Siemens SINAMICS G120D 6SL3544-0FB21-1PA0 CU240D-2 DP-F Controlus Unitas
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Confirma versionem DP-F PROFIBUS et non substitue variantem diversam campi bus.
- Elige modulum potentiae PM250D compatibilem pro potestate nominali et currente motoris actualis.
- Praebeto et dimensio exteriorem supplitum controlis 24 V DC.
- Retine adressem PROFIBUS, terminationem et parametres PROFIsafe.
- Verifica connexionem encoderis HTL et repete validationem securitatis necessariam ante operationem.
Siemens · SINAMICS G120D
6SL3544-0FB21-1PA0 CU240D-2 DP-F Control Unit
Siemens 6SL3544-0FB21-1PA0 is the SINAMICS G120D CU240D-2 DP-F distributed drive control unit with PROFIBUS DP, PROFIsafe and integrated fail-safe motion functions; the Power Module is selected separately.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6SL3544-0FB21-1PA0 |
| Typus Producti | SINAMICS G120D CU240D-2 DP-F Control Unit |
| Functio principalis | Controls distributed three-phase motor drives with integrated safety |
| Applicatio vel series compatibiles | SINAMICS G120D with a compatible PM250D Power Module |
Exact DP-F Identification
Use the PROFIBUS and PROFIsafe variant with its dedicated HTL encoder input.
Architectura Securitatis
Validate STO, SS1, SLS, SDI and SSM for the required SIL 2 or PL d Category 3 application.
System Assembly
Provide an external 24 V DC supply and select a PM250D Power Module for the connected motor.
Product Overview
Siemens 6SL3544-0FB21-1PA0 is the SINAMICS G120D CU240D-2 DP-F distributed drive control unit with PROFIBUS DP, PROFIsafe and integrated fail-safe motion functions; the Power Module is selected separately.
Exchanges command, status and safety data through PROFIBUS DP and PROFIsafe. Implements STO, SS1, SLS, SDI and SSM without a separate external safety controller for the drive functions. Provides configurable I/O, USB service, SD/MMC memory and an HTL encoder connection.
Key Functions
PROFIBUS Drive Control
Exchanges command, status and safety data through PROFIBUS DP and PROFIsafe.
Integrated Fail-Safe Motion
Implements STO, SS1, SLS, SDI and SSM without a separate external safety controller for the drive functions.
Local Commissioning Interfaces
Provides configurable I/O, USB service, SD/MMC memory and an HTL encoder connection.
Official Specifications
| Voltage Operativum | External 24 V DC required |
|---|---|
| Consumptio currentis | 300 mA with FSA/FSB Power Modules; 450 mA with an FSC Power Module |
| Ingressus Digitales Normales | 6 |
| Fail-Safe Digital Inputs | 3 inputs can be parameterized as F-DI |
| Emissiones Digitales | 2 |
| Output Digital Securus | 1 output potest parametrari ut F-DO |
| INPUTUS ANALOGI | 2 |
| Campusbus | PROFIBUS DP |
| Communicatio Tutelaris | PROFIsafe |
| Interfacs Encoder | HTL |
| Interfacs servitii | USB |
| Interfacs Cardinae Memoriae | SD/MMC |
| Functiones Integritatis Integratae | STO, SS1, SLS, SDI et SSM |
| Censura Securitatis | IEC 61508 SIL 2; ISO 13849-1 PL d, Categoria 3 |
| Gradus praesidium | IP65 |
| Temperatura operativa | 0 ad +55 °C |
| Repono Conditions | −40 ad +70 °C; umiditas relativa minor quam 95% sine condensatione |
| Dimensiones et Pondera | 153 × 208 × 55 mm; circa 0.8 kg |
Quaestiones Frequenter Rogatae
Quod modulum potentiae cum 6SL3544-0FB21-1PA0 coniungendum est?
Coniunge unitatem de controllo cum PM250D electo pro potentia nominali motoris et currente.
Which fieldbus should I prepare for 6SL3544-0FB21-1PA0?
Use PROFIBUS DP for drive communication and PROFIsafe when integrated safety functions are transferred over the bus.
Can 6SL3544-0FB21-1PA0 run without a separate control supply?
No, the control unit requires an external 24 V DC supply.
Which safety functions are available in 6SL3544-0FB21-1PA0?
The fail-safe variant provides STO, SS1, SLS, SDI and SSM.
How much fail-safe I/O does 6SL3544-0FB21-1PA0 provide?
Three of the six digital inputs and one of the two digital outputs can be parameterized for fail-safe operation.
Which motor encoder can I connect to 6SL3544-0FB21-1PA0?
Use an HTL encoder with the dedicated encoder interface.
Quomodo possum data commissionis transferre cum 6SL3544-0FB21-1PA0 substituitur?
Salva set parametrorum in carta SD/MMC supportata et verifica firmwarum et configurationem PM250D ante reinitiationem.