Siemens SIMADYN D 6DD1611-0AF0 MM3 Coupling Memory Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Use only in a compatible SIMADYN D subrack and retain the documented CPU and module sequence.
- Confirm that the project requires MM3 rather than the different MM4 or MM11 coupling-memory executions.
- Back up the original configured processor connections and coupling-memory assignments.
- Verify the L-bus and C-bus configuration for every participating CPU module.
- Preserve the slot relationship between the first and second CPU modules.
- Record any shared CS7 serial-interface access before removing the existing module.
- Check the system-error relay and radio-clock integration before returning the rack to service.
Siemens · SIMADYN D
6DD1611-0AF0 MM3 Coupling Memory Module
Siemens 6DD1611-0AF0 is the SIMADYN D MM3 coupling memory module for transferring data between CPU modules in a shared subrack. It provides two 64 KB RAM areas and connects to both the L bus and C bus. The module is used when several CPUs must exchange configured data, share a coupling-memory link or access one CS7 serial interface. It also incorporates the system-error relay and radio-clock functions required by the documented SIMADYN D architecture.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6DD1611-0AF0 |
| Product Type | SIMADYN D Coupling Memory Module |
| Core Function | Provides shared RAM for data exchange between CPU modules in one subrack |
| Application or Compatible Series | SIMADYN D multi-CPU systems using L-bus and C-bus communication |
Multi-CPU Requirement
Use the module when more than one CPU in the subrack must exchange configured data or share communication resources.
Slot Arrangement
Install it in an allowed slot between the first and second CPU modules and preserve the documented rack sequence.
Project Matching
Restore the original coupling-memory connections, bus assignments and shared CS7 interface configuration before commissioning.
Product Overview
Siemens 6DD1611-0AF0 is the SIMADYN D MM3 coupling memory module for transferring data between CPU modules in a shared subrack. It provides two 64 KB RAM areas and connects to both the L bus and C bus. The module is used when several CPUs must exchange configured data, share a coupling-memory link or access one CS7 serial interface. It also incorporates the system-error relay and radio-clock functions required by the documented SIMADYN D architecture.
Two 64 KB RAM areas provide the common data space used by multiple CPU modules. The module connects to both the SIMADYN D L bus and C bus for coordinated processor communication. A system-error relay and radio-clock interface support rack-level diagnostics and time functions.
Key Functions
Dual-Bank Shared Memory
Two 64 KB RAM areas provide the common data space used by multiple CPU modules.
Backplane Bus Integration
The module connects to both the SIMADYN D L bus and C bus for coordinated processor communication.
System Coordination Functions
A system-error relay and radio-clock interface support rack-level diagnostics and time functions.
Official Specifications
| Module Designation | MM3 coupling memory |
|---|---|
| Coupling Memory Capacity | 2 x 64 KB RAM |
| Backplane Connections | L bus and C bus |
| Primary Data Role | Transfer of configured data between CPU modules |
| Configured Connection Support | Dollar-sign connections between processor modules |
| Coupling-Memory Link Support | Shared-memory coupling between processors |
| Shared Serial-Interface Use | Allows several CPUs to access a serial interface on a CS7 module |
| Documented Slot Location | Between the first and second CPU modules in the subrack |
| System Error Signaling | Integrated system-error relay function |
| Time Function | Integrated radio-clock function |
Frequently Asked Questions
When is 6DD1611-0AF0 required in a SIMADYN D rack?
Use it when multiple CPU modules must exchange configured data or share supported communication resources.
How much coupling memory does 6DD1611-0AF0 provide?
The module contains two separate 64 KB RAM areas.
Which backplane buses connect to 6DD1611-0AF0?
It interfaces with both the L bus and C bus.
Where should 6DD1611-0AF0 be positioned in the subrack?
Use an allowed slot between the first and second CPU modules while retaining the documented rack order.
Can several CPUs share a CS7 interface through 6DD1611-0AF0?
Yes, the coupling memory supports the documented arrangement in which several processors access one CS7 serial interface.
Which project data should be saved before replacing 6DD1611-0AF0?
Back up the complete SIMADYN D project and record every processor connection, memory assignment, slot and shared interface.
Does 6DD1611-0AF0 include rack-level diagnostic or timing functions?
The module provides the documented system-error relay and radio-clock functions.