Siemens APOGEE PXC Compact 24-Point BACnet Controller PXC24.2-E.A
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Product Overview
- Key Functions
- Official Specifications
- Frequently Asked Questions
- Compatibility & Ordering Notes
- Hot Selling Models
- Recommended Products
Overview
SIEMENS · APOGEE PXC Compact
PXC24.2-E.A APOGEE PXC Compact 24-Point BACnet Controller
The PXC24.2-E.A is a compact 24-point BACnet/IP building controller with integrated TX-I/O, stand-alone control logic and peer-to-peer Automation Level Network communication.
At a Glance
| Brand | Siemens |
|---|---|
| Model | PXC24.2-E.A |
| Product Type | 24-point compact building automation controller |
| Core Function | Performs stand-alone and networked HVAC control, monitoring and energy management |
| Application or Compatible Series | APOGEE BACnet/IP Automation Level Networks using integrated TX-I/O points |
Exact Identification
Match PXC24.2-E.A character by character and confirm the complete APOGEE PXC Compact 24-Point BACnet Controller designation.
Interface Arrangement
Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.
Configuration Check
Preserve the approved engineering project, network parameters and application data used by the installed system.
Product Overview
The PXC24.2-E.A is a compact 24-point BACnet/IP building controller with integrated TX-I/O, stand-alone control logic and peer-to-peer Automation Level Network communication.
The controller executes complex HVAC control, monitoring and energy-management functions without a higher-level processor. A 10/100 Mbit/s Ethernet interface connects the controller to the BACnet Automation Level Network. TX-I/O technology supports configurable analog, digital and pulse signal types across the 24-point hardware.
Key Functions
Standalone Building Control
The controller executes complex HVAC control, monitoring and energy-management functions without a higher-level processor.
Native BACnet/IP Networking
A 10/100 Mbit/s Ethernet interface connects the controller to the BACnet Automation Level Network.
Flexible Integrated I/O
TX-I/O technology supports configurable analog, digital and pulse signal types across the 24-point hardware.
Official Specifications
| Integrated Point Capacity | 24 |
|---|---|
| Processor | Freescale MPC852T at 100 MHz |
| Installed Memory | 24 MB total: 16 MB SDRAM and 8 MB Flash ROM |
| SDRAM Backup Duration | 180 accumulated days |
| SDRAM Backup Battery | AA LR6 1.5 V alkaline, field replaceable |
| Real-Time Clock Backup | 10 years with BR2032 3 V lithium coin cell |
| Analog Input Resolution | 16 bit |
| Analog Output Resolution | 10 bit |
| BACnet/IP Ethernet | 10Base-T or 100Base-TX |
| Rated Power Input | 24 V AC ±20%, 50/60 Hz |
| Maximum Power Consumption | 20 VA at 24 V AC |
| Universal Analog Inputs | 0–10 V DC, 4–20 mA and supported resistive temperature sensors |
| Universal Counter Input | Pulse accumulator up to 20 Hz |
| Universal Analog Output | 0–10 V DC |
| Dimensions | 272 x 150 x 62 mm |
| Operating Temperature | 0 to 50 °C |
| Operating Humidity | 5% to 95% RH, non-condensing |
Frequently Asked Questions
Does PXC24.2-E.A communicate directly over BACnet/IP?
Yes; the Ethernet interface supports native BACnet/IP on a 10/100 Mbit/s Automation Level Network.
Can PXC24.2-E.A control equipment without a supervisory computer?
Yes; the controller can execute stand-alone control, monitoring and energy-management programs.
How many integrated field points are available on PXC24.2-E.A?
The compact hardware provides twenty-four integrated point terminations.
Which supply is required for PXC24.2-E.A?
Use a 24 V AC source within the specified ±20 percent range at 50 or 60 Hz.
What analog conversion resolution does PXC24.2-E.A provide?
Analog inputs use 16-bit conversion and analog outputs use 10-bit conversion.
Can PXC24.2-E.A be mounted on DIN rail?
Yes; the compact controller supports the documented DIN-rail installation method.
What should be retained when replacing PXC24.2-E.A?
Preserve the BACnet address, IP settings, control database, point configuration and field wiring schedule.
Compatibility & Ordering Notes
Compatibility Checklist
- Use it on an APOGEE BACnet/IP Automation Level Network matching the installed database.
- Confirm every integrated point type and common connection before moving field wiring.
- Back up the control program, schedules, alarms and network settings before replacement.