For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIMATIC S7-400 6ES7416-3FS06-0AB0 CPU 416F-3 PN/DP

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview
Siemens SIMATIC S7-400

6ES7416-3FS06-0AB0 CPU 416F-3 PN/DP

Officially documented SIMATIC S7-400 component for failsafe S7-400 automation with PROFINET and PROFIBUS DP connectivity.

At a Glance

Brand / Manufacturer Siemens
Model / Article Number 6ES7416-3FS06-0AB0
Product Type CPU 416F-3 PN/DP
Core Function Full Siemens article number 6ES7416-3FS06-0AB0 for exact spare-part matching.
Application / Compatible Series SIMATIC S7-400

Exact Identification

Match the complete article number 6ES7416-3FS06-0AB0, photographed nameplate and installed firmware or hardware revision before replacement.

Interface Arrangement

Confirm one Ethernet/PROFINET interface and two RS485 interfaces for MPI/DP and PROFIBUS DP used by the installed project.

Configuration Check

Verify STEP 7 and the applicable failsafe engineering package for firmware V6.0 before commissioning.

Product Overview

Siemens SIMATIC S7-400 6ES7416-3FS06-0AB0 CPU 416F-3 PN/DP is an officially documented SIMATIC S7-400 product designed for failsafe S7-400 automation with PROFINET and PROFIBUS DP connectivity. Its article number identifies the exact hardware variant and should be matched in full when planning a replacement or spare.

The unit provides one Ethernet/PROFINET interface and two RS485 interfaces for MPI/DP and PROFIBUS DP. Engineering, firmware, memory, rack, field wiring and network settings must be checked against the active project before installation.

Ordering focus: confirm the complete article number, installed firmware and hardware configuration, project backup and interface parameters before replacement or commissioning.
Key Functions

Model-specific identification

Full Siemens article number 6ES7416-3FS06-0AB0 for exact spare-part matching.

System role

Designed for failsafe S7-400 automation with PROFINET and PROFIBUS DP connectivity.

Integrated communication

Provides one Ethernet/PROFINET interface and two RS485 interfaces for MPI/DP and PROFIBUS DP.

Engineering continuity

Check STEP 7 and the applicable failsafe engineering package for firmware V6.0.

Power planning

5 V DC backplane current 1.3 A typical, 1.5 A maximum; typical power loss 6.5 W

Official Specifications
CPU / Firmware CPU 416F-3 PN/DP / V6.0
Controller Class Failsafe SIMATIC S7-400 CPU
Work Memory 16 MB total: 8 MB code / 8 MB data
Bit / Word / Fixed-Point Operation Time 30 ns
Floating-Point Operation Time 90 ns
Integrated Interfaces 1 Ethernet/PROFINET; 2 RS485
Backplane Current at 5 V DC 1.3 A typical / 1.5 A maximum
Power Loss Typical 6.5 W
Dimensions (W × H × D) 50 × 290 × 219 mm
Weight Approx. 900 g
Official source: Siemens Industry Mall technical data for 6ES7416-3FS06-0AB0. Confirm the current edition and installed revision when engineering a replacement.
Frequently Asked Questions

Which safety-engineering environment should be prepared for 6ES7416-3FS06-0AB0?

Commission the fail-safe CPU within the approved SIMATIC S7-400F/H engineering and validation workflow.

How much program and data memory is available in 6ES7416-3FS06-0AB0?

The 16 MB work memory is divided equally into 8 MB for code and 8 MB for data.

Which communication paths can be connected directly to 6ES7416-3FS06-0AB0?

The hardware provides an Ethernet/PROFINET interface together with two RS-485 interfaces.

Which firmware baseline must match a replacement 6ES7416-3FS06-0AB0?

The documented hardware is associated with firmware generation V6.0; the configured firmware and safety project must be checked before exchange.

What backplane supply demand applies to 6ES7416-3FS06-0AB0?

Plan for about 1.3 A typical and 1.5 A maximum at 5 V DC, with roughly 6.5 W power loss.

How should engineers assess scan performance for 6ES7416-3FS06-0AB0?

Typical bit, word and fixed-point operations are 30 ns and floating-point operations are 90 ns.

What must be retained before recommissioning 6ES7416-3FS06-0AB0?

Retain the validated safety program, hardware configuration, network parameters, passwords and acceptance records.

Compatibility & Ordering Notes
Before ordering 6ES7416-3FS06-0AB0: match the complete Siemens article number and verify the installed SIMATIC S7-400 hardware, firmware and project data.

Fail-Safe CPU Commissioning Checklist for 6ES7416-3FS06-0AB0

  • Compare every character of the nameplate article number.
  • Confirm the firmware or hardware revision supported by the engineering project.
  • Check rack, connector, memory, power and environmental requirements.
  • Record addressing, station names, redundancy and network parameters before removal.
  • Keep a verified project backup and follow the official manufacturer installation instructions.
Hot Selling Models
330101-00-16-10-02-05
MINI-PS-100-240AC/24DC/1.3
CA10.A202
PSM24-12B
401391-01
HTE200E20C2
UM45-2FLK13/AB-1756
1C31234G01
IMC-21-S-SC 1201000210013
M600-WM9
N500W
181B0616 SPR-ELE21780
SB-DDP-EU/B
163 18 NH100
CCT551011

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.