Overview

Place of Origin:

USA

Brand Name:

ICS TRIPLEX

Model Number:

TC-801-02-4M5

Packaging Details:

Original new Factory Sealed

Delivery Time:

5-7 days

Payment Terms:

T/T

Supply Ability:

In stock

Specifications

Model

TC-801-02-4M5

Product Type

Trusted Special I/O Cable

Length

4.5 m

Application

Must be used with T8442 Speed Monitor (speed/rotation monitoring module)

Maximum Working Voltage

60 V

Maximum Current per Channel

2 A

Cable Type

LSZH (Low Smoke Zero Halogen)

Cable Construction

Screened twisted pairs

Chassis End Connector

1 × 96-way ‘C’ connector (double-width hood protection)

Intermediate Connectors

6 × 20-way screw-fixed terminal connectors

FTA Interface

3 × connections to T8846 Speed Input FTA; 3 × connections to up to 3 × T8891 Speed Output FTA

Certifications

Ord, HazLoc, ATEX, IECEx

Flame Rating

IEC 60332-3 Cat A

Operating Temperature

0 to +60 °C (32 to +140 °F)

Installation Type

Chassis to Field Terminal Assembly Interconnection

Description

The TC-801-02-4M5 is a Trusted Special I/O Cable primarily used for critical signal transmission between the speed monitoring module and the field terminal block (FTA). This cable is made of low-smoke halogen-free (LSZH) environmentally friendly material and meets high flame retardant standards, making it suitable for hazardous and explosive operating environments equipped with triple module redundancy (TMR).

Applications

Oil & Gas Refining Facilities: Used in refineries, offshore platforms, and pipeline hubs for critical interlock and safety signals.

Petrochemical & Chemical Plants: Installed in hazardous reactors and storage zones for stable safety logic transmission.

Thermal & Nuclear Power Plants: Applied in boiler safety systems and turbine trip protection networks.

Rail Transit & Heavy Machinery Plants: Ensures reliable signal integrity in high vibration and strong EMI environments.

Troubleshooting & Diagnostics

Speed Signal Drift / Intermittent Loss: Inspect the 96-way 'C' chassis connector pins and ensure the double-width hood is fully seated. Check for ground loop shield breaks.

Screw Terminal Loose Faults: Check the six 20-way screw-locking terminal connectors if speed input or output values drop out. Tighten loose terminal screws.

Signal Cross-talk: Verify that the screening of the twisted pairs has not been damaged during routing, which could let electromagnetic interference compromise frequency readings.

FAQ

Q: Can TC-801-02-4M5 be used without a T8442 speed monitor module?
A: No. It must be used with the T8442 Speed Monitor module.

Q: How are the six 20-channel field connectors assigned in TC-801-02-4M5?
A: Three connect to T8846 speed input FTA, and three to up to three T8891 speed output FTAs.

Q: Why does TC-801-02-4M5 use screened twisted pair design?
A: To block high-frequency noise and ensure accurate speed signal transmission.

Q: What is the meaning of IEC 60332-3 Cat A for TC-801-02-4M5?
A: High-level fire resistance with strong self-extinguishing performance in bundled cables.

Q: What are the voltage and current limits of TC-801-02-4M5?
A: Maximum 60V and 2A per channel.