Overview

SIEMENS SIMATIC ET 200SP HA • ISOLATED HART ANALOG INPUT

6DL1134-6UD00-0PK0 AI 4xI 2-/4-wire HART ISOL HA Analog Input Module

A four-channel, channel-isolated current input module for ET 200SP HA stations with HART support and 2-wire or 4-wire transmitters.

At a Glance

Brand Siemens
Model 6DL1134-6UD00-0PK0
Product Type Analog input module
Core Function Isolated current acquisition with HART
Compatible Series SIMATIC ET 200SP HA

Four Current Inputs

Connects up to four analog current signals from 2-wire or 4-wire transmitters.

Channel Isolation

The four inputs are electrically isolated from one another and from the backplane and supply.

HART Integration

Supports standard, HART and MultiHART input address formats for device data.

Product Overview

6DL1134-6UD00-0PK0 is the SIMATIC ET 200SP HA AI 4xI 2-/4-wire HART ISOL HA module. It reads four current signals, supports HART communication and provides isolated channels for process instrumentation.

The module supports 0–20 mA and 4–20 mA ranges and uses terminal blocks of type K0 or L0. Siemens specifies L0 for a redundant module arrangement; check the station design and terminal block before ordering.

Ordering focus: confirm the exact 6UD00-0PK0 suffix, HART requirements, terminal-block type, transmitter wiring and station redundancy plan.
Key Functions

Process Current Acquisition

Converts four 0–20 mA or 4–20 mA transmitter signals for the ET 200SP HA station.

Transmitter Supply

Provides four electronically protected 24 V sensor supply outputs for connected devices.

HART Data Access

Supports HART-capable engineering with standard, HART and MultiHART address-space options.

Official Specifications
Analog Input Channels 4
Current Measuring Ranges 0–20 mA; 4–20 mA
Resolution 16 bit including sign
Input Resistance 250 Ω
Input Current Destruction Limit 24 mA
Rated Supply Voltage 24 V DC
Permissible Supply Range 19.2–28.8 V DC
Sensor Supply Outputs 4, electronically short-circuit protected
Rated Sensor Supply Voltage 24 V DC
Maximum Sensor Supply Current 23.5 mA per channel; 88 mA per module
Input Address Space 9 bytes standard; 29 bytes HART; 16 bytes MultiHART
Terminal Block Types K0 or L0; L0 for redundancy
Maximum Shielded Cable Length 800 m
Electrical Isolation 125 V AC / 150 V DC between channels, backplane and supply
Basic Error Limit ±0.1%
Operating Temperature −40 to +70 °C, subject to derating
Dimensions (W × H × D) 22.5 × 115 × 138 mm
Approximate Weight 163 g
Frequently Asked Questions

Can 6DL1134-6UD00-0PK0 connect both 2-wire and 4-wire transmitters?

Yes. The module is designated for 2-wire and 4-wire current transmitters; use the documented terminal assignments for the selected wiring.

Which current ranges are available on 6DL1134-6UD00-0PK0?

The channel measuring ranges include 0–20 mA and 4–20 mA.

Which terminal block should I specify for a redundant pair?

Siemens specifies terminal block type L0 for a redundant module arrangement; K0 is also listed for nonredundant use.

Does this module supply connected transmitters?

It provides four 24 V sensor supply outputs with electronic short-circuit protection. Check each channel and total module current limits.

How much input address space should I reserve for HART?

The manual lists 9 bytes for standard mode, 29 bytes for HART mode and 16 bytes for MultiHART mode.

Are the four measurement channels electrically isolated?

Yes. Siemens specifies isolation between channels and toward the backplane and supply.

Can I use this module in a −40 °C cabinet?

The specified operating range starts at −40 °C. Check the manual’s temperature-dependent derating and the complete station configuration.

Compatibility & Ordering Notes
Before ordering 6DL1134-6UD00-0PK0: verify sensor wiring, terminal block K0/L0, controller address configuration, environmental limits and the full ET 200SP HA station bill of materials.

ET 200SP HA integration checklist

  • Choose the matching K0 or L0 terminal block; use L0 for redundancy.
  • Set each channel to the correct current range and HART operating mode.
  • Check sensor supply current and temperature derating for the assembled station.
Hot Selling Models
KYC-25 541692
CDA225C
VSVA-B-P53ED-ZD-A2-1T1L-SA SA-244020A
3RV1011-0HA15
3RV2021-4CA15 3RV2901-1E
6ES5441-7LA12
BK3010
7NG4140-1AB20
ABB MS225 - 1.6 MS 225 690 V 1SAM151000R1006
IB120221 1865395
SL2517
2.5-PE 3044092
XB2 MD31
3TJ1022-0BB4
3RU1116-1KC1

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.