- Overview
- Specifications
- Description
- Applications
- Troubleshooting & Diagnostics
- FAQ
- Recommended Products
Overview
Place of Origin: |
USA |
Brand Name: |
ICS TRIPLEX |
Model Number: |
TC-801-02-4M5 |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
5-7 days |
Payment Terms: |
T/T |
Supply Ability: |
In stock |
Specifications
|
Model |
TC-801-02-4M5 |
|
Product Type |
Trusted Special I/O Cable |
|
Length |
4.5 m |
|
Application |
Must be used with T8442 Speed Monitor (speed/rotation monitoring module) |
|
Maximum Working Voltage |
60 V |
|
Maximum Current per Channel |
2 A |
|
Cable Type |
LSZH (Low Smoke Zero Halogen) |
|
Cable Construction |
Screened twisted pairs |
|
Chassis End Connector |
1 × 96-way ‘C’ connector (double-width hood protection) |
|
Intermediate Connectors |
6 × 20-way screw-fixed terminal connectors |
|
FTA Interface |
3 × connections to T8846 Speed Input FTA; 3 × connections to up to 3 × T8891 Speed Output FTA |
|
Certifications |
Ord, HazLoc, ATEX, IECEx |
|
Flame Rating |
IEC 60332-3 Cat A |
|
Operating Temperature |
0 to +60 °C (32 to +140 °F) |
|
Installation Type |
Chassis to Field Terminal Assembly Interconnection |
Description
The TC-801-02-4M5 is a Trusted Special I/O Cable primarily used for critical signal transmission between the speed monitoring module and the field terminal block (FTA). This cable is made of low-smoke halogen-free (LSZH) environmentally friendly material and meets high flame retardant standards, making it suitable for hazardous and explosive operating environments equipped with triple module redundancy (TMR).
Applications
Oil & Gas Refining Facilities: Used in refineries, offshore platforms, and pipeline hubs for critical interlock and safety signals.
Petrochemical & Chemical Plants: Installed in hazardous reactors and storage zones for stable safety logic transmission.
Thermal & Nuclear Power Plants: Applied in boiler safety systems and turbine trip protection networks.
Rail Transit & Heavy Machinery Plants: Ensures reliable signal integrity in high vibration and strong EMI environments.
Troubleshooting & Diagnostics
Speed Signal Drift / Intermittent Loss: Inspect the 96-way 'C' chassis connector pins and ensure the double-width hood is fully seated. Check for ground loop shield breaks.
Screw Terminal Loose Faults: Check the six 20-way screw-locking terminal connectors if speed input or output values drop out. Tighten loose terminal screws.
Signal Cross-talk: Verify that the screening of the twisted pairs has not been damaged during routing, which could let electromagnetic interference compromise frequency readings.
FAQ
Q: Can TC-801-02-4M5 be used without a T8442 speed monitor module?
A: No. It must be used with the T8442 Speed Monitor module.
Q: How are the six 20-channel field connectors assigned in TC-801-02-4M5?
A: Three connect to T8846 speed input FTA, and three to up to three T8891 speed output FTAs.
Q: Why does TC-801-02-4M5 use screened twisted pair design?
A: To block high-frequency noise and ensure accurate speed signal transmission.
Q: What is the meaning of IEC 60332-3 Cat A for TC-801-02-4M5?
A: High-level fire resistance with strong self-extinguishing performance in bundled cables.
Q: What are the voltage and current limits of TC-801-02-4M5?
A: Maximum 60V and 2A per channel.