Obtain a Free Quote

Our representative will contact you shortly.
Email
Nomen
Nomen societatis
Notula
0/1000

Siemens SIMATIC S7-400 6ES7416-3FS06-0AB0 CPU 416F-3 PN/DP

Fabricator: Siemens
Status: Novissimum
Tempus Expectatus: In Stoc
Origo: Germania
Praestatio: 12 menses

  • Praevisio
  • Productum Overview
  • Functiones Principales
  • Official Specifications
  • FREQUENTLY ASKED QUESTIONS
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Pròdòt ràccumandà
Praevisio
Siemens SIMATIC S7-400

6ES7416-3FS06-0AB0 CPU 416F-3 PN/DP

Officially documented SIMATIC S7-400 component for failsafe S7-400 automation with PROFINET and PROFIBUS DP connectivity.

At a Glance

Nomen commerciale / Fabricator Siemens
Model / Article Number 6ES7416-3FS06-0AB0
Product Type CPU 416F-3 PN/DP
Functio principalis Full Siemens article number 6ES7416-3FS06-0AB0 for exact spare-part matching.
Application / Compatible Series SIMATIC S7-400

Identificatio exacta.

Conform the complete article number 6ES7416-3FS06-0AB0, the photographed nameplate, and the installed firmware or hardware revision before replacement.

Arrangementum Interfacis

Confirm one Ethernet/PROFINET interface and two RS485 interfaces for MPI/DP and PROFIBUS DP used by the installed project.

Configuration Check

Verify STEP 7 and the applicable failsafe engineering package for firmware V6.0 before commissioning.

Productum Overview

Siemens SIMATIC S7-400 6ES7416-3FS06-0AB0 CPU 416F-3 PN/DP is an officially documented SIMATIC S7-400 product designed for failsafe S7-400 automation with PROFINET and PROFIBUS DP connectivity. Its article number identifies the exact hardware variant and should be matched in full when planning a replacement or spare.

The unit provides one Ethernet/PROFINET interface and two RS485 interfaces for MPI/DP and PROFIBUS DP. Engineering, firmware, memory, rack, field wiring, and network settings must be checked against the active project before installation.

Focus ordinandi: confirmare numerum articuli completum, firmwarum installatam et configurationem hardware, copiam securitatis proiecti et parametres interfaciei antequam substitutio vel inceptio fiat.
Functiones Principales

Identificatio specifica modello

Full Siemens article number 6ES7416-3FS06-0AB0 for exact spare-part matching.

Officium Systematis

Adaptatus pro automatione S7-400 absque defectu, cum connexione PROFINET et PROFIBUS DP.

Communicatio Integra

Praebet unam interfaciem Ethernet/PROFINET et duas interfacies RS485 pro MPI/DP et PROFIBUS DP.

Continuitas ingenieriae

Verifica STEP 7 et pachetum ingenieriae absque defectu applicabile pro firmware V6.0.

Planificatio potentiae

current backplane 5 V DC: 1.3 A typice, 1.5 A maxime; potestas amissa typice 6.5 W

Official Specifications
CPU / Firmware CPU 416F-3 PN/DP / V6.0
Classis Controlleris CPU SIMATIC S7-400 absque defectu
Memoria operativa 16 MB totalis: 8 MB codicis / 8 MB datorum
Tempus operationis bit / verbum / puncti fixi 30 ns
Tempus Operationis Puncti Fluctuantis 90 ns
Interfacies Integri 1 Ethernet/PROFINET; 2 RS485
Backplane Current at 5 V DC 1.3 A tipicu / 1.5 A maximu
Ammissio Potentiae Tipico 6.5 W
Dimensiones (L × H × D) 50 × 290 × 219 mm
Pondus Appr. 900 g
Fons officialis: Datis tecnicus de Siemens Industry Mall pro 6ES7416-3FS06-0AB0 . Confirmare editionem currentem et revisionem installatam dum substitutio progetur.
FREQUENTLY ASKED QUESTIONS

Quod ambientes de securitas-engineering debe parari pro 6ES7416-3FS06-0AB0?

Committite le CPU fail-safe intra le workflow approbato de engineering e validation de SIMATIC S7-400F/H.

Quantum memoria pro programma e datos es disponibile in 6ES7416-3FS06-0AB0?

Le memoria de laboro de 16 MB es divisa equaliter in 8 MB pro codice e 8 MB pro datos.

Quales caminos de communication pote connecter directemente a 6ES7416-3FS06-0AB0?

Le hardware provide un interfacie Ethernet/PROFINET insimul con duos interfacies RS-45.

Quale baselina de firmware debe concordar con un 6ES7416-3FS06-0AB0 de substitution?

The documented hardware is associated with firmware generation V6.0; the configured firmware and safety project must be checked before exchange.

What backplane supply demand applies to 6ES7416-3FS06-0AB0?

Plan for about 1.3 A typical and 1.5 A maximum at 5 V DC, with roughly 6.5 W power loss.

How should engineers assess scan performance for 6ES7416-3FS06-0AB0?

Typical bit, word and fixed-point operations are 30 ns and floating-point operations are 90 ns.

What must be retained before recommissioning 6ES7416-3FS06-0AB0?

Retain the validated safety program, hardware configuration, network parameters, passwords and acceptance records.

Compatibility & Ordering Notes
Before ordering 6ES7416-3FS06-0AB0: match the complete Siemens article number and verify the installed SIMATIC S7-400 hardware, firmware and project data.

Fail-Safe CPU Commissioning Checklist for 6ES7416-3FS06-0AB0

  • Compare omnis character de numero articuli tabellae nominis.
  • Confirmare revisionem firmware vel hardware quae ab opere technico supportatur.
  • Inspicere cuneum, coniunctionem, memoriam, potentiam et postulationes ambientales.
  • Notare adressationem, nomina stationum, redundantiam et parametres rete antequam removetur.
  • Servare copiam projecti verificatam et sequi officialia instructiones fabricantis pro installatione.
Hot Selling Models
330101-00-16-10-02-05
MINI-PS-100-240AC/24DC/1.3
CA10.A202
PSM24-12B
401391-01
HTE200E20C2
UM45-2FLK13/AB-1756
1C31234G01
IMC-21-S-SC 1201000210013
M600-WM9
N500W
181B0616 SPR-ELE21780
SB-DDP-EU/B
163 18 NH100
CCT551011

Obtain a Free Quote

Our representative will contact you shortly.
Email
Nomen
Nomen societatis
Notula
0/1000
email ireAdSummum

Evolo Automation non est distributor autorizatus, nisi aliter specificatum, representativus vel affinis fabricantis huius producti. Omnia nomina commercialia et documenta proprietatis sunt suorum dominorum respective et praebentur ad identificationem et informationem.