Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6sl3544 0fb20 1fa0 sinamics g120d cu240d 2 pn control unit-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SINAMICS G120D 6SL3544-0FB20-1FA0 CU240D-2 PN Control Unit

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview

Siemens · SINAMICS G120D

6SL3544-0FB20-1FA0 CU240D-2 PN Control Unit

Siemens 6SL3544-0FB20-1FA0 is a SINAMICS G120D CU240D-2 PN control unit for decentralized converter systems, combining PROFINET and EtherNet/IP, local I/O, HTL feedback and integrated STO for operation with a compatible PM250D.

At a Glance

Brand Siemens
Model 6SL3544-0FB20-1FA0
Product Type Distributed Converter Control Unit
Core Function Executes decentralized motor-control commands and coordinates local field signals
Application or Compatible Series SINAMICS G120D systems with PM250D for conveyor applications

Power Module Match

Pair the control unit with a compatible PM250D selected for the connected motor because the article is supplied without a Power Module.

Network and Connector Plan

Provide external 24 V DC and verify the M12 network, I/O, encoder and power-connection arrangement.

Safety Scope

Use the standard PN execution for STO and select a PN-F variant when SS1, SLS, SDI or SSM is required.

Product Overview

Siemens 6SL3544-0FB20-1FA0 is a SINAMICS G120D CU240D-2 PN control unit for decentralized converter systems, combining PROFINET and EtherNet/IP, local I/O, HTL feedback and integrated STO for operation with a compatible PM250D.

Provides V/f, flux-current, sensorless-vector, encoder-vector and torque-control methods for decentralized drive operation. Processes field commands, two analog inputs, isolated digital outputs and bipolar HTL incremental feedback. Combines Safe Torque Off with PROFIsafe communication, a mini-USB interface and an optional SD-card slot.

Ordering focus: Distinguish the standard CU240D-2 PN from the PN-F variants and confirm the PM250D, external 24 V supply, required safety functions, network protocol, M12 connection set and HTL feedback arrangement..

Key Functions

Flexible Speed and Torque Regulation

Provides V/f, flux-current, sensorless-vector, encoder-vector and torque-control methods for decentralized drive operation.

Local I/O and Encoder Processing

Processes field commands, two analog inputs, isolated digital outputs and bipolar HTL incremental feedback.

Integrated Safety and Service Access

Combines Safe Torque Off with PROFIsafe communication, a mini-USB interface and an optional SD-card slot.

Official Specifications

Control Supply External 24 V DC required
Control-Unit Current Consumption 400 mA with PM250D frame sizes FSA and FSB; 550 mA with frame size FSC, excluding connected encoder, sensor and output loads
Digital Inputs 6 non-isolated inputs total; one fail-safe input function can be parameterized using the DI4 and DI5 two-channel pair
Digital Outputs 2 isolated outputs, 0.5 A each, supplied from switched 24 V DC
Analog Inputs 2 inputs, 0 to 10 V
Industrial Ethernet Protocols PROFINET and EtherNet/IP
Communication Profiles PROFIdrive, PROFIsafe and PROFIenergy
Encoder Interface 1 bipolar HTL incremental interface, up to 2048 pulses; no SSI interface
Motor-Temperature Input 1 input through the Power Module for PTC, KTY, bimetal or Pt1000 sensors
Mechanical Motor-Brake Control Available through the Power Module
Removable Memory Slot for optional SINAMICS SD memory card
Commissioning Interface Mini-USB
Integrated Safety Safe Torque Off, certified to IEC 61508 SIL 2 and ISO 13849-1 PL d, Category 3
Motor-Control Methods Linear, quadratic and parameterizable V/f; V/f with flux-current control; sensorless and encoder-based vector control; sensorless and encoder-based torque control
Parameter Resources 16 parameterizable fixed frequencies, 4 selectable drive data sets and 4 selectable command data sets
Positioning Function Basic positioner EPOS not included
Ambient Temperature Operation −10 to 50 °C; storage −40 to 70 °C
Relative Humidity Maximum 95% at 40 °C, non-condensing
Connection and Enclosure M12 connection design; IP65 and UL Type 3
Mechanical and Regulatory Data 153 × 208 × 55 mm; approximately 0.8 kg; UL 508C, cUL, CE and RCM

Frequently Asked Questions

Which Power Module should I pair with 6SL3544-0FB20-1FA0?

Pair the control unit with a compatible SINAMICS G120D PM250D selected for the motor and required power rating.

What external control supply does 6SL3544-0FB20-1FA0 require?

The control unit requires an external 24 V DC supply.

Can 6SL3544-0FB20-1FA0 communicate with an EtherNet/IP controller?

Yes, it supports both EtherNet/IP and PROFINET through its M12 industrial Ethernet connections.

How is the fail-safe input formed on 6SL3544-0FB20-1FA0?

Digital inputs DI4 and DI5 are evaluated as the two-channel F-DI 0 pair when the fail-safe input is parameterized.

Which motor encoder can I connect to 6SL3544-0FB20-1FA0?

The control unit accepts bipolar HTL incremental feedback up to 2048 pulses and does not provide an SSI encoder interface.

Can 6SL3544-0FB20-1FA0 run an onboard positioning function?

No, the CU240D-2 PN does not include the EPOS basic positioner.

What integrated safety scope does 6SL3544-0FB20-1FA0 provide?

The standard PN control unit provides STO, while SS1, SLS, SDI and SSM require a fail-safe PN-F variant.

Compatibility & Ordering Notes

Before ordering 6SL3544-0FB20-1FA0: Distinguish the standard CU240D-2 PN from the PN-F variants and confirm the PM250D, external 24 V supply, required safety functions, network protocol, M12 connection set and HTL feedback arrangement..

Compatibility Checklist

  • Pair the control unit with a compatible PM250D selected for the connected motor and required converter rating.
  • Provide an external 24 V DC supply and account for the control-unit, sensor, encoder and output-current demand.
  • Use the correct M12 connectors and cable layout for PROFINET or EtherNet/IP, power, I/O and HTL feedback.
  • Confirm that STO alone meets the machine risk assessment; select 6SL3544-0FB21-1FA0 or another appropriate fail-safe variant if extended safety functions are required.
  • Wire DI4 and DI5 as a two-channel pair when using the fail-safe input.
  • Confirm that analog signals are 0 to 10 V and that output loads stay within the isolated 0.5 A channel ratings.
  • Use an HTL incremental encoder; do not specify an SSI absolute encoder for this control unit.
  • Select a suitable SINAMICS SD card separately if removable parameter storage is required.
  • Confirm the installed firmware, engineering-tool version, telegram profile and controller project before replacement.
  • Maintain the specified connector and sealing arrangement when IP65 protection is required.
Hot Selling Models
7000-88041-6300300
3RV2901-2B
PSR-SPP-24DC/URM4/4X1/2X2/B
IME08-04NPSZT0K
Di-Soric DCC 08 M 1.5 POK-IBSL
IME08-1B5PSZT0K
162810
ZK2020-3132-0003
A5E00174509A
Allen Bradley 1492-SP1C060
VSVA-B-T32C-AZD-A2-1T1L
3WL9111-0AH11-0AA0
3RH2911-1GA31
8US1260-5AP00
3RV2011-1EA15

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.