- Overview
- Hot Selling Models
- Recommended Products
Overview
- Install only SIMADYN D modules approved for the SR12 subrack format.
- Restore every module to its recorded slot and reconnect both backplane buses correctly.
- Verify fan airflow and protective grounding before applying mains power.
19:08:42Siemens · SIMADYN D
6DD1682-0BC3 SR12.3 Subrack
Siemens 6DD1682-0BC3 is the SIMADYN D SR12.3 subrack with twelve module positions, an integrated 115/230 V AC power supply and fan cooling for modular automation assemblies.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6DD1682-0BC3 |
| Product Type | Twelve-slot automation-system subrack |
| Core Function | Houses and powers SIMADYN D processor and I/O modules |
| Application or Compatible Series | SIMADYN D modular control systems |
Mains Version
Use the 115/230 V AC SR12.3 version and retain protective grounding.
Module Layout
Record the twelve-slot assignment and both backplane-bus connections.
Cooling Path
Keep the integrated fan and cabinet airflow unobstructed.
Product Overview
Siemens 6DD1682-0BC3 is the SIMADYN D SR12.3 subrack with twelve module positions, an integrated 115/230 V AC power supply and fan cooling for modular automation assemblies.
Accepts SIMADYN D modules in the documented 233.4 x 220 mm format. Feeds the installed modules through the subrack backplane buses. An integrated fan supports the thermal design of the populated rack.
Key Functions
Twelve Module Positions
Accepts SIMADYN D modules in the documented 233.4 x 220 mm format.
Integrated AC Power Supply
Feeds the installed modules through the subrack backplane buses.
Forced-Air Cooling
An integrated fan supports the thermal design of the populated rack.
Official Specifications
| Subrack Designation | SR12.3 |
|---|---|
| Module Positions | 12 |
| Input Supply | 115/230 V AC |
| Cooling Method | Integrated fan |
| Compatible Module Format | 233.4 x 220 mm |
| Backplane Distribution | L bus and C bus |
| Power-Supply Integration | Built into the subrack |
| Line-Filter Classification | VDE 0871 Class A |
| External Backup Connection | X3 |
| Supply Connection | X1 |
| Reset Interface | Front reset button or X42-13 connection |
| Power Status Indication | Green LED for normal supply |
| Fault Indication | Red LED for power-supply fault |
| Battery Access | Front backup-battery compartment |
Frequently Asked Questions
Which mains supply is required for 6DD1682-0BC3?
Use the documented 115 or 230 V AC supply with the required protective conductor.
How many modules fit in 6DD1682-0BC3?
The subrack provides twelve module positions.
Does 6DD1682-0BC3 include rack cooling?
An integrated fan provides forced-air cooling for the populated rack.
Which module size fits 6DD1682-0BC3?
Use SIMADYN D modules in the documented 233.4 x 220 mm format.
How should I document wiring before replacing 6DD1682-0BC3?
Record the X1 supply, X3 backup and all installed module positions before disassembly.
What do the front LEDs indicate on 6DD1682-0BC3?
The green indicator shows normal supply operation and the red indicator signals a power fault.
What must I inspect before commissioning 6DD1682-0BC3?
Check fan operation, grounding, backplane condition, slot assignment and the selected mains voltage.