T

Supply Ability:

In stock

Specifications

Parameter

Value

Model

TU846 3BSE022460R1

Module Type

Redundant CI840/CI840A, Redundant I/O

Communication protocol

PROFIBUS DP-V1

Master or slave

N/A

Line redundancy

Yes

Module redundancy

Yes

Hot Swap

No

Power input

24 V d.c. (19.2 - 30 V)

Mounting

Vertical or Horizontal

Connector

PROFIBUS: DSUB9 connector; Service ports: RJ45 connector

ModuleBus current distribution

Maximum 5 V 1.5 A, Maximum 24 V 1.5 A

Mechanical Keys

36 different combinations

Acceptable wire sizes

0.25 - 2.5 mm², 24 - 14 AWG

Recommended torque

0.5 - 0.6 Nm

Stripping length

6 - 7.5 mm (0.24 - 0.30 in)

Rated insulation voltage

50 V

Dielectric test voltage

500 V a.c.

Width

124 mm (4.88)

Height

186 mm (7.32) including latch

Depth

47 mm (1.85)

Weight

0.5 kg (1.1 lbs.)

Description

The TU846 3BSE022460R1 is a module termination unit (MTU) for redundant configuration of the field communication interface CI840/CI840A and redundant I/O. The MTU is a passive unit having connections for power supply, two electrical ModuleBuses, two CI840/CI840A and two rotary switches for station address (0 to 99) settings.

A ModuleBus Optical Port TB842 can be connected to TU846 via TB846. Four mechanical keys, two for each position, are used to configured the MTU for the right types of modules. Each key has six positions, which gives a total number of 36 different configurations.

Module Termination Unit for dual CI840/CI840A, redundant I/O. TU846 are used with redundant I/O modules and TU847 with single I/O modules. The maximum ModuleBus length from the TU846 to the ModuleBus terminator is 2.5 meters. TU846/TU847 needs space to the left in order to be removed. Cannot be replaced with power applied.

Environment and certification

Parameter

Value

CE mark

Yes

Electrical safety

EN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201

Hazardous location

cULus Hazardous Location Class1 Zone 2, ATEX Zone 2

Temperature, Operating

0 to +55 °C (+32 to +131 °F), approvals are issued for +5 to +55 °C

Temperature, Storage

-40 to +70 °C (-40 to +158 °F)

Relative humidity

5 to 95 %, non-condensing

Max ambient temperature

55 °C (131 °F), for vertical mounting 40 °C (104 °F)

Equipment class

Class I according to IEC 60536 (earth protected)

Ingress protection

IP20 according to IEC 529, (IEC 144)

RoHS compliance

EU RoHS, UAE RoHS, CN RoHS

WEEE compliance

DIRECTIVE/2012/19/EU

Applications

Oil and gas plants: Ensure uninterrupted fieldbus communication over long distances and across multiple sites.

Large chemical plants: Guarantee the transmission of safety-critical data within redundant systems.

Power plants/substations: Used in complex DCS monitoring networks.

Steel and metallurgical plants: Provide a stable communication interface foundation in harsh electromagnetic interference environments.

Pharmaceutical plants: Support high-precision, high-reliability production process control.

Features and benefits

Power supply connection.

Two PROFIBUS connections.

Two service tool connections.

Two rotary switch for station address setting.

Connection for two ModuleBuses.

Connector for ModuleBus Optical Port.

Mechanical keying prevents insertion of the wrong module type.

Latching device to DIN rail for locking and grounding.

DIN rail mounted.

FAQ

Q: Can the TU846 3BSE022460R1 be replaced while running like the TU845?
A: No. The TU846 3BSE022460R1 does not support hot-swapping and must be installed or replaced while the power is off.

Q: How many CI840 modules can be installed in one TU846 3BSE022460R1?
A: It is designed for redundancy and can accommodate 2 CI840/CI840A modules.

Q: Are there any special space requirements for installing the TU846 3BSE022460R1?
A: Yes. Due to its structural design, the TU846 3BSE022460R1 requires sufficient space on the left side to be easily removed from the rails during disassembly.

Q: Does the TU846 3BSE022460R1 come with a ModuleBus terminating resistor?
A: The standard package typically includes two TB807 module bus terminating resistors to complete the physical closed loop of the communication bus.

Q: Why can't I insert my CI840 module into the TU846 3BSE022460R1?
A: Please check the positions of the four mechanical keys on the TU846 3BSE022460R1. They must be set to the encoding that matches the target module; otherwise, the error-proofing mechanism will prevent insertion.

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.