Siemens SIMOVERT MASTERDRIVES 6SE7090-0XX84-0AB0 CUVC Vector Control Unit
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Use only in a converter platform designed for the SIMOVERT MASTERDRIVES CUVC control unit.
- Back up and compare the complete drive parameter set before removing the existing board.
- Map CU2 wiring to the CUVC terminal designations instead of transferring conductors by terminal number.
- Check all X101 digital and RS485 functions against the installed circuit.
- Set the X102 switches and parameters for the actual voltage or current signal ranges.
- Confirm encoder signal type, track assignment and the 15 V 150 mA supply limit.
- Select PTC or KTY84 evaluation to match the connected motor sensor.
- Add EB2 only when floating outputs or a relay changeover contact are required.
- Restore BICO assignments and verify both data sets before returning the drive to service.
Siemens · SIMOVERT MASTERDRIVES Vector Control
6SE7090-0XX84-0AB0 CUVC Control Unit Vector Control
Siemens 6SE7090-0XX84-0AB0 is the CUVC Control Unit Vector Control for the SIMOVERT MASTERDRIVES product family. It combines drive-control processing with digital and analog control terminals, serial communication, HTL pulse-encoder feedback and motor-temperature evaluation. The control unit is used as the central control board in a compatible MASTERDRIVES converter. Replacement requires preservation of the drive parameter set and verification of the X101, X102 and X103 terminal allocation because CUVC signal assignments differ from earlier CU2 hardware.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SE7090-0XX84-0AB0 |
| Product Type | Vector Control Unit |
| Core Function | Executes open-loop and closed-loop vector control for a SIMOVERT MASTERDRIVES converter |
| Application or Compatible Series | SIMOVERT MASTERDRIVES Vector Control drive systems |
Exact Control Board
Match the complete 0AB0 article number and the CUVC Vector Control function before exchanging the board.
Terminal Migration
Record X101, X102 and X103 wiring because CU2 and CUVC terminals are not a position-for-position match.
Parameter Recovery
Back up the drive parameter set and verify BICO, analog-range, encoder and temperature-sensor settings before removal.
Product Overview
Siemens 6SE7090-0XX84-0AB0 is the CUVC Control Unit Vector Control for the SIMOVERT MASTERDRIVES product family. It combines drive-control processing with digital and analog control terminals, serial communication, HTL pulse-encoder feedback and motor-temperature evaluation. The control unit is used as the central control board in a compatible MASTERDRIVES converter. Replacement requires preservation of the drive parameter set and verification of the X101, X102 and X103 terminal allocation because CUVC signal assignments differ from earlier CU2 hardware.
Provides the central open-loop and closed-loop control functions for compatible MASTERDRIVES Vector Control converters. Handles digital I/O, two analog input channels, two analog output channels and serial communication on the base board. Accepts unipolar HTL pulse-encoder signals and either PTC or KTY84 motor-temperature feedback.
Key Functions
Vector Drive Control
Provides the central open-loop and closed-loop control functions for compatible MASTERDRIVES Vector Control converters.
Integrated Signal Interfaces
Handles digital I/O, two analog input channels, two analog output channels and serial communication on the base board.
Motor Feedback Processing
Accepts unipolar HTL pulse-encoder signals and either PTC or KTY84 motor-temperature feedback.
Official Specifications
| Service Communication | RS232 or RS485 serial interface for a PC or OP1S operator panel |
|---|---|
| USS Interface | Second serial interface on X101 using two-wire RS485; four-wire USS is not supported |
| Auxiliary 24 V Output | 24 V DC, maximum 150 mA at X101 terminals 1 and 2 |
| Bidirectional Digital Channels | DIO1 to DIO4 on X101 terminals 3 to 6 |
| Dedicated Digital Inputs | DI5 to DI7 on X101 terminals 7 to 9 |
| Digital Output Characteristic | SIMATIC-compatible; floating digital outputs require an EB2 extension board |
| Analog Reference Supplies | +10 V and -10 V, 5 mA each at X102 terminals 13 and 14 |
| Analog Input Quantity | 2 channels at X102 terminals 15/16 and 17/18 |
| Analog Input Ranges | Selectable ±10 V or ±20 mA |
| Analog Input Evaluation | Bipolar, unipolar or 4 to 20 mA |
| Current-Loop Diagnostics | Wire-break monitoring can be activated for 4 to 20 mA evaluation |
| Analog Output Quantity | 2 channels at X102 terminals 19/20 and 21/22 |
| Analog Output Ranges | Selectable ±10 V or 0 to 20 mA |
| Encoder Interface | Unipolar HTL pulse encoder with A track, B track, zero track and monitoring signal on X103 |
| Encoder Supply | 15 V DC, maximum 150 mA at X103 terminal 28 |
| Motor Temperature Sensor | PTC or KTY84 input on X103 terminals 29 and 30 |
| BICO Data Sets | 2 selectable BICO data sets |
| Floating Changeover Output | Requires an EB2 extension board |
Frequently Asked Questions
Can 6SE7090-0XX84-0AB0 use the same terminal positions as an older CU2 board?
No, the CU2-to-CUVC conversion requires terminal reassignment and a parameter review rather than position-for-position rewiring.
Which encoder can I connect to 6SE7090-0XX84-0AB0?
Use a unipolar HTL pulse encoder with A, B, zero and monitoring signals and stay within the 15 V 150 mA supply limit.
Which analog input ranges are available on 6SE7090-0XX84-0AB0?
Each analog input can be switched for ±10 V or ±20 mA and evaluated as bipolar, unipolar or 4 to 20 mA.
Can 6SE7090-0XX84-0AB0 detect a broken 4 to 20 mA input loop?
Yes, wire-break monitoring can be activated when the channel is configured for 4 to 20 mA evaluation.
Which motor temperature sensors work with 6SE7090-0XX84-0AB0?
The motor-temperature input accepts either a PTC or a KTY84 sensor with the corresponding parameter setting.
Does 6SE7090-0XX84-0AB0 support four-wire USS communication?
No, the onboard USS interface uses two-wire RS485 and does not support four-wire USS.
When does 6SE7090-0XX84-0AB0 require an EB2 extension board?
Use an EB2 when the application needs floating digital outputs or a floating relay changeover contact.