Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
200350 02 00 cn accelerometer -0

3300 System

Home >  Products >  For Bently Nevada >  3300 System

200350-02-00-CN Accelerometer

  • Overview
  • Quick Detail
  • Description
  • Applications
  • Specifications
  • Competitive Advantage
  • Recommended Products
Overview

Place of Origin:

USA

Brand Name:

Bently Nevada

Model Number:

200350-02-00-CN

Minimum Order Quantity:

1

Packaging Details:

Original new Factory Sealed

Delivery Time:

5-7 days

Payment Terms:

T/T

Supply Ability:

In stock

Quick Detail

Mounting Stud :

¼-28 to M8 x 1.25 Stainless Steel

Tolerance:

100 mV/g ± 20% (10.2 mV/m/s^2 ±20%)

Approvals:

CSA, ATEX, IECEx

Dimension:

2x2x4.6cm

Weight:

0.06 kg

Description

The 200350-02-00-CN Accelerometer is a rugged, industrial-grade piezoelectric vibration transducer designed for precision automation and condition monitoring applications. Housed in a hermetically sealed stainless steel case, this accelerometer withstands harsh environments with operating temperatures from -54°C to +121°C (-65°F to +250°F) and shock survivability up to 5,000 g pk. It features a top-mounted 2-pin MIL-C5015 connector for straightforward installation and a ¼-28 to M8 x 1.25 mounting stud for flexible mounting options. With a sensitivity of 100 mV/g ±20% (10.2 mV/m/s² ±20%) and a broad frequency response from 0.5 Hz to 10,000 Hz, it provides highly accurate acceleration measurements up to ±50 g. The accelerometer delivers a low-noise differential voltage output with transverse sensitivity under 7% and amplitude linearity within ±1%, making it ideal for integration with Trendmaster Pro Constant Current Direct Input Cards (part 149811-02) and Seismic Direct Input Cards (part 164746-01). Its fast settling time of ≤2.0 seconds ensures rapid response in automated monitoring systems, enabling real-time vibration and condition analysis critical for predictive maintenance in industrial automation.

Applications

1. Vibration Monitoring in Rotating Equipment
Used on turbines, motors, and pumps, the 200350-02-00-CN accelerometer detects vibration in the ±50 g range with ≤7% transverse sensitivity, providing precise data for automated condition monitoring.

2. Predictive Maintenance in Industrial Automation
Integration with Trendmaster Pro Direct Input Cards allows real-time automated analysis of machinery health, reducing unplanned downtime and optimizing maintenance schedules.

3. Structural Health Monitoring
Monitors industrial structures or mounting surfaces for vibrations within 0.5–10,000 Hz, supporting automated alerts for resonance or mechanical imbalance.

4. Harsh Environment Performance
Operates reliably from -54°C to +121°C and survives shocks up to 5,000 g pk, suitable for automation systems in petrochemical, mining, or heavy machinery plants.

5. High-Frequency Signal Measurement
Capable of capturing vibrations up to 25 kHz (mounted resonant frequency), supporting high-speed automated diagnostics of rotating machinery and critical processes.

Specifications

Sensitivity:

100 mV/g ±20% (10.2 mV/m/s^2 ±20%)

Frequency Range (±3 dB) :

30-600,000 cpm (0.5- 10,000 Hz)

Measurement Range:

± 50 g

Transverse Sensitivity:

≤ 7%

Amplitude Linearity :

± 1%

Mounted Resonant Frequency:

1500 kcpm (25 kHz)

Broadband Electrical Noise (1-10kHz) :

350 µg (3,434 µm/s2)

Output Bias Voltage:

8 to 12 VDC

Excitation Voltage:

18 to 28 VDC

Constant Current Excitation

2 to 20 mA

Settling Time (within 1% of bias)

≤ 2.0 sec

Operating Temperature Range

-65°F to +250 ºF (-54°C to +121 ºC)

Shock Survivability

5,000 g pk

Competitive Advantage

1. Extreme Ruggedness
Hermetically sealed stainless steel casing provides durability in harsh industrial environments, ensuring long-term reliability for automated systems.

2. High Sensitivity and Accuracy
100 mV/g ±20% sensitivity with amplitude linearity ±1% enables precise vibration measurement, critical for predictive maintenance and process control automation.

3. Flexible Mounting Options
¼-28 to M8 x 1.25 threaded stud allows secure installation in multiple orientations, supporting versatile automation and sensor deployment.

4. Low Electrical Noise
Broadband electrical noise of 350 µg (3,434 µm/s²) minimizes signal interference, ensuring high-quality vibration data for automated monitoring systems.

5. Rapid Settling and Response
Settling time ≤2.0 seconds allows fast real-time readings, enhancing automation performance in machinery diagnostics, safety monitoring, and control loops.