- Confirm the DP-F PROFIBUS version and do not substitute a different fieldbus variant.
- Select a compatible PM250D Power Module for the actual motor rated power and current.
- Provide and size the external 24 V DC control supply.
- Retain the PROFIBUS address, termination and PROFIsafe parameters.
- Verify the HTL encoder wiring and repeat the required safety validation before operation.
Siemens · SINAMICS G120D
6SL3544-0FB21-1PA0 CU240D-2 DP-F Control Unit
Siemens 6SL3544-0FB21-1PA0 is the SINAMICS G120D CU240D-2 DP-F distributed drive control unit with PROFIBUS DP, PROFIsafe and integrated fail-safe motion functions; the Power Module is selected separately.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SL3544-0FB21-1PA0 |
| Product Type | SINAMICS G120D CU240D-2 DP-F Control Unit |
| Core Function | Controls distributed three-phase motor drives with integrated safety |
| Application or Compatible Series | SINAMICS G120D with a compatible PM250D Power Module |
Exact DP-F Identification
Use the PROFIBUS and PROFIsafe variant with its dedicated HTL encoder input.
Safety Architecture
Validate STO, SS1, SLS, SDI and SSM for the required SIL 2 or PL d Category 3 application.
System Assembly
Provide an external 24 V DC supply and select a PM250D Power Module for the connected motor.
Product Overview
Siemens 6SL3544-0FB21-1PA0 is the SINAMICS G120D CU240D-2 DP-F distributed drive control unit with PROFIBUS DP, PROFIsafe and integrated fail-safe motion functions; the Power Module is selected separately.
Exchanges command, status and safety data through PROFIBUS DP and PROFIsafe. Implements STO, SS1, SLS, SDI and SSM without a separate external safety controller for the drive functions. Provides configurable I/O, USB service, SD/MMC memory and an HTL encoder connection.
Key Functions
PROFIBUS Drive Control
Exchanges command, status and safety data through PROFIBUS DP and PROFIsafe.
Integrated Fail-Safe Motion
Implements STO, SS1, SLS, SDI and SSM without a separate external safety controller for the drive functions.
Local Commissioning Interfaces
Provides configurable I/O, USB service, SD/MMC memory and an HTL encoder connection.
Official Specifications
| Operating Voltage | External 24 V DC required |
|---|---|
| Current Consumption | 300 mA with FSA/FSB Power Modules; 450 mA with an FSC Power Module |
| Standard Digital Inputs | 6 |
| Fail-Safe Digital Inputs | 3 inputs can be parameterized as F-DI |
| Digital Outputs | 2 |
| Fail-Safe Digital Output | 1 output can be parameterized as F-DO |
| Analog Inputs | 2 |
| Fieldbus | PROFIBUS DP |
| Safety Communication | PROFIsafe |
| Encoder Interface | HTL |
| Service Interface | USB |
| Memory Card Interface | SD/MMC |
| Integrated Safety Functions | STO, SS1, SLS, SDI and SSM |
| Safety Rating | IEC 61508 SIL 2; ISO 13849-1 PL d, Category 3 |
| Degree of Protection | IP65 |
| Operating Temperature | 0 to +55 °C |
| Storage Conditions | −40 to +70 °C; less than 95% relative humidity without condensation |
| Dimensions and Weight | 153 × 208 × 55 mm; approximately 0.8 kg |
Frequently Asked Questions
Which power module should I pair with 6SL3544-0FB21-1PA0?
Pair the control unit with a PM250D selected for the motor rated power and current.
Which fieldbus should I prepare for 6SL3544-0FB21-1PA0?
Use PROFIBUS DP for drive communication and PROFIsafe when integrated safety functions are transferred over the bus.
Can 6SL3544-0FB21-1PA0 run without a separate control supply?
No, the control unit requires an external 24 V DC supply.
Which safety functions are available in 6SL3544-0FB21-1PA0?
The fail-safe variant provides STO, SS1, SLS, SDI and SSM.
How much fail-safe I/O does 6SL3544-0FB21-1PA0 provide?
Three of the six digital inputs and one of the two digital outputs can be parameterized for fail-safe operation.
Which motor encoder can I connect to 6SL3544-0FB21-1PA0?
Use an HTL encoder with the dedicated encoder interface.
How can I transfer commissioning data when replacing 6SL3544-0FB21-1PA0?
Save the parameter set on the supported SD/MMC card and verify the firmware and PM250D configuration before restart.