Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6se7090 0xx84 0ab0 simovert masterdrives cuvc vector control unit-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIMOVERT MASTERDRIVES 6SE7090-0XX84-0AB0 CUVC Vector Control Unit

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview

Siemens · SIMOVERT MASTERDRIVES Vector Control

6SE7090-0XX84-0AB0 CUVC Control Unit Vector Control

Siemens 6SE7090-0XX84-0AB0 is the CUVC Control Unit Vector Control for the SIMOVERT MASTERDRIVES product family. It combines drive-control processing with digital and analog control terminals, serial communication, HTL pulse-encoder feedback and motor-temperature evaluation. The control unit is used as the central control board in a compatible MASTERDRIVES converter. Replacement requires preservation of the drive parameter set and verification of the X101, X102 and X103 terminal allocation because CUVC signal assignments differ from earlier CU2 hardware.

At a Glance

Brand Siemens
Model 6SE7090-0XX84-0AB0
Product Type Vector Control Unit
Core Function Executes open-loop and closed-loop vector control for a SIMOVERT MASTERDRIVES converter
Application or Compatible Series SIMOVERT MASTERDRIVES Vector Control drive systems

Exact Control Board

Match the complete 0AB0 article number and the CUVC Vector Control function before exchanging the board.

Terminal Migration

Record X101, X102 and X103 wiring because CU2 and CUVC terminals are not a position-for-position match.

Parameter Recovery

Back up the drive parameter set and verify BICO, analog-range, encoder and temperature-sensor settings before removal.

Product Overview

Siemens 6SE7090-0XX84-0AB0 is the CUVC Control Unit Vector Control for the SIMOVERT MASTERDRIVES product family. It combines drive-control processing with digital and analog control terminals, serial communication, HTL pulse-encoder feedback and motor-temperature evaluation. The control unit is used as the central control board in a compatible MASTERDRIVES converter. Replacement requires preservation of the drive parameter set and verification of the X101, X102 and X103 terminal allocation because CUVC signal assignments differ from earlier CU2 hardware.

Provides the central open-loop and closed-loop control functions for compatible MASTERDRIVES Vector Control converters. Handles digital I/O, two analog input channels, two analog output channels and serial communication on the base board. Accepts unipolar HTL pulse-encoder signals and either PTC or KTY84 motor-temperature feedback.

Ordering focus: Confirm the complete CUVC article number, installed MASTERDRIVES power section, board hardware state, firmware and saved parameter set; document every X101, X102 and X103 connection before exchange..

Key Functions

Vector Drive Control

Provides the central open-loop and closed-loop control functions for compatible MASTERDRIVES Vector Control converters.

Integrated Signal Interfaces

Handles digital I/O, two analog input channels, two analog output channels and serial communication on the base board.

Motor Feedback Processing

Accepts unipolar HTL pulse-encoder signals and either PTC or KTY84 motor-temperature feedback.

Official Specifications

Service Communication RS232 or RS485 serial interface for a PC or OP1S operator panel
USS Interface Second serial interface on X101 using two-wire RS485; four-wire USS is not supported
Auxiliary 24 V Output 24 V DC, maximum 150 mA at X101 terminals 1 and 2
Bidirectional Digital Channels DIO1 to DIO4 on X101 terminals 3 to 6
Dedicated Digital Inputs DI5 to DI7 on X101 terminals 7 to 9
Digital Output Characteristic SIMATIC-compatible; floating digital outputs require an EB2 extension board
Analog Reference Supplies +10 V and -10 V, 5 mA each at X102 terminals 13 and 14
Analog Input Quantity 2 channels at X102 terminals 15/16 and 17/18
Analog Input Ranges Selectable ±10 V or ±20 mA
Analog Input Evaluation Bipolar, unipolar or 4 to 20 mA
Current-Loop Diagnostics Wire-break monitoring can be activated for 4 to 20 mA evaluation
Analog Output Quantity 2 channels at X102 terminals 19/20 and 21/22
Analog Output Ranges Selectable ±10 V or 0 to 20 mA
Encoder Interface Unipolar HTL pulse encoder with A track, B track, zero track and monitoring signal on X103
Encoder Supply 15 V DC, maximum 150 mA at X103 terminal 28
Motor Temperature Sensor PTC or KTY84 input on X103 terminals 29 and 30
BICO Data Sets 2 selectable BICO data sets
Floating Changeover Output Requires an EB2 extension board

Frequently Asked Questions

Can 6SE7090-0XX84-0AB0 use the same terminal positions as an older CU2 board?

No, the CU2-to-CUVC conversion requires terminal reassignment and a parameter review rather than position-for-position rewiring.

Which encoder can I connect to 6SE7090-0XX84-0AB0?

Use a unipolar HTL pulse encoder with A, B, zero and monitoring signals and stay within the 15 V 150 mA supply limit.

Which analog input ranges are available on 6SE7090-0XX84-0AB0?

Each analog input can be switched for ±10 V or ±20 mA and evaluated as bipolar, unipolar or 4 to 20 mA.

Can 6SE7090-0XX84-0AB0 detect a broken 4 to 20 mA input loop?

Yes, wire-break monitoring can be activated when the channel is configured for 4 to 20 mA evaluation.

Which motor temperature sensors work with 6SE7090-0XX84-0AB0?

The motor-temperature input accepts either a PTC or a KTY84 sensor with the corresponding parameter setting.

Does 6SE7090-0XX84-0AB0 support four-wire USS communication?

No, the onboard USS interface uses two-wire RS485 and does not support four-wire USS.

When does 6SE7090-0XX84-0AB0 require an EB2 extension board?

Use an EB2 when the application needs floating digital outputs or a floating relay changeover contact.

Compatibility & Ordering Notes

Before ordering 6SE7090-0XX84-0AB0: Confirm the complete CUVC article number, installed MASTERDRIVES power section, board hardware state, firmware and saved parameter set; document every X101, X102 and X103 connection before exchange..

Compatibility Checklist

  • Use only in a converter platform designed for the SIMOVERT MASTERDRIVES CUVC control unit.
  • Back up and compare the complete drive parameter set before removing the existing board.
  • Map CU2 wiring to the CUVC terminal designations instead of transferring conductors by terminal number.
  • Check all X101 digital and RS485 functions against the installed circuit.
  • Set the X102 switches and parameters for the actual voltage or current signal ranges.
  • Confirm encoder signal type, track assignment and the 15 V 150 mA supply limit.
  • Select PTC or KTY84 evaluation to match the connected motor sensor.
  • Add EB2 only when floating outputs or a relay changeover contact are required.
  • Restore BICO assignments and verify both data sets before returning the drive to service.
Hot Selling Models
3RV2902-1AP0
3RV2011-0KA10 3RV2901-1E
3RA2921-2AA00
7000-74701-7770100
BAUM4SLX7 45-85-10/8
37201 CT1-250-1
3UA5200-0K
ABB NFZ31E
3TX7014-1BB00
3RV2011-1HA15
3RV1011-0CA10 3RV1901-1E
3SB3801-2AB3
NBB20-L2-A2-C-V1
5SX43 C3 5SX4
A221-600 CH10

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.