Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
tu845 3bse021447r1module termination unit-0

For ABB

Home >  Products >  For ABB

TU845 3BSE021447R1 Module Termination Unit

  • Overview
  • Specifications
  • Description
  • Environment and certification
  • Applications
  • Features and benefits
  • FAQ
  • Recommended Products
Overview

Place of Origin:

Sweden

Brand Name:

ABB

Model Number:

TU845 3BSE021447R1

Packaging Details:

Original new Factory Sealed

Delivery Time:

5-7 days

Payment Terms:

T/T

Supply Ability:

In stock

Specifications

Parameter

Value

Model

TU845 3BSE021447R1

Type

Redundant

Connection

Terminal block

Channels

8

Voltage

50 V

Mounting

Vertical

Mounting detail

55 º (131 °F)

Compatible I/O

AI845, AI880, AI880A, DP840

Process connections

40 up to 8 I/O channels (2 terminals per channel), 4 Process power, 20 Process power (0 V)

Single/redundant I/O

Redundant

Max current per I/O channel

2 A

Max current process connection

5 A

Acceptable wire sizes

Solid: 0.2 - 4 mm²; Stranded: 0.2 - 2.5 mm², 24 - 12 AWG

Recommended torque

0.5 - 0.6 Nm

Stripping length

7 mm

Dielectric test voltage

500 V a.c.

Width

131 mm (5.16”) including connector, 124 mm (4.88”) edge to edge installed

Depth

64 mm (2.52”) including terminals

Height

186.5 mm (7.34”) including locking device

Weight

0.6 kg (1.3 lbs.)

Description

The TU845 3BSE021447R1 MTU can have up to 8 I/O channels and 2+2 process voltage connections. Each channel has two I/O connections and one ZP connection. Input signals are connected via individual shunt sticks, TY801. The shunt stick is used to choose between voltage and current input. The maximum rated voltage is 50 V and maximum rated current is 2 A per channel.

The MTU distributes the two ModuleBuses, one to each I/O module and to the next MTU. It also generates the correct address to the I/O modules by shifting the outgoing position signals to the next MTU. It has a mechanical latch that locks the MTU to the DIN rail.

Four mechanical keys, two for each I/O module, are used to configure the MTU for different types of I/O modules. This is only a mechanical configuration and it does not affect the functionality of the MTU or the I/O module. Each key has six positions, which gives a total number of 36 different configurations.

Environment and certification

Parameter

Value

CE mark

Yes

Electrical safety

EN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201

Hazardous Location

C1 Div 2 cULus, C1 Zone 2 cULus, ATEX Zone 2

Marine certification

-

Temperature, Operating

0 to +55 °C (+32 to +131 °F), approvals are issued for +5 to +55 °C

Temperature, Storage

-40 to +70 °C (-40 to +158 °F)

Pollution degree

Degree 2, IEC 60664-1

Corrosion protection

ISA-S71.04: G3

Relative humidity

5 to 95 %, non-condensing

Max ambient temperature

55 °C (131 °F)

Protection class

IP20 according to IEC 60529

Mechanical operating conditions

IEC/EN 61131-2

EMC

EN 61000-6-4, EN 61000-6-2

Overvoltage categories

IEC/EN 60664-1, EN 50178

Equipment class

Class I according to IEC 61140 (earth protected)

RoHS compliance

EN 50581:2012

WEEE compliance

DIRECTIVE/2012/19/EU

Applications

Chemical plants: Precise opening control of reactor regulating valves to ensure safe chemical reactions.

Oil refineries: Pressure regulation and flow control of crude oil transportation pipelines.

Power plants: Actuator drive for turbine bypass systems or feedwater pumps.

Paper mills: Proportional valve drive for pulp proportioning control systems.

Wastewater treatment plants: Redundant control of large water pump frequency converter signals.

Features and benefits

Complete installation of I/O modules using 2-wire connections and field power distribution.

Up to 8 channels of field signals and process power connections.

Connections to two ModuleBuses and I/O modules.

Mechanical keying prevents insertion of the wrong I/Omodule.

Latching device to DIN rail for grounding.

DIN rail mounting.

FAQ

Q: How many signal connections does the TU845 3BSE021447R1 support?
A: It provides 3 sets of 25 screw terminals each, primarily for interfacing with two redundant I/O modules.

Q: What is the maximum voltage the TU845 3BSE021447R1 terminal unit can handle?
A: Its rated isolation voltage is up to 50V DC.

Q: If one of the I/O modules fails, can I simply unplug it from the TU845 3BSE021447R1?
A: Yes, the TU845 3BSE021447R1 supports hot-swapping of modules without affecting the normal operation of the other redundant module.

Q: What is the difference between the TU845 3BSE021447R1 and TU844?
A: The TU845 3BSE021447R1 is specifically designed for connecting redundant I/O modules, while standard models typically support only a single module.

Q: Are there any orientation requirements for installing the TU845 3BSE021447R1?
A: It supports horizontal or vertical mounting on DIN rails, but ensure that the ventilation space meets the manual requirements.